메뉴 건너뛰기




Volumn 43, Issue 1, 2011, Pages 211-218

A naturally ventilated cavity roof as potential benefits for improving thermal environment and cooling load of a factory building

Author keywords

Cavity roof; Cooling load; Energy saving; Natural ventilation; Operative temperature

Indexed keywords

CAVITY ROOF; COOLING LOAD; ENERGY SAVING; NATURAL VENTILATION; OPERATIVE TEMPERATURE;

EID: 78049463430     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2010.09.009     Document Type: Article
Times cited : (44)

References (14)
  • 2
    • 0036568468 scopus 로고    scopus 로고
    • Effect of passive techniques on interior temperature in small houses in the dry, hot climate of northwestern Mexico
    • M.A.P. Gandara, E. Rubio, J.L. Fernandez, and V.G. Munoz Effect of passive techniques on interior temperature in small houses in the dry, hot climate of northwestern Mexico Renewable Energy 26 2002 121 135
    • (2002) Renewable Energy , vol.26 , pp. 121-135
    • Gandara, M.A.P.1    Rubio, E.2    Fernandez, J.L.3    Munoz, V.G.4
  • 3
    • 27744548574 scopus 로고    scopus 로고
    • Passive cooling in a low-energy office building
    • H Breesch, A. Bossaer, and A. Janssens Passive cooling in a low-energy office building Solar Energy 79 2005 682 696
    • (2005) Solar Energy , vol.79 , pp. 682-696
    • Breesch, H.1    Bossaer, A.2    Janssens, A.3
  • 4
    • 0032662952 scopus 로고    scopus 로고
    • Heat and moisture response of vented and compact cathedral ceilings; A test house evaluation
    • H. Hens, and A. Janssens Heat and moisture response of vented and compact cathedral ceilings; a test house evaluation ASHRAE Transactions 105 1 1999 837 850
    • (1999) ASHRAE Transactions , vol.105 , Issue.1 , pp. 837-850
    • Hens, H.1    Janssens, A.2
  • 6
    • 0032308858 scopus 로고    scopus 로고
    • Instrumentation and measurement of airflow and temperature in Attics fitted with ridge and soffit vents
    • M.I. Romero, and R.J. Brenner Instrumentation and measurement of airflow and temperature in Attics fitted with ridge and soffit vents ASHRAE Transactions: Symposia 17 1998 1074 1083
    • (1998) ASHRAE Transactions: Symposia , vol.17 , pp. 1074-1083
    • Romero, M.I.1    Brenner, R.J.2
  • 8
    • 52149119850 scopus 로고    scopus 로고
    • A laboratory experiment on natural ventilation through a roof cavity for reduction of solar heat gain
    • L. Susanti, H. Homma, H. Matsumoto, Y. Suzuki, and M. Shimizu A laboratory experiment on natural ventilation through a roof cavity for reduction of solar heat gain Energy and Buildings 40 2008 2196 2206
    • (2008) Energy and Buildings , vol.40 , pp. 2196-2206
    • Susanti, L.1    Homma, H.2    Matsumoto, H.3    Suzuki, Y.4    Shimizu, M.5
  • 9
    • 0012037732 scopus 로고    scopus 로고
    • ASHRAE American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc Atlanta
    • ASHRAE Handbook - Fundamentals 2005 American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc Atlanta Ch. 25, Ch. 31, Ch. 39
    • (2005) Handbook - Fundamentals
  • 14
    • 0003632802 scopus 로고
    • ANSI/ASHRAE Standard 55-1992 American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. Atlanta
    • ANSI/ASHRAE Standard 55-1992 Thermal environmental conditions for human occupancy 1992 American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. Atlanta
    • (1992) Thermal Environmental Conditions for Human Occupancy


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.