Volumn 17, Issue 5, 2010, Pages 1649-1656

Partial discharge-induced degradation characteristics of insulating structure constituting oil-immersed power transformers

Author keywords

and insulation degradation; harmful partial discharge level; insulating element model; Oil immersed power transformer; partial discharge (PD); press board (PB); residual lightning impulse withstand voltage

Indexed keywords

HARMFUL PARTIAL DISCHARGE LEVEL; INSULATING ELEMENT MODEL; INSULATION DEGRADATION; OIL-IMMERSED POWER TRANSFORMERS; PRESS-BOARD (PB); RESIDUAL LIGHTNING IMPULSE WITHSTAND VOLTAGE;

EID: 77957903388     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2010.5595570     Document Type: Article
Times cited : (28)

References (11)
  • 3
    • 77955589061 scopus 로고
    • Study on harmful and harmless corona of power transformer insulation
    • M. Higaki, and Y. Tsutsumi, "Study on Harmful and Harmless Corona of Power Transformer Insulation", Tokyo Branch Convention of IEEJ, No. 175, 1969.
    • (1969) Tokyo Branch Convention of IEEJ , Issue.175
    • Higaki, M.1    Tsutsumi, Y.2
  • 5
    • 0015125461 scopus 로고
    • Behavior of oil corona and damage of transformer insulation
    • N. Izeki, A. Kurahashi, and K. Matsumura, "Behavior of Oil Corona and Damage of Transformer Insulation", IEEE, Trans. Power App. Syst., Vol. 90, pp. 2330-2338, 1971.
    • (1971) IEEE, Trans. Power App. Syst. , vol.90 , pp. 2330-2338
    • Izeki, N.1    Kurahashi, A.2    Matsumura, K.3
  • 6
    • 77955578081 scopus 로고    scopus 로고
    • Partial discharge-induced degradation characteristics of oil-impregnated insulating material used in oil-immersed power transformers
    • Paper 2666
    • S. Okabe, G. Ueta, H. Wada, and H. Okubo, "Partial Discharge-induced Degradation Characteristics of Oil-impregnated Insulating Material Used in Oil-immersed Power Transformers", IEEE, Trans. Dielectr. Electr. Insul., Vol. 17, 2010 (Paper 2666).
    • (2010) IEEE, Trans. Dielectr. Electr. Insul. , vol.17
    • Okabe, S.1    Ueta, G.2    Wada, H.3    Okubo, H.4
  • 7
    • 78650007575 scopus 로고    scopus 로고
    • Partial discharge-induced degradation characteristics of insulating materials of gas-filled power transformers
    • in review Paper 2478
    • S. Okabe, G. Ueta, H. Wada, and H. Okubo, "Partial Discharge-induced Degradation Characteristics of Insulating Materials of Gas-filled Power Transformers", IEEE, Trans. Dielectr. Electr. Insul., in review (Paper 2478).
    • IEEE, Trans. Dielectr. Electr. Insul.
    • Okabe, S.1    Ueta, G.2    Wada, H.3    Okubo, H.4
  • 8
    • 77955570401 scopus 로고    scopus 로고
    • Deterioration characteristics due to partial discharges in insulating structure constituting gas-filled power transformers
    • Paper 2524
    • S. Okabe, G. Ueta, H. Wada, and H. Okubo, "Deterioration Characteristics Due to Partial Discharges in Insulating Structure Constituting Gas-filled Power Transformers", IEEE, Trans. Dielectr. Electr. Insul., Vol. 17, 2010 (Paper 2524).
    • (2010) IEEE, Trans. Dielectr. Electr. Insul. , vol.17
    • Okabe, S.1    Ueta, G.2    Wada, H.3    Okubo, H.4
  • 11
    • 42149121403 scopus 로고    scopus 로고
    • Cross-equipment evaluation of partial discharge measurement and diagnosis techniques in electric power apparatus for transmission and distribution
    • DOI 10.1109/TDEI.2008.4483471, 4483471
    • M. Hikita, S. Okabe, H. Murase, and H. Okubo, "Cross-equipment Evaluation of Partial Discharge Measurement and Diagnosis Techniques in Electric Power Apparatus for Transmission and Distribution", IEEE, Trans. Dielectr. Electr. Insul., Vol. 15, pp. 505-518, 2008. (Pubitemid 351540663)
    • (2008) IEEE Transactions on Dielectrics and Electrical Insulation , vol.15 , Issue.2 , pp. 505-518
    • Hikita, M.1    Okabe, S.2    Murase, H.3    Okubo, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.