메뉴 건너뛰기




Volumn 18, Issue 5, 2010, Pages 288-291

Repeat endovascular exclusion for distal tear after treatment of primary aortic dissection by endovascular exclusion

Author keywords

Aortic dissection; Endovascular exclusion; Stent graft

Indexed keywords

AGED; AORTA DISSECTION; ARTICLE; BLOOD VESSEL COMPLIANCE; CASE REPORT; COLOR ULTRASOUND FLOWMETRY; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; DIGITAL SUBTRACTION ANGIOGRAPHY; DISEASE CLASSIFICATION; DISEASE SEVERITY; ENDOLEAK; ENDOVASCULAR SURGERY; HEART EJECTION FRACTION; HUMAN; IMAGING; KIDNEY FAILURE; LUNG FUNCTION; MALE; PRIORITY JOURNAL; RECURRENT DISEASE; STENT;

EID: 77958613703     PISSN: 17085381     EISSN: None     Source Type: Journal    
DOI: 10.2310/6670.2010.00049     Document Type: Article
Times cited : (5)

References (9)
  • 1
    • 0033586990 scopus 로고    scopus 로고
    • Endovascular stent-graft placement for the treatment of acute aortic dissection
    • Dake MD, Kato N, Mitchell RS, et al. Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med 1999;340:1546-52.
    • (1999) N Engl J Med , vol.340 , pp. 1546-1552
    • Dake, M.D.1    Kato, N.2    Mitchell, R.S.3
  • 2
    • 12144281713 scopus 로고    scopus 로고
    • Elective stent-graft treatment of aortic dissections
    • Lee KH, Won JY, Lee DY, et al. Elective stent-graft treatment of aortic dissections. J Endovasc Ther 2004;11:667-75.
    • (2004) J Endovasc Ther , vol.11 , pp. 667-675
    • Lee, K.H.1    Won, J.Y.2    Lee, D.Y.3
  • 3
    • 7244243818 scopus 로고    scopus 로고
    • Expanding false lumen in the abdominal aorta 5 years after endovascular repair of a type B aortic dissection: Successful exclusion of 3 distal re-entry sites
    • DOI 10.1583/04-1266.1
    • Joung B, Ko YG, Park SH, et al. Expanding false lumen in the abdominal aorta 5 years after endovascular repair of a type B aortic dissection: successful exclusion of 3 distal re-entry sites. J Endovasc Ther 2004;11:577-81. (Pubitemid 39435087)
    • (2004) Journal of Endovascular Therapy , vol.11 , Issue.5 , pp. 577-581
    • Joung, B.1    Ko, Y.-G.2    Park, S.-H.3    Lee, D.-Y.4    Jang, Y.5    Lim, S.-H.6    Shim, W.H.7
  • 4
    • 0028631110 scopus 로고
    • Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms
    • Dake MD, Miller DC, Semba CP, et al. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med 1994;331:1729-34.
    • (1994) N Engl J Med , vol.331 , pp. 1729-1734
    • Dake, M.D.1    Miller, D.C.2    Semba, C.P.3
  • 5
    • 0035458309 scopus 로고    scopus 로고
    • Aneurysmal degeneration of the aorta after stentgraft repair of acute aortic dissection
    • Kato N, Hirano T, Kawaguchi T, et al. Aneurysmal degeneration of the aorta after stentgraft repair of acute aortic dissection. J Vasc Surg 2001;34:513-8.
    • (2001) J Vasc Surg , vol.34 , pp. 513-518
    • Kato, N.1    Hirano, T.2    Kawaguchi, T.3
  • 6
    • 1042291143 scopus 로고    scopus 로고
    • Serial CT volume and thrombus length measurements after endovascular repair of Stanford type B aortic dissection
    • Czermak BV, Mallouhi A, Perkmann R, et al. Serial CT volume and thrombus length measurements after endovascular repair of Stanford type B aortic dissection. J Endovasc Ther 2004;11:1-12.
    • (2004) J Endovasc Ther , vol.11 , pp. 1-12
    • Czermak, B.V.1    Mallouhi, A.2    Perkmann, R.3
  • 8
    • 20444435888 scopus 로고    scopus 로고
    • Endoluminal stent-graft stabilization for thoracic aortic dissection
    • Nathanson DR, Rodriguez-Lopez JA, Ramaiah VG., et al. Endoluminal stent-graft stabilization for thoracic aortic dissection. J Endovasc Ther 2005;12:354-9.
    • (2005) J Endovasc Ther , vol.12 , pp. 354-359
    • Nathanson, D.R.1    Rodriguez-Lopez, J.A.2    Ramaiah, V.G.3
  • 9
    • 20444445554 scopus 로고    scopus 로고
    • Changes in false lumen after transluminal stent-graft placement in aortic dissections. Six years experience
    • Kusagawa H, Shimono T, Ishida M, et al. Changes in false lumen after transluminal stent-graft placement in aortic dissections. Six years experience. Circulation 2005;111:2951-7.
    • (2005) Circulation , vol.111 , pp. 2951-2957
    • Kusagawa, H.1    Shimono, T.2    Ishida, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.