메뉴 건너뛰기




Volumn 55, Issue 5, 2010, Pages 291-300

Clinical proof of practicability for an ECG device without any conductive contact

Author keywords

capacitively coupled electrodes; ECG; electrocardiogram; non conductive contact; premedication department; rhythm disturbances

Indexed keywords

CAPACITIVELY COUPLED ELECTRODES; ECG; ELECTROCARDIOGRAM; NON-CONDUCTIVE CONTACT; PREMEDICATION DEPARTMENT; RHYTHM DISTURBANCES;

EID: 77958610202     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/BMT.2010.035     Document Type: Article
Times cited : (12)

References (17)
  • 1
  • 3
    • 34047094043 scopus 로고    scopus 로고
    • Contactless sensors for surface electromyography
    • New York City, New York, USA, Conf Proc IEEE Eng Med Biol Soc
    • Gourmelon L, Langereis G. Contactless sensors for surface electromyography. In: 28th IEEE EMBS Annual International Conference, New York City, New York, USA, Conf Proc IEEE Eng Med Biol Soc. 2006; 1: 2514-2517.
    • (2006) 28th IEEE EMBS Annual International Conference , vol.1 , pp. 2514-2517
    • Gourmelon, L.1    Langereis, G.2
  • 4
    • 79956006562 scopus 로고    scopus 로고
    • Remote detection of human electroencephalograms using ultrahigh input impedance electric potential sensors
    • Harland CJ, Clark TD, Prance RJ. Remote detection of human electroencephalograms using ultrahigh input impedance electric potential sensors. Appl Phys Lett 2002; 81: 3284-3286.
    • (2002) Appl Phys Lett , vol.81 , pp. 3284-3286
    • Harland, C.J.1    Clark, T.D.2    Prance, R.J.3
  • 5
    • 0027606448 scopus 로고
    • Monitoring of electrocardiograms in bed without utilizing body surface electrodes
    • Ishijima M. Monitoring of electrocardiograms in bed without utilizing body surface electrodes. IEEE Trans Biomed Eng 1993; 40: 593-594.
    • (1993) IEEE Trans Biomed Eng , vol.40 , pp. 593-594
    • Ishijima, M.1
  • 6
    • 11144324391 scopus 로고    scopus 로고
    • The ECG measurement in the bathtub using the insulated electrodes
    • San Francisco, California, USA, Conf Proc IEEE Eng Med Biol Soc
    • Kim KK, Lim YK, Park KS. The ECG measurement in the bathtub using the insulated electrodes. In: 26th IEEE EMBS Annual International Conference, San Francisco, California, USA, Conf Proc IEEE Eng Med Biol Soc. 2004; 4: 2383-2385.
    • (2004) 26th IEEE EMBS Annual International Conference , vol.4 , pp. 2383-2385
    • Kim, K.K.1    Lim, Y.K.2    Park, K.S.3
  • 7
    • 11144285010 scopus 로고    scopus 로고
    • The electrically non-contacting ECG measurement on the toilet seat using the capacitivelycoupled insulated electrodes
    • San Francisco, California, USA, Conf Proc IEEE Eng Med Biol Soc
    • Kim KK, Lim YK, Park KS. The electrically non-contacting ECG measurement on the toilet seat using the capacitivelycoupled insulated electrodes. In: 26th IEEE EMBS Annual International Conference, San Francisco, California, USA, Conf Proc IEEE Eng Med Biol Soc. 2004; 4: 2375-2378.
    • (2004) 26th IEEE EMBS Annual International Conference , vol.4 , pp. 2375-2378
    • Kim, K.K.1    Lim, Y.K.2    Park, K.S.3
  • 8
    • 33846924873 scopus 로고    scopus 로고
    • Common mode noise cancellation for electrically non-contact ECG measurement system on a chair
    • Shanghai, China, Conf Proc IEEE Eng Med Biol Soc
    • Kim KK, Lim YK, Park KS. Common mode noise cancellation for electrically non-contact ECG measurement system on a chair. In: 27th IEEE EMBS Annual International Conference, Shanghai, China, Conf Proc IEEE Eng Med Biol Soc. 2005; 6: 5881-5883.
    • (2005) 27th IEEE EMBS Annual International Conference , vol.6 , pp. 5881-5883
    • Kim, K.K.1    Lim, Y.K.2    Park, K.S.3
  • 11
    • 0014446462 scopus 로고
    • Capacitive electrocardiographic and bioelectric electrodes
    • Lopez A Jr, Richardson PC. Capacitive electrocardiographic and bioelectric electrodes. IEEE Trans Biomed Eng 1969; 16: 99.
    • (1969) IEEE Trans Biomed Eng , vol.16 , pp. 99
    • Lopez Jr., A.1    Richardson, P.C.2
  • 12
    • 77249176156 scopus 로고    scopus 로고
    • Capacitive ECG system with direct access to standard leads and body surface potential mapping
    • Oehler M, Schilling M, Esperer HD. Capacitive ECG system with direct access to standard leads and body surface potential mapping. Biomed Tech (Berl) 2009; 54: 329-335.
    • (2009) Biomed Tech (Berl) , vol.54 , pp. 329-335
    • Oehler, M.1    Schilling, M.2    Esperer, H.D.3
  • 13
    • 30244432066 scopus 로고
    • The insulated electrode: A pasteless electrocardiographic technique
    • Boston, Massachusetts, USA
    • Richardson PC. The insulated electrode: a pasteless electrocardiographic technique. In: 20th Annual Conference on Engineering in Medicine and Biology, Boston, Massachusetts, USA, 1967: 157.
    • (1967) 20th Annual Conference on Engineering in Medicine and Biology , vol.157
    • Richardson, P.C.1
  • 16
    • 57649243092 scopus 로고    scopus 로고
    • Development of a wireless capacitive sensor for ambulatory ECG monitoring over clothes
    • Yama Y, Ueno A, Uchikawa Y. Development of a wireless capacitive sensor for ambulatory ECG monitoring over clothes. Conf Proc IEEE Eng Med Biol Soc 2007: 5728-5731.
    • (2007) Conf Proc IEEE Eng Med Biol Soc , pp. 5728-5731
    • Yama, Y.1    Ueno, A.2    Uchikawa, Y.3
  • 17
    • 49349115462 scopus 로고    scopus 로고
    • Preoperative evaluation of cardiac risk patients for non-cardiac surgery. New guidelines of the ACC/AHA
    • Zwissler B. Preoperative evaluation of cardiac risk patients for non-cardiac surgery. New guidelines of the ACC/AHA 2007. Anaesthesist 2008; 57: 717-719.
    • (2007) Anaesthesist , vol.57 , pp. 717-719
    • Zwissler, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.