메뉴 건너뛰기




Volumn 81, Issue 1, 2011, Pages 149-157

Performance of a grid-connected wind generation system with a robust susceptance controller

Author keywords

Induction generator; Robust control; Susceptance control; Wind turbine system

Indexed keywords

ABNORMAL CONDITIONS; CONNECTION REQUIREMENTS; CONTROL STRATEGIES; EXCITATION CONTROLS; FAULT RIDE THROUGH CAPABILITY; FEEDBACK CONTROLLER; FIXED CAPACITORS; FIXED PARAMETERS; FREQUENCY DOMAINS; GENERATOR TERMINALS; GRID-CONNECTED; INDUCTION GENERATOR; LOAD CHANGE; LOW VOLTAGES; MULTIPLICATIVE UNCERTAINTY; NORMAL OPERATIONS; PID CONTROLLERS; REACTIVE POWER REQUIREMENT; ROBUST CONTROLLER DESIGN; ROBUST CONTROLLERS; SIMULATION RESULT; SUSCEPTANCE CONTROL; TERMINAL VOLTAGES; TRANSIENT DISTURBANCES; TRANSMISSION SYSTEM OPERATORS; VARIABLE SPEED; WIND GENERATION SYSTEM; WIND GUST; WIND TURBINE SYSTEM; WOUND ROTOR INDUCTION GENERATORS;

EID: 77958023926     PISSN: 03787796     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.epsr.2010.08.002     Document Type: Article
Times cited : (11)

References (20)
  • 1
    • 0037291008 scopus 로고    scopus 로고
    • General model for representing variable speed wind turbines in power system dynamic simulations
    • J.G. Slootweg, S.W.H. Hann, H. Polinder, and W.L. Kling General model for representing variable speed wind turbines in power system dynamic simulations IEEE Trans. Power Syst. 18 2003 144 151
    • (2003) IEEE Trans. Power Syst. , vol.18 , pp. 144-151
    • Slootweg, J.G.1    Hann, S.W.H.2    Polinder, H.3    Kling, W.L.4
  • 2
    • 0034156452 scopus 로고    scopus 로고
    • Control design and dynamic performance analysis of a wind turbine-induction generator unit
    • E.S. Abdin, and W. Xu Control design and dynamic performance analysis of a wind turbine-induction generator unit IEEE Trans. Energy Convers. 15 2000 91 96
    • (2000) IEEE Trans. Energy Convers. , vol.15 , pp. 91-96
    • Abdin, E.S.1    Xu, W.2
  • 5
    • 0037291008 scopus 로고    scopus 로고
    • General model for representing variable speed wind turbines in power system dynamics simulations
    • J.G. Slootweg, S.W.H. Haan, H. Polinder, and W.L. Kling General model for representing variable speed wind turbines in power system dynamics simulations IEEE Trans. Power Syst. 18 2003 144 151
    • (2003) IEEE Trans. Power Syst. , vol.18 , pp. 144-151
    • Slootweg, J.G.1    Haan, S.W.H.2    Polinder, H.3    Kling, W.L.4
  • 6
    • 34548072222 scopus 로고    scopus 로고
    • Fault ride-through of large wind farms using dynamic breaking resistors
    • A. Causebrook, D.J. Atkinson, and A.G. Jack Fault ride-through of large wind farms using dynamic breaking resistors IEEE Trans. Power Syst. 22 2007 966 975
    • (2007) IEEE Trans. Power Syst. , vol.22 , pp. 966-975
    • Causebrook, A.1    Atkinson, D.J.2    Jack, A.G.3
  • 7
    • 0037230835 scopus 로고    scopus 로고
    • Terminal voltage control of a wind turbine driven isolated induction generator using stator oriented field control
    • Florida, USA
    • D. Seyoum, M.F. Rahman, and C. Grantham Terminal voltage control of a wind turbine driven isolated induction generator using stator oriented field control Proc. IEEE-2003 Applied Power Electronics Conf and Exposition Florida, USA 2003 846 852
    • (2003) Proc. IEEE-2003 Applied Power Electronics Conf and Exposition , pp. 846-852
    • Seyoum, D.1    Rahman, M.F.2    Grantham, C.3
  • 11
    • 0030733731 scopus 로고    scopus 로고
    • Fuzzy logic based intelligent control of a variable speed cage machine wind generation system
    • M.G. Simoes, B.K. Bose, and R.J. Spiegel Fuzzy logic based intelligent control of a variable speed cage machine wind generation system IEEE Trans. Power Electr. 12 1997 87 95
    • (1997) IEEE Trans. Power Electr. , vol.12 , pp. 87-95
    • Simoes, M.G.1    Bose, B.K.2    Spiegel, R.J.3
  • 12
    • 0029773452 scopus 로고    scopus 로고
    • A rule-based fuzzy logic controller for a PWM inverter in a stand alone wind energy conversion scheme
    • R.M. Hilloowala, and A.M. Sharaf A rule-based fuzzy logic controller for a PWM inverter in a stand alone wind energy conversion scheme IEEE Trans. Ind. Appl. 32 1996 57 65
    • (1996) IEEE Trans. Ind. Appl. , vol.32 , pp. 57-65
    • Hilloowala, R.M.1    Sharaf, A.M.2
  • 14
    • 0036747177 scopus 로고    scopus 로고
    • Variable-speed wind power generation using doubly fed wound rotor induction machine - Comparison with alternative schemes
    • R. Datta, and V.T. Ranganathan Variable-speed wind power generation using doubly fed wound rotor induction machine - comparison with alternative schemes IEEE Trans. Energy Convers. 17 2002 414 421
    • (2002) IEEE Trans. Energy Convers. , vol.17 , pp. 414-421
    • Datta, R.1    Ranganathan, V.T.2
  • 16
    • 0142228356 scopus 로고    scopus 로고
    • Robust STATCOM voltage controller design using loop-shaping technique
    • A.H.M.A. Rahim, and M.F. Kandlawala Robust STATCOM voltage controller design using loop-shaping technique Electr. Power Syst. Res. 68 2004 61 74
    • (2004) Electr. Power Syst. Res. , vol.68 , pp. 61-74
    • Rahim, A.H.M.A.1    Kandlawala, M.F.2
  • 20
    • 70349579256 scopus 로고    scopus 로고
    • A review of grid code technical requirements for wind farms
    • M. Tsili, and S. Papathanassiou A review of grid code technical requirements for wind farms IET Renew. Power Gen. 3 2009 308 332
    • (2009) IET Renew. Power Gen. , vol.3 , pp. 308-332
    • Tsili, M.1    Papathanassiou, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.