메뉴 건너뛰기




Volumn 207, Issue 1, 2010, Pages 134-139

Design and construction of an actively frequency-switchable RF coil for field-dependent Magnetisation Transfer Contrast MRI with fast field-cycling

Author keywords

Field cycling; Magnetisation transfer; Multi tunable coil; PIN diode switch

Indexed keywords

DESIGN AND CONSTRUCTION; EXTERNAL MAGNETIC FIELD; FIELD-CYCLING; GENERATING MECHANISM; IMPEDANCE MATCHINGS; IRRADIATION PULSE; MAGNETISATION; MULTI-TUNABLE COIL; OFF-RESONANCE; PIN DIODE; PIN DIODE SWITCHES; PRE-SATURATION; Q-FACTORS; RESONANCE FREQUENCIES; RF COIL; SWITCHABLE;

EID: 77957939727     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2010.08.018     Document Type: Article
Times cited : (15)

References (20)
  • 1
    • 0024573913 scopus 로고
    • Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
    • S.D. Wolff, and R.S. Balaban Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo Magn. Reson. Med. 10 1 1989 135 144
    • (1989) Magn. Reson. Med. , vol.10 , Issue.1 , pp. 135-144
    • Wolff, S.D.1    Balaban, R.S.2
  • 3
    • 0028540605 scopus 로고
    • Field dispersion in water-macromolecular proton magnetization transfer
    • T.L. Ceckler, and R.S. Balaban Field dispersion in water-macromolecular proton magnetization transfer J. Magn. Reson. Ser B. 105 1994 242 248
    • (1994) J. Magn. Reson. ser B. , vol.105 , pp. 242-248
    • Ceckler, T.L.1    Balaban, R.S.2
  • 4
    • 37549039071 scopus 로고    scopus 로고
    • Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 Tesla
    • P. Martirosian, A. Boss, M. Deimling, B. Kiefer, C. Schraml, N.F. Schwenzer, C.D. Claussen, F. Schick, Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 Tesla. Invest. Radiol. 43 (1) (2008) 16-26.
    • (2008) Invest. Radiol. , vol.43 , Issue.1 , pp. 16-26
    • Martirosian, P.1    Boss, A.2    Deimling, M.3    Kiefer, B.4    Schraml, C.5    Schwenzer, N.F.6    Claussen, C.D.7    Schick, F.8
  • 5
    • 0031813421 scopus 로고    scopus 로고
    • Design, construction and use of a large-sample field-cycled PEDRI imager
    • D.J. Lurie, M.A. Foster, D. Yeung, and J.M.S. Hutchison Design, construction and use of a large-sample field-cycled PEDRI imager Phys. Med. Biol. 43 7 1998 1877 1886
    • (1998) Phys. Med. Biol. , vol.43 , Issue.7 , pp. 1877-1886
    • Lurie, D.J.1    Foster, M.A.2    Yeung, D.3    Hutchison, J.M.S.4
  • 7
    • 66249091924 scopus 로고    scopus 로고
    • Delta relaxation enhanced mr: Improving activation - Specificity of molecular probes through R1 dispersion imaging
    • J.K. Alford, B.K. Rutt, T.J. Scholl, W.B. Handler, and B.A. Chronik Delta relaxation enhanced mr: improving activation - Specificity of molecular probes through R1 dispersion imaging Magn. Reson. Med. 61 4 2009 796 802
    • (2009) Magn. Reson. Med. , vol.61 , Issue.4 , pp. 796-802
    • Alford, J.K.1    Rutt, B.K.2    Scholl, T.J.3    Handler, W.B.4    Chronik, B.A.5
  • 8
    • 77950188024 scopus 로고    scopus 로고
    • Off-resonance magnetisation transfer contrast MRI using fast field-cycling technique
    • Honolulu, USA
    • C.-H. Choi, G.R. Davies, D.J. Lurie, Off-resonance magnetisation transfer contrast MRI using fast field-cycling technique, in: Proceedings of the 17th Annual Meeting of ISMRM, Honolulu, USA, 2009, p. 2747.
    • (2009) Proceedings of the 17th Annual Meeting of ISMRM , pp. 2747
    • Choi, C.-H.1    Davies, G.R.2    Lurie, D.J.3
  • 9
    • 77950189184 scopus 로고    scopus 로고
    • Off-resonance magnetisation transfer contrast (MTC) MRI using fast field-cycling (FFC)
    • C.-H. Choi, G.R. Davies, and D.J. Lurie Off-resonance magnetisation transfer contrast (MTC) MRI using fast field-cycling (FFC) J. Magn. Reson. 204 1 2010 145 149
    • (2010) J. Magn. Reson. , vol.204 , Issue.1 , pp. 145-149
    • Choi, C.-H.1    Davies, G.R.2    Lurie, D.J.3
  • 12
    • 38249017194 scopus 로고
    • A design for a double-tuned birdcage coil for use in an integrated MRI/MRS examination
    • G. Isaac, M.D. Schnall, R.E. Lenkinski, and K. Vogele A design for a double-tuned birdcage coil for use in an integrated MRI/MRS examination J. Magn. Reson. 89 1990 41 45
    • (1990) J. Magn. Reson. , vol.89 , pp. 41-45
    • Isaac, G.1    Schnall, M.D.2    Lenkinski, R.E.3    Vogele, K.4
  • 13
    • 0030671545 scopus 로고    scopus 로고
    • Dual-frequency, dual-quadrature, birdcage RF coil design with identical B1 pattern for sodium and proton imaging of the human brain at 1.5 T
    • G.X. Shen, F.E. Boada, and K.R. Thulborn Dual-frequency, dual-quadrature, birdcage RF coil design with identical B1 pattern for sodium and proton imaging of the human brain at 1.5 T Magn. Reson. Med. 38 1997 717 725
    • (1997) Magn. Reson. Med. , vol.38 , pp. 717-725
    • Shen, G.X.1    Boada, F.E.2    Thulborn, K.R.3
  • 14
    • 0031885959 scopus 로고    scopus 로고
    • Automatic probe tuning and matching
    • F. Hwang, and D.I. Hoult Automatic probe tuning and matching Magn. Reson. Med. 39 1998 214 222
    • (1998) Magn. Reson. Med. , vol.39 , pp. 214-222
    • Hwang, F.1    Hoult, D.I.2
  • 15
    • 0036298938 scopus 로고    scopus 로고
    • Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3 T
    • L. Tugan Muftuler, G. Gulsen, K.D. Sezen, and O. Nalcioglu Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3 T J. Magn. Reson. 155 2002 39 44
    • (2002) J. Magn. Reson. , vol.155 , pp. 39-44
    • Tugan Muftuler, L.1    Gulsen, G.2    Sezen, K.D.3    Nalcioglu, O.4
  • 17
    • 0033628737 scopus 로고    scopus 로고
    • Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy
    • H. Hirata, T. Walczak, and H.M. Swartz Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy J. Magn. Reson. 142 2000 159 167
    • (2000) J. Magn. Reson. , vol.142 , pp. 159-167
    • Hirata, H.1    Walczak, T.2    Swartz, H.M.3
  • 18
    • 55049135307 scopus 로고    scopus 로고
    • Actively decoupled transmit-receive coil-pair for mouse brain MRI Concepts
    • J.R. Garbow, C. Mcintosh, M.S. Conradi, Actively decoupled transmit-receive coil-pair for mouse brain MRI Concepts, Magn. Reson. B, 33 (4) (2008) 252-259.
    • (2008) Magn. Reson. B , vol.33 , Issue.4 , pp. 252-259
    • Garbow, J.R.1    McIntosh, C.2    Conradi, M.S.3
  • 19
    • 0033959514 scopus 로고    scopus 로고
    • A transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications
    • E.A. Barberi, J.S. Gati, B.K. Rutt, and R.S. Menon A transmit-only/ receive-only (TORO) RF system for high-field MRI/MRS applications Magn. Reson. Med. 43 2000 284 289
    • (2000) Magn. Reson. Med. , vol.43 , pp. 284-289
    • Barberi, E.A.1    Gati, J.S.2    Rutt, B.K.3    Menon, R.S.4
  • 20
    • 77957956386 scopus 로고    scopus 로고
    • Design and construction of an actively frequency-switchable RF coil for magnetisation transfer contrast MRI using fast field-cycling
    • Stockholm, Sweden
    • C.-H. Choi, I. Lavdas, J.M.S. Hutchison, D.J. Lurie, Design and construction of an actively frequency-switchable RF coil for magnetisation transfer contrast MRI using fast field-cycling, in: Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010, p. 3923.
    • (2010) Proceedings of the 18th Annual Meeting of ISMRM , pp. 3923
    • Choi, C.-H.1    Lavdas, I.2    Hutchison, J.M.S.3    Lurie, D.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.