메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Motion artifact removal from muscle NIR Spectroscopy measurements

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFACT REMOVAL; FIR FILTERING; FREE REGION; MEDIAN FILTERING; MOTION ARTIFACT; MOVEMENT ARTIFACTS; NIR SPECTROSCOPY; OPTICAL METHODS; SIGNAL REPRESENTATIONS; STATISTICAL TESTING; THRESHOLD ESTIMATION; TISSUE OXYGENATION; WAVELET DOMAIN;

EID: 78049345259     PISSN: 08407789     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CCECE.2010.5575241     Document Type: Conference Paper
Times cited : (10)

References (12)
  • 1
    • 0017571334 scopus 로고
    • Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • December
    • F. F. Jobsis, "Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters, " Science, vol. 198, pp. 1264-1267, December 1977.
    • (1977) Science , vol.198 , pp. 1264-1267
    • Jobsis, F.F.1
  • 3
    • 33847100365 scopus 로고    scopus 로고
    • Applications of functional nearinfrared spectroscopy (fnirs) to neurorehabilitation of cognitive disabilities
    • Jan.
    • P. M. Arenth, J. H. Ricker, and M. T. Schultheis, "Applications of functional nearinfrared spectroscopy (fnirs) to neurorehabilitation of cognitive disabilities, " The Clinical neuropsychologist, vol. 21, pp. 38-57, Jan 2007.
    • (2007) The Clinical Neuropsychologist , vol.21 , pp. 38-57
    • Arenth, P.M.1    Ricker, J.H.2    Schultheis, M.T.3
  • 4
    • 4344692576 scopus 로고    scopus 로고
    • On the suitability of nearinfrared (nir) systems for next-generation brain-computer interfaces
    • Aug.
    • S. Coyle, T. Ward, C. Markham, and G. McDarby, "On the suitability of nearinfrared (nir) systems for next-generation brain-computer interfaces, " Physiological Measurement, vol. 25, pp. 815-822, Aug 2004.
    • (2004) Physiological Measurement , vol.25 , pp. 815-822
    • Coyle, S.1    Ward, T.2    Markham, C.3    Mcdarby, G.4
  • 8
    • 0041958932 scopus 로고
    • Ideal spatial adaptation by wavelet shrinkage
    • D. L. Donoho and J. M. Johnstone, "Ideal spatial adaptation by wavelet shrinkage, " Biometrika, vol. 81, no. 3, pp. 425-455, 1994.
    • (1994) Biometrika , vol.81 , Issue.3 , pp. 425-455
    • Donoho, D.L.1    Johnstone, J.M.2
  • 10
    • 0032187852 scopus 로고    scopus 로고
    • Adaptive denoising based on sure risk
    • X.-P. Zhang and M. D. Desai, "Adaptive denoising based on sure risk, " Signal Processing Letters, IEEE, vol. 5, no. 10, pp. 265-267, 1998.
    • (1998) Signal Processing Letters, IEEE , vol.5 , Issue.10 , pp. 265-267
    • Zhang, X.-P.1    Desai, M.D.2
  • 11
    • 77951735956 scopus 로고    scopus 로고
    • Do radio frequencies of medical instruments common in the operating room interfere with near-infrared spectroscopy signals?
    • B. Shadgan, B. Molavi, D. Reid, G. A. Dumont, A. J. Macnab, and P. J. O'Brien, "Do radio frequencies of medical instruments common in the operating room interfere with near-infrared spectroscopy signals?, " in Proc. SPIE, 2010.
    • (2010) Proc. SPIE
    • Shadgan, B.1    Molavi, B.2    Reid, D.3    Dumont, G.A.4    Macnab, A.J.5    O'brien, P.J.6
  • 12
    • 0031289796 scopus 로고    scopus 로고
    • New and highly sensitive continuous-wave near-infrared spectrophotometer with multiple detectors
    • D. S. van, W. N. Colier, R. J. F. Houston, and B. Oeseburg, "New and highly sensitive continuous-wave near-infrared spectrophotometer with multiple detectors, " in Proc. SPIE, vol. 3194, pp. 63-72, 1998.
    • (1998) Proc. SPIE , vol.3194 , pp. 63-72
    • Van, D.S.1    Colier, W.N.2    Houston, R.J.F.3    Oeseburg, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.