1
-
-
33846798042
-
Diagnosis of intrathoracic lesions: Are sequential fine-needle aspiration (FNA) and core needle biopsy (CNB) combined better than either investigation alone?
-
Aviram G., Greif J., and Man A. Diagnosis of intrathoracic lesions: are sequential fine-needle aspiration (FNA) and core needle biopsy (CNB) combined better than either investigation alone? Clin Radiol 62 2007 221 226
-
(2007)
Clin Radiol
, vol.62
, pp. 221-226
-
-
Aviram, G.1
Greif, J.2
Man, A.3
-
2
-
-
33644650726
-
Transthoracic fine-needle aspiration vs concurrent core needle biopsy in diagnosis of intrathoracic lesions: A retrospective comparison of diagnostic accuracy
-
Gong Y., Sneige N., and Guo M. Transthoracic fine-needle aspiration vs concurrent core needle biopsy in diagnosis of intrathoracic lesions: a retrospective comparison of diagnostic accuracy Am J Clin Pathol 125 2006 438 444
-
(2006)
Am J Clin Pathol
, vol.125
, pp. 438-444
-
-
Gong, Y.1
Sneige, N.2
Guo, M.3
-
3
-
-
0031749803
-
Additional information from percutaneous cutting needle biopsy following fine-needle aspiration in the diagnosis of chest lesions
-
Staroselsky A.N., Schwarz Y., and Man A. Additional information from percutaneous cutting needle biopsy following fine-needle aspiration in the diagnosis of chest lesions Chest 113 1998 1522 1525 (Pubitemid 28307154)
-
(1998)
Chest
, vol.113
, Issue.6
, pp. 1522-1525
-
-
Staroselsky, A.N.1
Schwarz, Y.2
Man, A.3
Marmur, S.4
Greif, J.5
-
4
-
-
0030051348
-
Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients
-
Klein J.S., Salomon G., and Stewart E.A. Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients Radiology 198 1996 715 720
-
(1996)
Radiology
, vol.198
, pp. 715-720
-
-
Klein, J.S.1
Salomon, G.2
Stewart, E.A.3
-
5
-
-
0034523283
-
CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: Results with an automated 20-gauge coaxial cutting needle
-
Laurent F., Latrabe V., and Vergier B. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle Clin Radiol 55 2000 281 287
-
(2000)
Clin Radiol
, vol.55
, pp. 281-287
-
-
Laurent, F.1
Latrabe, V.2
Vergier, B.3
-
7
-
-
46849107727
-
Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: Which factors affect diagnostic yield and complication rates?
-
Heyer C.M., Reichelt S., and Peters S.A. Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: which factors affect diagnostic yield and complication rates? Acad Radiol 15 2008 1017 1026
-
(2008)
Acad Radiol
, vol.15
, pp. 1017-1026
-
-
Heyer, C.M.1
Reichelt, S.2
Peters, S.A.3
-
8
-
-
0031866908
-
Intrapulmonary lesions: Percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle
-
Lucidarme O., Howarth N., and Finet J.F. Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle Radiology 207 1998 759 765
-
(1998)
Radiology
, vol.207
, pp. 759-765
-
-
Lucidarme, O.1
Howarth, N.2
Finet, J.F.3
-
9
-
-
0034522999
-
CT-guided cutting needle biopsy of lung lesions-safety and efficacy of an out-patient service
-
Charig M.J., and Phillips A.J. CT-guided cutting needle biopsy of lung lesions-safety and efficacy of an out-patient service Clin Radiol 55 2000 964 969
-
(2000)
Clin Radiol
, vol.55
, pp. 964-969
-
-
Charig, M.J.1
Phillips, A.J.2
-
10
-
-
0038476397
-
Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: Retrospective analysis of 631 procedures
-
Yeow K.M., Tsay P.K., and Cheung Y.C. Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures J Vasc Interv Radiol 14 2003 581 588
-
(2003)
J Vasc Interv Radiol
, vol.14
, pp. 581-588
-
-
Yeow, K.M.1
Tsay, P.K.2
Cheung, Y.C.3
-
11
-
-
77957960113
-
Percutaneous CT-guided biopsy of the lung: Comparison between aspiration and automated cutting needles using a coaxial technique
-
Laurent F., Latrabe V., and Vergier B. Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique Cardiovasc Intervent Radiol 14 2000 1234 1240
-
(2000)
Cardiovasc Intervent Radiol
, vol.14
, pp. 1234-1240
-
-
Laurent, F.1
Latrabe, V.2
Vergier, B.3
-
12
-
-
22644448256
-
CT-guided transthoracic needle biopsy: A comparison between automated biopsy gun and fine needle aspiration
-
Arakawa H., Nakajima Y., and Kurihara Y. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration Clin Radiol 51 1996 503 506
-
(1996)
Clin Radiol
, vol.51
, pp. 503-506
-
-
Arakawa, H.1
Nakajima, Y.2
Kurihara, Y.3
|