메뉴 건너뛰기




Volumn 184, Issue 1-3, 2010, Pages 20-25

Carbon composite-PVC based membrane coated platinum electrode for chromium determination

Author keywords

1 (2 (1H Imidazole 1 yl) 1 (4 methoxyphenyl)ethylidene) 2 phenyl hydrazine; Carbon composite; Chromium; Coated platinum electrode; PVC membrane

Indexed keywords

1-(2-(1H-IMIDAZOLE-1-YL)-1-(4-METHOXYPHENYL)ETHYLIDENE)-2-PHENYL HYDRAZINE; 1H-IMIDAZOLE; CARBON COMPOSITE; CARBON COMPOSITES; COATED PLATINUM ELECTRODE; DETECTION LIMITS; HOMOGENIZATION PROCEDURE; INDICATOR ELECTRODES; MINERAL WATER; NON-AQUEOUS MEDIUM; PH INDEPENDENT; PH RANGE; PLATINUM ELECTRODES; POTENTIOMETRIC TITRATIONS; PVC MEMBRANE; PVC-BASED MEMBRANES; SELECTIVE SENSORS; SHORT RESPONSE TIME; WIDE-LINEAR RANGE;

EID: 77957860150     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhazmat.2010.07.064     Document Type: Article
Times cited : (26)

References (34)
  • 1
    • 33846567494 scopus 로고    scopus 로고
    • Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores
    • Singh A.K., Gupta V.K., Gupta B. Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores. Anal. Chim. Acta 2007, 585:171-178.
    • (2007) Anal. Chim. Acta , vol.585 , pp. 171-178
    • Singh, A.K.1    Gupta, V.K.2    Gupta, B.3
  • 2
    • 5644253034 scopus 로고    scopus 로고
    • Estimation of trace amounts of chromium(III) in multi-vitamin with multi-mineral formulations
    • Sankalia J.M., Mashru R.C., Sankalia M.G., Parikh P.P., Sutariya V.B. Estimation of trace amounts of chromium(III) in multi-vitamin with multi-mineral formulations. Anal. Sci. 2004, 20:1321-1325.
    • (2004) Anal. Sci. , vol.20 , pp. 1321-1325
    • Sankalia, J.M.1    Mashru, R.C.2    Sankalia, M.G.3    Parikh, P.P.4    Sutariya, V.B.5
  • 3
    • 0004525765 scopus 로고
    • Preparation and analytical application of simple coated-wire cobalt (II) and chromium (III) ion-selective electrode
    • Masuda Y., Ishida E., Hiraga K. Preparation and analytical application of simple coated-wire cobalt (II) and chromium (III) ion-selective electrode. Nippon Kagaku Kaishi 1980, 1453.
    • (1980) Nippon Kagaku Kaishi , pp. 1453
    • Masuda, Y.1    Ishida, E.2    Hiraga, K.3
  • 4
    • 0006163791 scopus 로고
    • Precipitate based selective ion sensitive membrane electrodes for tripositive chromium and cadmium
    • Chattopadhyaya M.C. Precipitate based selective ion sensitive membrane electrodes for tripositive chromium and cadmium. J. Ind. Chem. Soc. 1989, 66:54.
    • (1989) J. Ind. Chem. Soc. , vol.66 , pp. 54
    • Chattopadhyaya, M.C.1
  • 5
    • 0030353029 scopus 로고    scopus 로고
    • Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions
    • Hassan S.S.M., Abbas M.N., Moustafa G.A.E. Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions. Talanta 1996, 43:797-804.
    • (1996) Talanta , vol.43 , pp. 797-804
    • Hassan, S.S.M.1    Abbas, M.N.2    Moustafa, G.A.E.3
  • 6
    • 0036173529 scopus 로고    scopus 로고
    • A new macrocyclic polystyrene-based sensor for chromium(III) ions Anal
    • Singh A.K., Panwar A., Singh R., Baniwal S.A. A new macrocyclic polystyrene-based sensor for chromium(III) ions Anal. Bioanal. Chem. 2002, 372:506-510.
    • (2002) Bioanal. Chem. , vol.372 , pp. 506-510
    • Singh, A.K.1    Panwar, A.2    Singh, R.3    Baniwal, S.A.4
  • 7
    • 0037327707 scopus 로고    scopus 로고
    • Novel potentiometric membrane sensor for the determination of trace amounts of chromium(III) ions
    • Ganjali M.R., Mizani F., Salavati-Niasari M., Javanbakht M. Novel potentiometric membrane sensor for the determination of trace amounts of chromium(III) ions. Anal. Sci. 2003, 19:235-238.
    • (2003) Anal. Sci. , vol.19 , pp. 235-238
    • Ganjali, M.R.1    Mizani, F.2    Salavati-Niasari, M.3    Javanbakht, M.4
  • 8
    • 2142657815 scopus 로고    scopus 로고
    • Coated graphite-epoxy ion-selective electrode for the determination of chromium(III) in oxalic medium
    • Khalil S., Wassel A.A., Belal F.F. Coated graphite-epoxy ion-selective electrode for the determination of chromium(III) in oxalic medium. Talanta 2004, 63:303-307.
    • (2004) Talanta , vol.63 , pp. 303-307
    • Khalil, S.1    Wassel, A.A.2    Belal, F.F.3
  • 9
    • 0032942333 scopus 로고    scopus 로고
    • Chromium(III)-selective electrode based on a macrocyclic compound
    • Singh A.K., Panwar A., Kumar S., Baniwal S. Chromium(III)-selective electrode based on a macrocyclic compound. Analyst 1999, 124:521-525.
    • (1999) Analyst , vol.124 , pp. 521-525
    • Singh, A.K.1    Panwar, A.2    Kumar, S.3    Baniwal, S.4
  • 10
    • 0035951531 scopus 로고    scopus 로고
    • Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene
    • Abbaspour A., Izadyar A. Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene. Talanta 2001, 53:1009-1013.
    • (2001) Talanta , vol.53 , pp. 1009-1013
    • Abbaspour, A.1    Izadyar, A.2
  • 11
    • 0142095149 scopus 로고    scopus 로고
    • Determination of trace amounts of Cr(III) in presence of Cr(VI) by a novel potentiometric membrane sensor based on a new tridenate S,N,O Schiff's base
    • Ganjali M.R., Emami M., Salavati-Niasari M., Yousefi M. Determination of trace amounts of Cr(III) in presence of Cr(VI) by a novel potentiometric membrane sensor based on a new tridenate S,N,O Schiff's base. Anal. Lett. 2003, 36:2735-2747.
    • (2003) Anal. Lett. , vol.36 , pp. 2735-2747
    • Ganjali, M.R.1    Emami, M.2    Salavati-Niasari, M.3    Yousefi, M.4
  • 12
    • 0037773252 scopus 로고    scopus 로고
    • Chromium(III) ion selective electrode based on glyoxal bis(2-hydroxyanil)
    • Gholivand M.B., Sharifpour F. Chromium(III) ion selective electrode based on glyoxal bis(2-hydroxyanil). Talanta 2003, 60:707-713.
    • (2003) Talanta , vol.60 , pp. 707-713
    • Gholivand, M.B.1    Sharifpour, F.2
  • 13
    • 15744363494 scopus 로고    scopus 로고
    • Development of a Cr(III)-specific potentiometric sensor using Aurin tricarboxylic acid modified silica
    • Sharma R.K., Goel A. Development of a Cr(III)-specific potentiometric sensor using Aurin tricarboxylic acid modified silica. Anal. Chim. Acta 2005, 534:137-142.
    • (2005) Anal. Chim. Acta , vol.534 , pp. 137-142
    • Sharma, R.K.1    Goel, A.2
  • 14
    • 18444419162 scopus 로고    scopus 로고
    • Tetraazacyclohexadeca macrocyclic ligand as a neutral carrier in a Cr ion-selective electrode
    • Singh A.K., Singh R., Saxena P. Tetraazacyclohexadeca macrocyclic ligand as a neutral carrier in a Cr ion-selective electrode. Sensors 2004, 4:187-195.
    • (2004) Sensors , vol.4 , pp. 187-195
    • Singh, A.K.1    Singh, R.2    Saxena, P.3
  • 16
    • 33748289509 scopus 로고    scopus 로고
    • Highly selective and sensitive chromium(III) membrane sensors based on 4-amino-3-hydrazine-6-methyl-1,2,4-triazin-5-one as a new neutral ionophore
    • Zamani H.A., Rajabzadeh G., Ganjali M.R. Highly selective and sensitive chromium(III) membrane sensors based on 4-amino-3-hydrazine-6-methyl-1,2,4-triazin-5-one as a new neutral ionophore. Sens. Actuators B 2006, 119:41-46.
    • (2006) Sens. Actuators B , vol.119 , pp. 41-46
    • Zamani, H.A.1    Rajabzadeh, G.2    Ganjali, M.R.3
  • 18
    • 33947292262 scopus 로고
    • Coated wire ion-selective electrodes
    • Cattrall R.W., Freiser H. Coated wire ion-selective electrodes. Anal. Chem. 1971, 43:1905-1906.
    • (1971) Anal. Chem. , vol.43 , pp. 1905-1906
    • Cattrall, R.W.1    Freiser, H.2
  • 19
    • 0011872831 scopus 로고
    • Carbon pastes for voltammetric detectors in high-performance liquid chromatography
    • Stulik K., Pocakova V., Starkova B. Carbon pastes for voltammetric detectors in high-performance liquid chromatography. J. Chromatogr. 1981, 213:41-46.
    • (1981) J. Chromatogr. , vol.213 , pp. 41-46
    • Stulik, K.1    Pocakova, V.2    Starkova, B.3
  • 20
    • 0030723091 scopus 로고    scopus 로고
    • A PVC-graphite composite electrode for electroanalytical use. Preparation and some applications
    • Albertus F., Alpizar A.J., Cerda V., Luque M., Riso A., Valcarcel M. A PVC-graphite composite electrode for electroanalytical use. Preparation and some applications. Anal. Chim. Acta 1997, 355:23-32.
    • (1997) Anal. Chim. Acta , vol.355 , pp. 23-32
    • Albertus, F.1    Alpizar, A.J.2    Cerda, V.3    Luque, M.4    Riso, A.5    Valcarcel, M.6
  • 21
    • 0035930424 scopus 로고    scopus 로고
    • Amperometric detection of cytochrome c by capillary electrophoresis at a sol-gel carbon composite electrode
    • Tan S.N., Hua L. Amperometric detection of cytochrome c by capillary electrophoresis at a sol-gel carbon composite electrode. Anal. Chim. Acta 2001, 450:263-267.
    • (2001) Anal. Chim. Acta , vol.450 , pp. 263-267
    • Tan, S.N.1    Hua, L.2
  • 22
    • 33750446703 scopus 로고    scopus 로고
    • Platinum electrode coated with a bentonite-carboncomposite as an environmental sensor for detection of lead
    • Abbaspour A., Izadyar A. Platinum electrode coated with a bentonite-carboncomposite as an environmental sensor for detection of lead. Anal. Bioanal. Chem. 2006, 386:1559-1565.
    • (2006) Anal. Bioanal. Chem. , vol.386 , pp. 1559-1565
    • Abbaspour, A.1    Izadyar, A.2
  • 23
    • 4944224410 scopus 로고    scopus 로고
    • Carbon composition PVC based membrane in a highly selective and sensitive coated wire electrode for silver ion
    • Abbaspour A., Izadyar A., Sharghi H. Carbon composition PVC based membrane in a highly selective and sensitive coated wire electrode for silver ion. Anal. Chim. Acta 2004, 525:91-96.
    • (2004) Anal. Chim. Acta , vol.525 , pp. 91-96
    • Abbaspour, A.1    Izadyar, A.2    Sharghi, H.3
  • 24
    • 77957880973 scopus 로고    scopus 로고
    • M.Sc Thesis, Shiraz University, Shiraz, Iran
    • S. Behrouz, M.Sc Thesis, Shiraz University, Shiraz, Iran, 2006.
    • (2006)
    • Behrouz, S.1
  • 25
    • 0035061816 scopus 로고    scopus 로고
    • Highly selective electrode for nickel (II) ion based on 1.5-diphenylthiocarbazone(dithizone)
    • Abbaspour A., Izadyar A. Highly selective electrode for nickel (II) ion based on 1.5-diphenylthiocarbazone(dithizone). Microchem. J. 2001, 69:7-11.
    • (2001) Microchem. J. , vol.69 , pp. 7-11
    • Abbaspour, A.1    Izadyar, A.2
  • 26
    • 0037170688 scopus 로고    scopus 로고
    • Copper(II)-selective electrode using thiuram disulfide neutral carriers
    • Abbaspour A., Kamyabi M.A. Copper(II)-selective electrode using thiuram disulfide neutral carriers. Anal. Chim. Acta 2002, 455:225-235.
    • (2002) Anal. Chim. Acta , vol.455 , pp. 225-235
    • Abbaspour, A.1    Kamyabi, M.A.2
  • 27
    • 33846398483 scopus 로고    scopus 로고
    • Carbon nanotube composite coated platinum electrode for detection of Cr(III) in real samples
    • Abbaspour A., Izadyar A. Carbon nanotube composite coated platinum electrode for detection of Cr(III) in real samples. Talanta 2007, 71:887-892.
    • (2007) Talanta , vol.71 , pp. 887-892
    • Abbaspour, A.1    Izadyar, A.2
  • 28
    • 72149119073 scopus 로고    scopus 로고
    • A highly selective and sensitive disposable carbon composite PVC-based membrane for determination of lead ion in environmental samples
    • Abbaspour A., Mirahmadi E., Khalafi-Nezhad A., Babamohammadi S. A highly selective and sensitive disposable carbon composite PVC-based membrane for determination of lead ion in environmental samples. J. Hazard. Mater. 2010, 174:656-661.
    • (2010) J. Hazard. Mater. , vol.174 , pp. 656-661
    • Abbaspour, A.1    Mirahmadi, E.2    Khalafi-Nezhad, A.3    Babamohammadi, S.4
  • 29
    • 77957881630 scopus 로고    scopus 로고
    • A selective and sensitive carbon composite coated platinum electrode for aluminium determination in pharmaceutical and mineral water samples, Anal. Chim. Acta, in press.
    • A. Abbaspour, M. Refahi, A. Khalafi-Nezhad, N. Soltani Rad, S. Behrouz, A selective and sensitive carbon composite coated platinum electrode for aluminium determination in pharmaceutical and mineral water samples, Anal. Chim. Acta, in press.
    • Abbaspour, A.1    Refahi, M.2    Khalafi-Nezhad, A.3    Soltani Rad, N.4    Behrouz, S.5
  • 30
    • 0024106504 scopus 로고
    • Copper(II)-selective electrode using thiuram disulfide neutral carriers
    • Kamata A., Bliale Y., Fukonago A., Murata Copper(II)-selective electrode using thiuram disulfide neutral carriers. Anal. Chem. 1988, 60:2464-2467.
    • (1988) Anal. Chem. , vol.60 , pp. 2464-2467
    • Kamata, A.1    Bliale, Y.2    Fukonago, A.3    Murata4
  • 31
    • 17844399370 scopus 로고
    • Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method
    • Gadzekpo P.Y., Christain G.D. Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method. Anal. Chim. Acta 1984, 164:279-282.
    • (1984) Anal. Chim. Acta , vol.164 , pp. 279-282
    • Gadzekpo, P.Y.1    Christain, G.D.2
  • 32
    • 0002232006 scopus 로고    scopus 로고
    • Selectivity of liquid membrane ion-selective electrodes
    • Bakker E. Selectivity of liquid membrane ion-selective electrodes. Electroanalysis 1997, 9:7-12.
    • (1997) Electroanalysis , vol.9 , pp. 7-12
    • Bakker, E.1
  • 33
    • 84876596105 scopus 로고
    • Selectivity coefficients for ion selective electrodes, recommended methods for reporting values
    • Umezawa K., Umezawa H., Sato H. Selectivity coefficients for ion selective electrodes, recommended methods for reporting values. Pure Appl. Chem. 1995, 67:507-518.
    • (1995) Pure Appl. Chem. , vol.67 , pp. 507-518
    • Umezawa, K.1    Umezawa, H.2    Sato, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.