메뉴 건너뛰기




Volumn 17, Issue 5, 2010, Pages 1470-1478

The ramp test - Its origins, development and application

Author keywords

high direct voltage; ramp test; Rotating machine insulation

Indexed keywords

DIRECT VOLTAGES; GROUNDWALL INSULATION; RAMP FUNCTION; RAMP TESTS; ROTATING MACHINE; ROTATING MACHINE INSULATION; STATOR WINDING; VOLTAGE SUPPLY; VOLTAGE TESTS;

EID: 77957941422     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2010.5595548     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 0007825920 scopus 로고
    • Diagnoses of ac generator insulation condition by non-destructive tests
    • A. W. W. Cameron, "Diagnoses of ac generator insulation condition by non-destructive tests", AIEE Trans. Power A pp. Syst., Vol. 71, pp. 263-269, 1952.
    • (1952) AIEE Trans. Power A pp. Syst. , vol.71 , pp. 263-269
    • Cameron, A.W.W.1
  • 2
    • 0007725422 scopus 로고
    • Testing electrical insulation of rotating machinery with high voltage direct current
    • G. L. Hill, "Testing electrical insulation of rotating machinery with high voltage direct current", AIEE Trans. Power A pp. Syst., Vol. 72, pp. 159-170, 1953.
    • (1953) AIEE Trans. Power A pp. Syst. , vol.72 , pp. 159-170
    • Hill, G.L.1
  • 3
    • 0007824701 scopus 로고
    • Corrections for dielectric absorption in high voltage dc insulation tests
    • F. R. Schleif, "Corrections for dielectric absorption in high voltage dc insulation tests", AIEE Trans. Power A pp. Syst., Vol. 75, pp. 513-517, 1956.
    • (1956) AIEE Trans. Power A pp. Syst. , vol.75 , pp. 513-517
    • Schleif, F.R.1
  • 4
    • 0007776858 scopus 로고
    • DC testing experience on rotating machine insulation
    • J. S. Johnson and A. W. Zwiener, "DC testing experience on rotating machine insulation", AIEE Trans. Power A pp. Syst., Vol. 76, pp. 416-420, 1957.
    • (1957) AIEE Trans. Power A pp. Syst. , vol.76 , pp. 416-420
    • Johnson, J.S.1    Zwiener, A.W.2
  • 5
    • 0000010889 scopus 로고
    • Generator insulation testing by continuous time-function application of direct voltage
    • B. L. McHenry, "Generator insulation testing by continuous time-function application of direct voltage", IEEE Trans. Power A pp. Syst., Vol. 86, pp. 1329-1333, 1967.
    • (1967) IEEE Trans. Power A pp. Syst. , vol.86 , pp. 1329-1333
    • McHenry, B.L.1
  • 8
    • 0033706915 scopus 로고    scopus 로고
    • Evaluation of delaminated high-voltage rotating machine stator winding groundwall insulation
    • L. Rux and S. Grzybowski, "Evaluation of delaminated high-voltage rotating machine stator winding groundwall insulation", IEEE Intern. Sympos. Electr. Insul., pp. 520-523, 2000.
    • (2000) IEEE Intern. Sympos. Electr. Insul. , pp. 520-523
    • Rux, L.1    Grzybowski, S.2
  • 12
    • 0035518215 scopus 로고    scopus 로고
    • Assessing the condition of hydrogenerator stator winding insulation using the ramped high direct-voltage test method
    • DOI 10.1109/57.969943
    • L. Rux and W. McDermid, "Assessing the condition of hydrogenerator stator winding insulation using the ramped high direct-voltage test method", IEEE Electr. Insul. Mag., Vol. 17, No. 6, pp. 27-33, 2001. (Pubitemid 34051166)
    • (2001) IEEE Electrical Insulation Magazine , vol.17 , Issue.6 , pp. 27-33
    • Rux, L.1    McDermid, W.2
  • 19
    • 70449644692 scopus 로고    scopus 로고
    • Comparison of DC ramp and DC step test results on hydro generator stators
    • L. Lamarre, E. David and A. Nair, "Comparison of DC ramp and DC step test results on hydro generator stators, IEEE Electr. Insul. Conf., pp. 468-472, 2009.
    • (2009) IEEE Electr. Insul. Conf. , pp. 468-472
    • Lamarre, L.1    David, E.2    Nair, A.3