메뉴 건너뛰기




Volumn , Issue , 2010, Pages 1502-1507

Comparison of Wind Turbine LQG controllers designed to alleviate fatigue loads

Author keywords

[No Author keywords available]

Indexed keywords

CONTROL MODEL; CONTROL OBJECTIVES; CONTROL VARIABLE; DRIVE TRAIN; ELECTROMAGNETIC TORQUES; FATIGUE LOADS; FULL-LOAD; HORIZONTAL AXIS WIND TURBINES; LINEAR QUADRATIC GAUSSIAN CONTROLLERS; LQG CONTROLLER; MINER'S RULE; OPTIMIZATION CRITERIA; PITCH ANGLE; RAINFLOW; SIMPLE BEHAVIORS; VARIABLE SPEED;

EID: 77957886541     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICCA.2010.5524385     Document Type: Conference Paper
Times cited : (12)

References (10)
  • 1
    • 77957012641 scopus 로고    scopus 로고
    • Analysis of tower-blade interaction in the cancellation of the tower fore-aft mode via control
    • (London, U.K.), EWEA, November
    • Leithead. W and Dominguez. S, Analysis of tower-blade interaction in the cancellation of the tower fore-aft mode via control, in European Wind Energy Conference, (London, U.K.), EWEA, November 2004.
    • (2004) European Wind Energy Conference
    • Leithead, W.1    Dominguez, S.2
  • 3
  • 4
    • 51349169151 scopus 로고    scopus 로고
    • Alleviation of wind turbines loads with a LQG controller associated to intelligent micro sensors industrial technology
    • IEEE International Conference on volume, Issue, 15-17 Dec. 2006
    • Lescher, F.; Camblong, H.; Briand, R.; Curea, O. Alleviation of Wind Turbines Loads with a LQG Controller associated to Intelligent Micro Sensors Industrial Technology, 2006. ICIT 2006. IEEE International Conference on volume, Issue, 15-17 Dec. 2006 Page(s):654-659.
    • (2006) ICIT 2006 , pp. 654-659
    • Lescher, F.1    Camblong, H.2    Briand, R.3    Curea, O.4
  • 5
    • 0036978358 scopus 로고    scopus 로고
    • Large band simulation of the wind speed for real time wind turbine simulators
    • Nichita C, Luca. D, Dakyo. B, and Ceanga. E, "Large band simulation of the wind speed for real time wind turbine simulators," IEEE Transactions on Energy Conversion, Vol. 17, 2002, pp. 523-529.
    • (2002) IEEE Transactions on Energy Conversion , vol.17 , pp. 523-529
    • Nichita, C.1    Luca, D.2    Dakyo, B.3    Ceanga, E.4
  • 6
    • 0023324624 scopus 로고
    • A new definition of the rainflow cycle counting method
    • Rychlik I, A New Definition of the Rainflow Cycle Counting Method, Intl. Journal of Fatigue, Vol. 9, pp. 119-121, 1987.
    • (1987) Intl. Journal of Fatigue , vol.9 , pp. 119-121
    • Rychlik, I.1
  • 7
    • 0001770844 scopus 로고
    • Fatigue prediction for complicated stress-strain histories
    • Dowling. E. N, Fatigue Prediction for Complicated Stress-Strain Histories, Journal of Materials, Vol. 7, pp. 71-87, 1972.
    • (1972) Journal of Materials , vol.7 , pp. 71-87
    • Dowling, E.N.1
  • 8
    • 0005330815 scopus 로고    scopus 로고
    • Standard practices for cycle counting in fatigue analysis
    • ASTM E 1049-85 (Reapproved 1997) 03.01, Philadelphia
    • ASTM E 1049-85 (Reapproved 1997), Standard practices for cycle counting in fatigue analysis, in: Annual Book of ASTM Standards, Vol. 03.01, Philadelphia 1999, pp. 710-718.
    • (1999) Annual Book of ASTM Standards , pp. 710-718
  • 10
    • 77950837094 scopus 로고    scopus 로고
    • Active control: Wind turbine model
    • Risø National Laboratory, Roskilde, Denmark
    • Bindner, H. (1999). Active control: wind turbine model. Technical Report RISO-R-920(EN), Risø National Laboratory, Roskilde, Denmark.
    • (1999) Technical Report RISO-R-920(EN)
    • Bindner, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.