메뉴 건너뛰기




Volumn 398, Issue 5, 2010, Pages 1871-1881

A hard microflow cytometer using groove-generated sheath flow for multiplexed bead and cell assays

Author keywords

Flow cytometry; Hydrodynamic focusing; Microflow cytometer

Indexed keywords

CANCER CELLS; CELL ASSAYS; FLUORESCENCE IN SITU HYBRIDIZATION; HYDRODYNAMIC FOCUSING; LOCKED NUCLEIC ACID; MICRO-PARTICLES; MICROFLOW CYTOMETER; MICROMACHINED; OPTICAL DETECTION; SHEATH FLOWS;

EID: 78049351588     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-010-4019-7     Document Type: Article
Times cited : (28)

References (19)
  • 1
    • 1542724638 scopus 로고    scopus 로고
    • The evolution of cytometers
    • 10.1002/cyto.a.10111
    • HM Shapiro 2004 The evolution of cytometers Cytom A 58A 1 13 20 10.1002/cyto.a.10111
    • (2004) Cytom A , vol.58 , Issue.1 , pp. 13-20
    • Shapiro, H.M.1
  • 2
    • 78049328012 scopus 로고    scopus 로고
    • A history of flow cytometry and sorting
    • Shapiro H ed ed. F.S.L.a.J.S. Kim., Pan Stanford: Singapore
    • Shapiro H ed (2010) A history of flow cytometry and sorting. The microflow cytometer ed. F.S.L.a.J.S. Kim., Pan Stanford: Singapore. 1-24
    • (2010) The Microflow Cytometer , pp. 1-24
  • 3
    • 45849117984 scopus 로고    scopus 로고
    • The good, the bad, and the tiny: A review of microflow cytometry
    • 1:CAS:528:DC%2BD1cXnsFaktL0%3D 10.1007/s00216-007-1827-5
    • DA Ateya, et al. 2008 The good, the bad, and the tiny: a review of microflow cytometry Anal Bioanal Chem 391 5 1485 1498 1:CAS:528: DC%2BD1cXnsFaktL0%3D 10.1007/s00216-007-1827-5
    • (2008) Anal Bioanal Chem , vol.391 , Issue.5 , pp. 1485-1498
    • Ateya, D.A.1
  • 4
    • 67649933627 scopus 로고    scopus 로고
    • Multi-wavelength microflow cytometer using groove-generated sheath flow
    • 1:CAS:528:DC%2BD1MXnt1ygu7g%3D 10.1039/b822442k
    • JP Golden, et al. 2009 Multi-wavelength microflow cytometer using groove-generated sheath flow Lab Chip 9 13 1942 1950 1:CAS:528: DC%2BD1MXnt1ygu7g%3D 10.1039/b822442k
    • (2009) Lab Chip , vol.9 , Issue.13 , pp. 1942-1950
    • Golden, J.P.1
  • 5
    • 0242385640 scopus 로고    scopus 로고
    • Microfluidic devices for the high-throughput chemical analysis of cells
    • 1:CAS:528:DC%2BD3sXnsVOisr4%3D 10.1021/ac0346510
    • MA McClain, et al. 2003 Microfluidic devices for the high-throughput chemical analysis of cells Anal Chem 75 21 5646 5655 1:CAS:528: DC%2BD3sXnsVOisr4%3D 10.1021/ac0346510
    • (2003) Anal Chem , vol.75 , Issue.21 , pp. 5646-5655
    • McClain, M.A.1
  • 6
    • 0032030261 scopus 로고    scopus 로고
    • Modular concept of a laboratory on a chip for chemical and biochemical analysis
    • 1:CAS:528:DyaK1cXjs1Kkuro%3D 10.1016/S0956-5663(97)00109-7
    • G Blankenstein UD Larsen 1998 Modular concept of a laboratory on a chip for chemical and biochemical analysis Biosens Bioelectron 13 3-4 427 438 1:CAS:528:DyaK1cXjs1Kkuro%3D 10.1016/S0956-5663(97)00109-7
    • (1998) Biosens Bioelectron , vol.13 , Issue.34 , pp. 427-438
    • Blankenstein, G.1    Larsen, U.D.2
  • 7
    • 0033214875 scopus 로고    scopus 로고
    • Microchip flow cytometry using electrokinetic focusing
    • 1:CAS:528:DyaK1MXkvFWmt7Y%3D 10.1021/ac990372u
    • DP Schrum, et al. 1999 Microchip flow cytometry using electrokinetic focusing Anal Chem 71 19 4173 4177 1:CAS:528:DyaK1MXkvFWmt7Y%3D 10.1021/ac990372u
    • (1999) Anal Chem , vol.71 , Issue.19 , pp. 4173-4177
    • Schrum, D.P.1
  • 8
    • 46149084671 scopus 로고    scopus 로고
    • Two simple and rugged designs for creating microfluidic sheath flow
    • 1:CAS:528:DC%2BD1cXnvFehsr0%3D 10.1039/b719381e
    • PB Howell Jr, et al. 2008 Two simple and rugged designs for creating microfluidic sheath flow Lab Chip 8 7 1097 1103 1:CAS:528:DC%2BD1cXnvFehsr0%3D 10.1039/b719381e
    • (2008) Lab Chip , vol.8 , Issue.7 , pp. 1097-1103
    • Howell Jr., P.B.1
  • 9
    • 67649933627 scopus 로고    scopus 로고
    • Multi-wavelength microflow cytometer using groove-generated sheath flow
    • 1:CAS:528:DC%2BD1MXnt1ygu7g%3D 10.1039/b822442k
    • JP Golden, et al. 2009 Multi-wavelength microflow cytometer using groove-generated sheath flow Lab Chip 9 1942 1950 1:CAS:528:DC%2BD1MXnt1ygu7g%3D 10.1039/b822442k
    • (2009) Lab Chip , vol.9 , pp. 1942-1950
    • Golden, J.P.1
  • 10
    • 67649997689 scopus 로고    scopus 로고
    • Multiplexed detection of bacteria and toxins using a microflow cytometer
    • 1:CAS:528:DC%2BD1MXmvVemtLo%3D 10.1021/ac9005827
    • JS Kim, et al. 2009 Multiplexed detection of bacteria and toxins using a microflow cytometer Anal Chem 81 13 5426 5432 1:CAS:528:DC%2BD1MXmvVemtLo%3D 10.1021/ac9005827
    • (2009) Anal Chem , vol.81 , Issue.13 , pp. 5426-5432
    • Kim, J.S.1
  • 11
    • 78049330412 scopus 로고    scopus 로고
    • Laser-based fabrication of microflow cytometers with integrated optical waveguides
    • F.S.L.a.K.S. Kim Editor, Pan Stanford: Singapore
    • Dugan M, Said AA, Haddock T, Bado P, BellouardY (2010) Laser-based fabrication of microflow cytometers with integrated optical waveguides, in The Microflow Cytometer, F.S.L.a.K.S. Kim Editor, Pan Stanford: Singapore p. 287-310
    • (2010) The Microflow Cytometer , pp. 287-310
    • Dugan, M.1    Said, A.A.2    Haddock, T.3    Bado, P.4    Bellouard, Y.5
  • 12
    • 62649119668 scopus 로고    scopus 로고
    • Microfluidic structures for flow cytometric analysis of hydrodynamically focussed blood cells fabricated by ultraprecision micromachining
    • 1:CAS:528:DC%2BD1MXjt1amtb8%3D 10.1039/b808336c
    • A Kummrow, et al. 2009 Microfluidic structures for flow cytometric analysis of hydrodynamically focussed blood cells fabricated by ultraprecision micromachining Lab Chip 9 7 972 981 1:CAS:528:DC%2BD1MXjt1amtb8%3D 10.1039/b808336c
    • (2009) Lab Chip , vol.9 , Issue.7 , pp. 972-981
    • Kummrow, A.1
  • 13
    • 70449534820 scopus 로고    scopus 로고
    • An integrated flow-cell for full sample stream control
    • 1:CAS:528:DC%2BD1MXhsVSmurbO 10.1007/s10404-009-0425-6
    • G Hairer MJ Vellekoop 2009 An integrated flow-cell for full sample stream control Microfluid Nanofluid 7 5 647 658 1:CAS:528:DC%2BD1MXhsVSmurbO 10.1007/s10404-009-0425-6
    • (2009) Microfluid Nanofluid , vol.7 , Issue.5 , pp. 647-658
    • Hairer, G.1    Vellekoop, M.J.2
  • 14
    • 42149157199 scopus 로고    scopus 로고
    • Cell analysis in a microfluidic cytorneter applying a DVD pickup head
    • 10.1016/j.snb.2007.11.038
    • S Kostner M Vellekoop 2008 Cell analysis in a microfluidic cytorneter applying a DVD pickup head Sens Actuators, B 132 2 512 517 10.1016/j.snb.2007. 11.038
    • (2008) Sens Actuators, B , vol.132 , Issue.2 , pp. 512-517
    • Kostner, S.1    Vellekoop, M.2
  • 15
    • 0033485341 scopus 로고    scopus 로고
    • Design and first results of CytoBuoy: A wireless flow cytometer for in situ analysis of marine and fresh waters
    • 1:STN:280:DC%2BD3c%2Fhs1ehsw%3D%3D 10.1002/(SICI)1097-0320(19991 201)37:4<247::AID-CYTO1>3.0.CO;2-9
    • GBJ Dubelaar, et al. 1999 Design and first results of CytoBuoy: a wireless flow cytometer for in situ analysis of marine and fresh waters Cytometry 37 4 247 254 1:STN:280:DC%2BD3c%2Fhs1ehsw%3D%3D 10.1002/(SICI)1097- 0320(19991201)37:4<247::AID-CYTO1>3.0.CO;2-9
    • (1999) Cytometry , vol.37 , Issue.4 , pp. 247-254
    • Dubelaar, G.B.J.1
  • 16
    • 0141924335 scopus 로고    scopus 로고
    • Fine-scale variability in phytoplankton community structure and inherent optical properties measured from an autonomous underwater vehicle
    • 10.1016/S0924-7963(03)00088-5
    • A Cunningham, et al. 2003 Fine-scale variability in phytoplankton community structure and inherent optical properties measured from an autonomous underwater vehicle J Mar Syst 43 1-2 51 59 10.1016/S0924-7963(03)00088-5
    • (2003) J Mar Syst , vol.43 , Issue.12 , pp. 51-59
    • Cunningham, A.1
  • 17
    • 77949615407 scopus 로고    scopus 로고
    • Sub meso scale phytoplankton distribution in the North East Atlantic surface waters determined with an automated flow cytometer
    • 1:CAS:528:DC%2BD1MXnvVOmtbk%3D 10.5194/bg-6-569-2009
    • M Thyssen N Garcia M Denis 2009 Sub meso scale phytoplankton distribution in the North East Atlantic surface waters determined with an automated flow cytometer Biogeosciences 6 4 569 583 1:CAS:528:DC%2BD1MXnvVOmtbk%3D 10.5194/bg-6-569-2009
    • (2009) Biogeosciences , vol.6 , Issue.4 , pp. 569-583
    • Thyssen, M.1    Garcia, N.2    Denis, M.3
  • 18
    • 67349155946 scopus 로고    scopus 로고
    • LNA flow-FISH: A flow cytometry-fluorescence in situ hybridization method to detect messenger RNA using locked nucleic acid probes
    • 1:CAS:528:DC%2BD1MXms1Onu78%3D 10.1016/j.ab.2009.04.026
    • KL Robertson DC Thach 2009 LNA flow-FISH: a flow cytometry-fluorescence in situ hybridization method to detect messenger RNA using locked nucleic acid probes Anal Biochem 390 2 109 114 1:CAS:528:DC%2BD1MXms1Onu78%3D 10.1016/j.ab.2009.04.026
    • (2009) Anal Biochem , vol.390 , Issue.2 , pp. 109-114
    • Robertson, K.L.1    Thach, D.C.2
  • 19
    • 34548852722 scopus 로고    scopus 로고
    • Flow cytometry and FISH to measure the average length of telomeres (flow FISH)
    • 1:CAS:528:DC%2BD2sXhtFGjtLbL 10.1038/nprot.2006.263
    • GM Baerlocher, et al. 2006 Flow cytometry and FISH to measure the average length of telomeres (flow FISH) Nat Protoc 1 5 2365 2376 1:CAS:528: DC%2BD2sXhtFGjtLbL 10.1038/nprot.2006.263
    • (2006) Nat Protoc , vol.1 , Issue.5 , pp. 2365-2376
    • Baerlocher, G.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.