1
-
-
77955329664
-
Numerical simulation of natural ventilation of a factory roof cavity
-
L. Susanti, H. Homma, H. Matsumoto, Y. Suzuki, and M. Shimizu Numerical simulation of natural ventilation of a factory roof cavity Energy and Buildings 42 2010 1337 1343
-
(2010)
Energy and Buildings
, vol.42
, pp. 1337-1343
-
-
Susanti, L.1
Homma, H.2
Matsumoto, H.3
Suzuki, Y.4
Shimizu, M.5
-
2
-
-
0036568468
-
Effect of passive techniques on interior temperature in small houses in the dry, hot climate of northwestern Mexico
-
M.A.P. Gandara, E. Rubio, J.L. Fernandez, and V.G. Munoz Effect of passive techniques on interior temperature in small houses in the dry, hot climate of northwestern Mexico Renewable Energy 26 2002 121 135
-
(2002)
Renewable Energy
, vol.26
, pp. 121-135
-
-
Gandara, M.A.P.1
Rubio, E.2
Fernandez, J.L.3
Munoz, V.G.4
-
3
-
-
27744548574
-
Passive cooling in a low-energy office building
-
H Breesch, A. Bossaer, and A. Janssens Passive cooling in a low-energy office building Solar Energy 79 2005 682 696
-
(2005)
Solar Energy
, vol.79
, pp. 682-696
-
-
Breesch, H.1
Bossaer, A.2
Janssens, A.3
-
4
-
-
0032662952
-
Heat and moisture response of vented and compact cathedral ceilings; A test house evaluation
-
H. Hens, and A. Janssens Heat and moisture response of vented and compact cathedral ceilings; a test house evaluation ASHRAE Transactions 105 1 1999 837 850
-
(1999)
ASHRAE Transactions
, vol.105
, Issue.1
, pp. 837-850
-
-
Hens, H.1
Janssens, A.2
-
5
-
-
78049482571
-
-
Florida Solar Energy Center, Cape Canaveral, FL
-
P. Fairey, M. Swami, D. Beal, RBS Technology: Task 3 Report, DOE# DE-FC03-86SF16305, Florida Solar Energy Center, Cape Canaveral, FL, 1998.
-
(1998)
RBS Technology: Task 3 Report, DOE# DE-FC03-86SF16305
-
-
Fairey, P.1
Swami, M.2
Beal, D.3
-
6
-
-
0032308858
-
Instrumentation and measurement of airflow and temperature in Attics fitted with ridge and soffit vents
-
M.I. Romero, and R.J. Brenner Instrumentation and measurement of airflow and temperature in Attics fitted with ridge and soffit vents ASHRAE Transactions: Symposia 17 1998 1074 1083
-
(1998)
ASHRAE Transactions: Symposia
, vol.17
, pp. 1074-1083
-
-
Romero, M.I.1
Brenner, R.J.2
-
8
-
-
52149119850
-
A laboratory experiment on natural ventilation through a roof cavity for reduction of solar heat gain
-
L. Susanti, H. Homma, H. Matsumoto, Y. Suzuki, and M. Shimizu A laboratory experiment on natural ventilation through a roof cavity for reduction of solar heat gain Energy and Buildings 40 2008 2196 2206
-
(2008)
Energy and Buildings
, vol.40
, pp. 2196-2206
-
-
Susanti, L.1
Homma, H.2
Matsumoto, H.3
Suzuki, Y.4
Shimizu, M.5
-
9
-
-
0012037732
-
-
ASHRAE American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc Atlanta
-
ASHRAE Handbook - Fundamentals 2005 American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc Atlanta Ch. 25, Ch. 31, Ch. 39
-
(2005)
Handbook - Fundamentals
-
-
-
14
-
-
0003632802
-
-
ANSI/ASHRAE Standard 55-1992 American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. Atlanta
-
ANSI/ASHRAE Standard 55-1992 Thermal environmental conditions for human occupancy 1992 American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. Atlanta
-
(1992)
Thermal Environmental Conditions for Human Occupancy
-
-
|