메뉴 건너뛰기




Volumn 38, Issue 5, 2010, Pages 536-537

Biometry formula choice and cataract refractive outcomes

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMY; BIOMETRY; CALCULATION; CATARACT; EYE REFRACTION; LENS IMPLANT; LETTER; MYOPIA; OUTCOME ASSESSMENT; CATARACT EXTRACTION; HUMAN; LENS IMPLANTATION; POSTOPERATIVE COMPLICATIONS; PROCEDURES; REFRACTIVE ERRORS; STANDARDS; TREATMENT OUTCOME;

EID: 77958093773     PISSN: 14426404     EISSN: 14429071     Source Type: Journal    
DOI: 10.1111/j.1442-9071.2010.2340_1.x     Document Type: Letter
Times cited : (2)

References (12)
  • 1
    • 74949128293 scopus 로고    scopus 로고
    • Intraocular lens power calculations: are we stuck in the past?
    • Hill WE. Intraocular lens power calculations: are we stuck in the past? Clin Experiment Ophthalmol 2009; 37: 761-2.
    • (2009) Clin Experiment Ophthalmol , vol.37 , pp. 761-762
    • Hill, W.E.1
  • 3
    • 68349133399 scopus 로고    scopus 로고
    • Comparison of refractive out-comes using immersion ultrasound biometry and IOL-Master biometry
    • Landers J, Goggin M. Comparison of refractive out-comes using immersion ultrasound biometry and IOL-Master biometry. Clin Experiment Ophthalmol 2009; 37: 566-9.
    • (2009) Clin Experiment Ophthalmol , vol.37 , pp. 566-569
    • Landers, J.1    Goggin, M.2
  • 4
    • 66849114919 scopus 로고    scopus 로고
    • Comparing ultrasound biometry with partial coherence interfer-ometry for intraocular lens power calculations: a randomized study
    • Raymond S, Favilla I, Santamaria L. Comparing ultrasound biometry with partial coherence interfer-ometry for intraocular lens power calculations: a randomized study. Invest Ophthalmol Vis Sci 2009; 50: 2547-52.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 2547-2552
    • Raymond, S.1    Favilla, I.2    Santamaria, L.3
  • 5
    • 58249121691 scopus 로고    scopus 로고
    • Benchmark standards for refractive outcomes after NHS cataract surgery
    • Gale RP, Saldana M, Johnston RL, Zuberbuhler B, McKibbin M. Benchmark standards for refractive outcomes after NHS cataract surgery. Eye 2009; 23: 149-52.
    • (2009) Eye , vol.23 , pp. 149-152
    • Gale, R.P.1    Saldana, M.2    Johnston, R.L.3    Zuberbuhler, B.4    McKibbin, M.5
  • 6
    • 33751427623 scopus 로고    scopus 로고
    • Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and SRK/T formulas
    • Narvaez J, Zimmerman G, Stulting RD, Chang DH. Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and SRK/T formulas. J Cataract Refract Surg 2006; 32: 2050-3.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 2050-2053
    • Narvaez, J.1    Zimmerman, G.2    Stulting, R.D.3    Chang, D.H.4
  • 7
    • 0033801149 scopus 로고    scopus 로고
    • Clinical results using the Holladay 2 intraocular lens power formula
    • Hoffer KJ. Clinical results using the Holladay 2 intraocular lens power formula. J Cataract Refract Surg 2000; 26: 1233-7.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1233-1237
    • Hoffer, K.J.1
  • 9
    • 38649099691 scopus 로고    scopus 로고
    • Intraocular lens power calculation using the IOLMaster and various formulas in eyes with long axial length
    • Wang JK, Hu CY, Chang SW. Intraocular lens power calculation using the IOLMaster and various formulas in eyes with long axial length. J Cataract Refract Surg 2008; 34: 262-7.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 262-267
    • Wang, J.K.1    Hu, C.Y.2    Chang, S.W.3
  • 10
    • 67649774523 scopus 로고    scopus 로고
    • Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia
    • Terzi E, Wang L, Kohnen T. Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia. J Cataract Refract Surg 2009; 35: 1181-9.
    • (2009) J Cataract Refract Surg , vol.35 , pp. 1181-1189
    • Terzi, E.1    Wang, L.2    Kohnen, T.3
  • 11
    • 33646054203 scopus 로고    scopus 로고
    • Prediction of the effective postoperative (intraocular lens) anterior chamber depth
    • Olsen T. Prediction of the effective postoperative (intraocular lens) anterior chamber depth. J Cataract Refract Surg 2006; 32: 419-24.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 419-424
    • Olsen, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.