메뉴 건너뛰기




Volumn 195, Issue 4, 2010, Pages 1015-1020

Optimization of kVp and mAs for pediatric low-dose simulated abdominal CT: Is it best to base parameter selection on object circumference?

Author keywords

Abdominal imaging; ALARA; kVp; mAs; Pediatric radiology; Radiation dose

Indexed keywords

POLY(METHYL METHACRYLATE);

EID: 77958532002     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.09.3862     Document Type: Article
Times cited : (60)

References (26)
  • 1
    • 34247624184 scopus 로고    scopus 로고
    • American College of Radiology white paper on radiation dose in medicine
    • American College of Radiology
    • Amis ES Jr, Butler PF, Applegate KE, et al.; American College of Radiology. American College of Radiology white paper on radiation dose in medicine. J Am Coll Radiol 2007; 4:272-284
    • (2007) J Am Coll Radiol , vol.4 , pp. 272-284
    • Amis Jr., E.S.1    Butler, P.F.2    Applegate, K.E.3
  • 2
    • 39149106111 scopus 로고    scopus 로고
    • The 'Image Gently' campaign: Increasing CT radiation dose awareness through a national education and awareness program
    • Goske MJ, Applegate KE, Boylan J, et al. The 'Image Gently' campaign: increasing CT radiation dose awareness through a national education and awareness program. Pediatr Radiol 2008; 38:265-269
    • (2008) Pediatr Radiol , vol.38 , pp. 265-269
    • Goske, M.J.1    Applegate, K.E.2    Boylan, J.3
  • 3
    • 77950136923 scopus 로고    scopus 로고
    • National Council on Radiation Protection and Measurements report shows substantial medical exposure increase
    • Schauer DA, Linton OW. National Council on Radiation Protection and Measurements report shows substantial medical exposure increase. Radiology 2009; 253:293-296
    • (2009) Radiology , vol.253 , pp. 293-296
    • Schauer, D.A.1    Linton, O.W.2
  • 4
    • 0141993779 scopus 로고    scopus 로고
    • Computed tomography and radiation risks: What pediatric health care providers should know
    • Frush DP, Donnelly LF, Rosen NS. Computed tomography and radiation risks: what pediatric health care providers should know. Pediatrics 2003; 112:951-957
    • (2003) Pediatrics , vol.112 , pp. 951-957
    • Frush, D.P.1    Donnelly, L.F.2    Rosen, N.S.3
  • 6
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner D, Elliston C, Hall E, Berdon W. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR 2001; 176:289-296
    • (2001) AJR , vol.176 , pp. 289-296
    • Brenner, D.1    Elliston, C.2    Hall, E.3    Berdon, W.4
  • 7
    • 10744219719 scopus 로고    scopus 로고
    • Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
    • Brenner DJ, Doll R, Goodhead DT, et al. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci U S A 2003; 100:13,761-13,766
    • (2003) Proc Natl Acad Sci U S A , vol.100
    • Brenner, D.J.1    Doll, R.2    Goodhead, D.T.3
  • 8
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography: An increasing source of radiation exposure
    • Brenner DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med 2007; 357:2277-2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 9
    • 0034944282 scopus 로고    scopus 로고
    • Radiation exposures to patients from CT: Reality, public perception, and policy
    • Nickoloff EL, Alderson PO. Radiation exposures to patients from CT: reality, public perception, and policy. AJR 2001; 177:285-287
    • (2001) AJR , vol.177 , pp. 285-287
    • Nickoloff, E.L.1    Alderson, P.O.2
  • 10
    • 65649136577 scopus 로고    scopus 로고
    • Image Gently Vendor Summit: Working together for better estimates of pediatric radiation dose from CT
    • Strauss KJ, Goske MJ, Frush DP, Butler PF, Morrison G. Image Gently Vendor Summit: working together for better estimates of pediatric radiation dose from CT. AJR 2009; 192:1169-1175
    • (2009) AJR , vol.192 , pp. 1169-1175
    • Strauss, K.J.1    Goske, M.J.2    Frush, D.P.3    Butler, P.F.4    Morrison, G.5
  • 11
    • 0035141920 scopus 로고    scopus 로고
    • Helical CT of the body: Are settings adjusted for pediatric patients?
    • Paterson A, Frush DP, Donnelly LF. Helical CT of the body: are settings adjusted for pediatric patients? AJR 2001; 176:297-301
    • (2001) AJR , vol.176 , pp. 297-301
    • Paterson, A.1    Frush, D.P.2    Donnelly, L.F.3
  • 12
    • 0036176707 scopus 로고    scopus 로고
    • Improved pediatric multidetector body CT using a size-based color-coded format
    • Frush DP, Soden B, Frush KS, Lowry C. Improved pediatric multidetector body CT using a size-based color-coded format. AJR 2002; 178:721-726
    • (2002) AJR , vol.178 , pp. 721-726
    • Frush, D.P.1    Soden, B.2    Frush, K.S.3    Lowry, C.4
  • 13
    • 49149102462 scopus 로고    scopus 로고
    • Pediatric body MDCT: A 5-year follow-up survey of scanning parameters used by pediatric radiologists
    • Arch ME, Frush DP. Pediatric body MDCT: a 5-year follow-up survey of scanning parameters used by pediatric radiologists. AJR 2008; 191:611-617
    • (2008) AJR , vol.191 , pp. 611-617
    • Arch, M.E.1    Frush, D.P.2
  • 14
    • 33745287153 scopus 로고    scopus 로고
    • Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: A phantom and human study
    • Kalva SP, Sahani DV, Hahn PF, Saini S. Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study. J Comput Assist Tomogr 2006; 30:391-397
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 391-397
    • Kalva, S.P.1    Sahani, D.V.2    Hahn, P.F.3    Saini, S.4
  • 15
    • 33846471867 scopus 로고    scopus 로고
    • Patient radiation doses from adult and pediatric CT
    • Huda W, Vance A. Patient radiation doses from adult and pediatric CT. AJR 2007; 188:540-546
    • (2007) AJR , vol.188 , pp. 540-546
    • Huda, W.1    Vance, A.2
  • 16
    • 59649088090 scopus 로고    scopus 로고
    • Patient exposure and image quality of low-dose pulmonary computed tomography angiography: Comparison of 100- And 80-kVp protocols
    • Szucs-Farkas Z, Kurmann L, Strautz T, et al. Patient exposure and image quality of low-dose pulmonary computed tomography angiography: comparison of 100- and 80-kVp protocols. Invest Radiol 2008; 43:871-876
    • (2008) Invest Radiol , vol.43 , pp. 871-876
    • Szucs-Farkas, Z.1    Kurmann, L.2    Strautz, T.3
  • 17
    • 12544253582 scopus 로고    scopus 로고
    • Aorto-iliac multidetector-row CT angiography with low kV settings: Improved vessel enhancement and simultaneous reduction of radiation dose
    • Wintersperger B, Jakobs T, Herzog P, et al. Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 2005; 15:334-341
    • (2005) Eur Radiol , vol.15 , pp. 334-341
    • Wintersperger, B.1    Jakobs, T.2    Herzog, P.3
  • 18
    • 33750299544 scopus 로고    scopus 로고
    • Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography
    • [web]:W490-W497
    • Nakayama Y, Awai K, Funama Y, et al. Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR 2006; 187:1266; [web]:W490-W497
    • (2006) AJR , vol.187 , pp. 1266
    • Nakayama, Y.1    Awai, K.2    Funama, Y.3
  • 19
    • 15344342736 scopus 로고    scopus 로고
    • Improved vascular opacification in cerebral computed tomography angiography with 80 kVp
    • Bahner ML, Bengel A, Brix G, et al. Improved vascular opacification in cerebral computed tomography angiography with 80 kVp. Invest Radiol 2005; 40:229-234
    • (2005) Invest Radiol , vol.40 , pp. 229-234
    • Bahner, M.L.1    Bengel, A.2    Brix, G.3
  • 20
    • 43649107007 scopus 로고    scopus 로고
    • Pediatric cardiovascular CT angiography: Radiation dose reduction using automatic anatomic tube current modulation
    • Herzog C, Mulvihill DM, Nguyen SA, et al. Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. AJR 2008; 190:1232-1240
    • (2008) AJR , vol.190 , pp. 1232-1240
    • Herzog, C.1    Mulvihill, D.M.2    Nguyen, S.A.3
  • 21
    • 0035143460 scopus 로고    scopus 로고
    • Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large Children's Hospital
    • Donnelly LF, Emery KH, Brody AS, et al. Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large Children's Hospital. AJR 2001; 176:303-306
    • (2001) AJR , vol.176 , pp. 303-306
    • Donnelly, L.F.1    Emery, K.H.2    Brody, A.S.3
  • 22
    • 0033735138 scopus 로고    scopus 로고
    • Technique factors and image quality as functions of patient weight at abdominal CT
    • Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 2000; 217:430-435
    • (2000) Radiology , vol.217 , pp. 430-435
    • Huda, W.1    Scalzetti, E.M.2    Levin, G.3
  • 23
    • 43149119002 scopus 로고    scopus 로고
    • Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: A simple estimation method
    • Thomas KE, Wang B. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method. Pediatr Radiol 2008; 38:645-656
    • (2008) Pediatr Radiol , vol.38 , pp. 645-656
    • Thomas, K.E.1    Wang, B.2
  • 25
    • 1642304438 scopus 로고    scopus 로고
    • Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients
    • Cody DD, Moxley DM, Krugh KT, O'Daniel JC, Wagner LK, Eftekhari F. Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients. AJR 2004; 182:849-859
    • (2004) AJR , vol.182 , pp. 849-859
    • Cody, D.D.1    Moxley, D.M.2    Krugh, K.T.3    O'Daniel, J.C.4    Wagner, L.K.5    Eftekhari, F.6
  • 26
    • 7044228012 scopus 로고    scopus 로고
    • Radiating dose and image quality in pediatric CT: Effect of technical factors and phantom size and shape
    • Siegel MJ, Schmidt B, Bradley D, Suess C, Hildebolt C. Radiating dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology 2004; 233:515-522
    • (2004) Radiology , vol.233 , pp. 515-522
    • Siegel, M.J.1    Schmidt, B.2    Bradley, D.3    Suess, C.4    Hildebolt, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.