메뉴 건너뛰기




Volumn 14, Issue 8, 2010, Pages 45-51

Evaluation and analysis of transient current of a DFIG wind generation system under grid fault

Author keywords

Doubly fed induction generator; Grid fault; Low voltage ride through; Transient current evaluation; Wind power

Indexed keywords

ACTIVE POWER; DOUBLY FED INDUCTION GENERATORS; DOUBLY-FED INDUCTION GENERATOR; DRIVE TRAIN; EVALUATION AND ANALYSIS; GRID FAULT; GRID VOLTAGE; INITIAL CONDITIONS; LOW-VOLTAGE RIDE-THROUGH; MAXIMUM VALUES; OPERATIONAL CAPABILITIES; OPERATIONAL CONDITIONS; ROTOR FLUXES; SHORT-CIRCUIT FAULT; TIME-DOMAIN SIMULATIONS; TRANSIENT CURRENT; TRANSIENT CURRENT EVALUATION; TRANSIENT MODEL; TRANSIENT PERFORMANCE; WIND GENERATION SYSTEM;

EID: 77958106421     PISSN: 1007449X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (23)

References (16)
  • 1
    • 25144466008 scopus 로고    scopus 로고
    • Transient stability of DFIG wind turbines at an external short-circuit fault
    • Sun Tao, Chen Z, Blaabjerg F. Transient stability of DFIG wind turbines at an external short-circuit fault [J]. Wind Energy, 2005, 8(3): 345-360.
    • (2005) Wind Energy , vol.8 , Issue.3 , pp. 345-360
    • Sun, T.1    Chen, Z.2    Blaabjerg, F.3
  • 2
    • 34948858020 scopus 로고    scopus 로고
    • Study on transient voltage stability enhancement of grid-connected wind farm with doubly fed induction generator installations
    • Chi Yongning, Wang Weisheng, Dai Huizhu. Study on transient voltage stability enhancement of grid-connected wind farm with doubly fed induction generator installations [J]. Proceedings of the CSEE, 2007, 27(25): 25-31.
    • (2007) Proceedings of the CSEE , vol.27 , Issue.25 , pp. 25-31
    • Chi, Y.1    Wang, W.2    Dai, H.3
  • 3
    • 56349118539 scopus 로고    scopus 로고
    • Electro-magnetic transition of double fed wind turbines initiated by voltage dip
    • Yang Shuying, Zhang Xing, Zhang Congwei, et al. Electro-magnetic transition of double fed wind turbines initiated by voltage dip [J]. Automation of Electric Power Systems, 2008, 32(19): 85-91.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.19 , pp. 85-91
    • Yang, S.1    Zhang, X.2    Zhang, C.3
  • 4
    • 77958087641 scopus 로고    scopus 로고
    • Chinese source
    • 2009: 19-39.
    • (2009) , pp. 19-39
  • 5
    • 54549127229 scopus 로고    scopus 로고
    • Analysis of three-phase short circuit current of doubly fed induction generator
    • Zhang Xueguang, Xu Dianguo, Li Weiwei. Analysis of three-phase short circuit current of doubly fed induction generator [J]. Electric Machines and Control, 2008, 12(5): 493-497.
    • (2008) Electric Machines and Control , vol.12 , Issue.5 , pp. 493-497
    • Zhang, X.1    Xu, D.2    Li, W.3
  • 6
    • 46449100341 scopus 로고    scopus 로고
    • Effect of equivalent models of wind turbines on analysis results of transient stability for wind generator systems
    • Li Hui, Han Li, Zhao Bin, et al. Effect of equivalent models of wind turbines on analysis results of transient stability for wind generator systems [J]. Proceedings of the CSEE, 2008, 28(17): 105-111.
    • (2008) Proceedings of the CSEE , vol.28 , Issue.17 , pp. 105-111
    • Li, H.1    Han, L.2    Zhao, B.3
  • 7
    • 33947634098 scopus 로고    scopus 로고
    • Short circuit current of wind turbines with doubly fed induction generator
    • Morren J, De Haan S W H. Short circuit current of wind turbines with doubly fed induction generator [J]. IEEE Trans on Energy Conversion, 2007, 22(1): 174-180.
    • (2007) IEEE Trans on Energy Conversion , vol.22 , Issue.1 , pp. 174-180
    • Morren, J.1    de Haan, S.W.H.2
  • 8
    • 36349031105 scopus 로고    scopus 로고
    • Ride through control strategy of AC excited wind power generator for grid short-circuit fault
    • Yao Jun, Liao Yong, Tang Jianping. Ride through control strategy of AC excited wind power generator for grid short-circuit fault [J]. Proceedings of the CSEE, 2007, 27(30): 64-71.
    • (2007) Proceedings of the CSEE , vol.27 , Issue.30 , pp. 64-71
    • Yao, J.1    Liao, Y.2    Tang, J.3
  • 9
    • 77958098072 scopus 로고    scopus 로고
    • Chinese source
    • 2006.
    • (2006)
  • 10
    • 0036872939 scopus 로고    scopus 로고
    • Modeling of wind turbines for power system studies
    • Petru T, Thiringer T. Modeling of wind turbines for power system studies [J]. IEEE Transaction on Power System, 2002, 17(4): 1132-1139.
    • (2002) IEEE Transaction on Power System , vol.17 , Issue.4 , pp. 1132-1139
    • Petru, T.1    Thiringer, T.2
  • 11
    • 34548019038 scopus 로고    scopus 로고
    • Modeling of wind turbines based on doubly fed induction generators for power system stability studies
    • Erlich I, Kretschmann J, Fortmann J, et al. Modeling of wind turbines based on doubly fed induction generators for power system stability studies [J]. IEEE Trans on Power Systems, 2007, 22(3): 909-919.
    • (2007) IEEE Trans on Power Systems , vol.22 , Issue.3 , pp. 909-919
    • Erlich, I.1    Kretschmann, J.2    Fortmann, J.3
  • 12
    • 37749007513 scopus 로고    scopus 로고
    • Analysis on the low voltage ride through technology of DFIG
    • Wang Wei, Sun Mingdong, Zhu Xiaodong. Analysis on the low voltage ride through technology of DFIG [J]. Automation of Electric Power Systems, 2007, 31(23): 84-89.
    • (2007) Automation of Electric Power Systems , vol.31 , Issue.23 , pp. 84-89
    • Wang, W.1    Sun, M.2    Zhu, X.3
  • 13
    • 0026120682 scopus 로고
    • Transient state analysis of a doubly-fed induction generator under three phase short circuit
    • Vicatos M S, Tegopoulos J A. Transient state analysis of a doubly-fed induction generator under three phase short circuit [J]. IEEE Trans. Energy Convers, 1991, 6(1): 62-68.
    • (1991) IEEE Trans. Energy Convers , vol.6 , Issue.1 , pp. 62-68
    • Vicatos, M.S.1    Tegopoulos, J.A.2
  • 14
    • 77950990802 scopus 로고    scopus 로고
    • Analysis and calculation of short circuit current of doubly fed induction generator
    • Chicago: IEEE
    • Li D D. Analysis and calculation of short circuit current of doubly fed induction generator [C]// IEEE PES Transmission and Distribution Conference and Exposition. Chicago: IEEE, 2008: 210-214.
    • (2008) IEEE PES Transmission and Distribution Conference and Exposition , pp. 210-214
    • Li, D.D.1
  • 15
    • 67649450314 scopus 로고    scopus 로고
    • Analysis of the by-pass resistance of an active crowbar for doubly-fed induction generator based wind turbines under grid faults
    • Wuhang, China: ICEMS
    • Zhang Wei, Zhou Peng, He Yikang. Analysis of the by-pass resistance of an active crowbar for doubly-fed induction generator based wind turbines under grid faults [C]// Proc. of Int. Conf. on Electrical Machines and Systems. Wuhang, China: ICEMS, 2008: 2316-2321.
    • (2008) Proc. of Int. Conf. on Electrical Machines and Systems , pp. 2316-2321
    • Zhang, W.1    Zhou, P.2    He, Y.3
  • 16
    • 0038449472 scopus 로고    scopus 로고
    • Analysis, Modeling and control of doubly-fed induction generators for wind turbines
    • Sweden: Chalmers University of Technology
    • Petersson A. Analysis, Modeling and control of doubly-fed induction generators for wind turbines [D]. Sweden: Chalmers University of Technology, 2005.
    • (2005)
    • Petersson, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.