메뉴 건너뛰기




Volumn 17, Issue 4, 2010, Pages 463-470

Initial clinical experience with the modified Zenith "Pro-Form" TX2 thoracic endograft

Author keywords

Thoracic aortic aneurysm; Thoracic aortic dissection; Thoracic endovascular aortic repair; Thoracic stent graft

Indexed keywords

ACUTE KIDNEY FAILURE; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DISEASE COURSE; DISEASE SEVERITY; ENDOLEAK; FEMALE; FOLLOW UP; HUMAN; INTERVENTIONAL CARDIOVASCULAR PROCEDURE; MALE; MORBIDITY; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PRO-FORM; RESPIRATORY FAILURE; SAFETY; STENT; THERAPY EFFECT; THORACIC AORTA ANEURYSM; THORACIC AORTIC ENDOVASCULAR REPAIR; ZENITH TX2 THORACIC STENT GRAFT;

EID: 77957828060     PISSN: 15266028     EISSN: 15451550     Source Type: Journal    
DOI: 10.1583/10-3061.1     Document Type: Article
Times cited : (27)

References (25)
  • 1
    • 38649140710 scopus 로고    scopus 로고
    • International controlled clinical trial of thoracic endovascular aneurysm repair with the Zenith TX2 endovascular graft: 1-year results
    • Matsumura JS, Cambria RP, Dake MD, et al. International controlled clinical trial of thoracic endovascular aneurysm repair with the Zenith TX2 endovascular graft: 1-year results. J Vasc Surg. 2008;47:247-257.
    • (2008) J Vasc Surg , vol.47 , pp. 247-257
    • Matsumura, J.S.1    Cambria, R.P.2    Dake, M.D.3
  • 2
    • 49749152060 scopus 로고    scopus 로고
    • Pivotal results of the Medtronic Vascular Talent Thoracic Stent Graft System: The VALOR Trial
    • Fairman RM, Criado F, Farber M, et al. Pivotal results of the Medtronic Vascular Talent Thoracic Stent Graft System: the VALOR Trial. J Vasc Surg. 2008;48:546-554.
    • (2008) J Vasc Surg , vol.48 , pp. 546-554
    • Fairman, R.M.1    Criado, F.2    Farber, M.3
  • 3
    • 13244258388 scopus 로고    scopus 로고
    • Endovascular treatment of thoracic aortic aneurysms: Results of the phase II multicenter trial of the GORE TAG thoracic prosthesis
    • Makaroun MS, Dillavou ED, Kee ST, et al. Endovascular treatment of thoracic aortic aneurysms: results of the phase II multicenter trial of the GORE TAG thoracic prosthesis. J Vasc Surg. 2005;41:1-9.
    • (2005) J Vasc Surg , vol.41 , pp. 1-9
    • Makaroun, M.S.1    Dillavou, E.D.2    Kee, S.T.3
  • 4
    • 68549122637 scopus 로고    scopus 로고
    • Magnitude and direction of pulsatile displacement forces acting on thoracic aortic endografts
    • Figueroa CA, Taylor CA, Chiou AJ, et al. Magnitude and direction of pulsatile displacement forces acting on thoracic aortic endografts. J Endovasc Ther. 2009;16:350-358.
    • (2009) J Endovasc Ther , vol.16 , pp. 350-358
    • Figueroa, C.A.1    Taylor, C.A.2    Chiou, A.J.3
  • 5
    • 77950917050 scopus 로고    scopus 로고
    • Factors favoring stent-graft collapse after thoracic endovascular aortic repair
    • Canaud L, Alric P, Desgranges P, et al. Factors favoring stent-graft collapse after thoracic endovascular aortic repair. J Thorac Cardiovasc Surg. 2010;139:1153-1157.
    • (2010) J Thorac Cardiovasc Surg , vol.139 , pp. 1153-1157
    • Canaud, L.1    Alric, P.2    Desgranges, P.3
  • 6
    • 67651087384 scopus 로고    scopus 로고
    • Infolding and collapse of thoracic endoprostheses: Manifestations and treatment options
    • Sze DY, Mitchell RS, Miller DC, et al. Infolding and collapse of thoracic endoprostheses: manifestations and treatment options. J Thorac Cardiovasc Surg. 2009;138:324-333.
    • (2009) J Thorac Cardiovasc Surg , vol.138 , pp. 324-333
    • Sze, D.Y.1    Mitchell, R.S.2    Miller, D.C.3
  • 7
    • 61349188471 scopus 로고    scopus 로고
    • Failure modes of thoracic endografts: Prevention and management
    • Lee WA. Failure modes of thoracic endografts: prevention and management. J Vasc Surg. 2009;49:792-799.
    • (2009) J Vasc Surg , vol.49 , pp. 792-799
    • Lee, W.A.1
  • 8
    • 64849112344 scopus 로고    scopus 로고
    • Endograft collapse after thoracic stent-graft repair for traumatic rupture
    • Lazar HL, Varma PK, Shapira OM, et al. Endograft collapse after thoracic stent-graft repair for traumatic rupture. Ann Thorac Surg. 2009;87:1582-1583.
    • (2009) Ann Thorac Surg , vol.87 , pp. 1582-1583
    • Lazar, H.L.1    Varma, P.K.2    Shapira, O.M.3
  • 9
    • 0348225069 scopus 로고    scopus 로고
    • Disappointing results with a new commercially available thoracic endograft
    • DOI 10.1016/S0741-5214(03)01034-6
    • Melissano G, Tshomba Y, Civilini E, et al. Disappointing results with a new commercially available thoracic endograft. J Vasc Surg. 2004;39:124-130. (Pubitemid 38056162)
    • (2004) Journal of Vascular Surgery , vol.39 , Issue.1 , pp. 124-130
    • Melissano, G.1    Tshomba, Y.2    Civilini, E.3    Chiesa, R.4
  • 10
    • 56049085646 scopus 로고    scopus 로고
    • Thoracic endovascular stent-graft with a bird's beak sign
    • Fayad A. Thoracic endovascular stent-graft with a bird's beak sign. Can J Anaesth. 2008;55:785-786.
    • (2008) Can J Anaesth , vol.55 , pp. 785-786
    • Fayad, A.1
  • 11
    • 71949109190 scopus 로고    scopus 로고
    • Staged proximal deployment of the Zenith TX2 thoracic stent-graft: A novel technique to improve conformance to the aortic arch
    • Kölbel T, Resch TA, Dias N, et al. Staged proximal deployment of the Zenith TX2 thoracic stent-graft: a novel technique to improve conformance to the aortic arch. J Endovasc Ther. 2009;16:598-602.
    • (2009) J Endovasc Ther , vol.16 , pp. 598-602
    • Kölbel, T.1    Resch, T.A.2    Dias, N.3
  • 12
    • 33644675208 scopus 로고    scopus 로고
    • Endovascular repair of proximal endograft collapse after treatment for thoracic aortic disease
    • Steinbauer MG, Stehr A, Pfister K, et al. Endovascular repair of proximal endograft collapse after treatment for thoracic aortic disease. J Vasc Surg. 2006;43:609-612.
    • (2006) J Vasc Surg , vol.43 , pp. 609-612
    • Steinbauer, M.G.1    Stehr, A.2    Pfister, K.3
  • 13
    • 33845206338 scopus 로고    scopus 로고
    • Management of aortic aneurysms and dissections with the Zenith TX2 stent graft
    • DOI 10.2310/6670.2006.00052
    • Lee WA. Management of aortic aneurysms and dissections with the Zenith TX2 stent graft. Vascular. 2006;14:282-289. (Pubitemid 44851369)
    • (2006) Vascular , vol.14 , Issue.5 , pp. 282-289
    • Lee, W.A.1
  • 14
    • 18144384766 scopus 로고    scopus 로고
    • Single center experience with a new commercially available thoracic endovascular graft
    • Melissano G, Civilini E, de Moura MR, et al. Single center experience with a new commercially available thoracic endovascular graft. Eur J Vasc Endovasc Surg. 2005;29:579-585.
    • (2005) Eur J Vasc Endovasc Surg , vol.29 , pp. 579-585
    • Melissano, G.1    Civilini, E.2    De Moura, M.R.3
  • 15
    • 45549100239 scopus 로고    scopus 로고
    • Thoracic aortic lesions treated with the Zenith TX1 and TX2 thoracic devices: Intermediate- and long-term outcomes
    • Morales JP, Greenberg RK, Morales CA, et al. Thoracic aortic lesions treated with the Zenith TX1 and TX2 thoracic devices: intermediate- and long-term outcomes. J Vasc Surg. 2008;48:54-63.
    • (2008) J Vasc Surg , vol.48 , pp. 54-63
    • Morales, J.P.1    Greenberg, R.K.2    Morales, C.A.3
  • 16
    • 0013308916 scopus 로고    scopus 로고
    • First International Summit on Thoracic Aortic Endografting: Roundtable on thoracic aortic dissection as an indication for endografting
    • Mitchell RS, Ishimaru S, Ehrlich MP, et al. First International Summit on Thoracic Aortic Endografting: roundtable on thoracic aortic dissection as an indication for endografting. J Endovasc Ther. 2002;9(suppl II):II-98-II105.
    • (2002) J Endovasc Ther , vol.9 , Issue.SUPPL. II
    • Mitchell, R.S.1    Ishimaru, S.2    Ehrlich, M.P.3
  • 17
    • 15044352366 scopus 로고    scopus 로고
    • OsiriX: An open-source software for navigating in multidimensional DICOM images
    • DOI 10.1007/s10278-004-1014-6
    • Rosset A, Spadola L, Ratib O. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging. 2004;17:205-216. (Pubitemid 40378992)
    • (2004) Journal of Digital Imaging , vol.17 , Issue.3 , pp. 205-216
    • Rosset, A.1    Spadola, L.2    Ratib, O.3
  • 18
    • 34248644601 scopus 로고    scopus 로고
    • Results of thoracic endovascular grafting in different aortic segments
    • Melissano G, Bertoglio L, Civilini E, et al. Results of thoracic endovascular grafting in different aortic segments. J Endovasc Ther. 2007;14:150-157.
    • (2007) J Endovasc Ther , vol.14 , pp. 150-157
    • Melissano, G.1    Bertoglio, L.2    Civilini, E.3
  • 19
    • 34047249954 scopus 로고    scopus 로고
    • Results of endografting of the aortic arch in different landing zones
    • Melissano G, Civilini E, Bertoglio L, et al. Results of endografting of the aortic arch in different landing zones. Eur J Vasc Endovasc Surg. 2007;33:561-566.
    • (2007) Eur J Vasc Endovasc Surg , vol.33 , pp. 561-566
    • Melissano, G.1    Civilini, E.2    Bertoglio, L.3
  • 20
    • 40349100312 scopus 로고    scopus 로고
    • Acute angulation of the aortic arch predisposes a patient to ascending aortic dilatation and aortic regurgitation late after the arterial switch operation for transposition of the great arteries
    • DOI 10.1016/j.jtcvs.2007.10.020, PII S002252230701728X
    • Agnoletti G, Phalla O, Celermajer D, et al. Acute angulation of the aortic arch predisposes a patient to ascending aortic dilatation and aortic regurgitation late after the arterial switch operation for transposition of the great arteries. J Thorac Cardiovasc Surg. 2008;135:568-572. (Pubitemid 351337613)
    • (2008) Journal of Thoracic and Cardiovascular Surgery , vol.135 , Issue.3 , pp. 568-572
    • Agnoletti, G.1    Ou, P.2    Celermajer, D.S.3    Boudjemline, Y.4    Marini, D.5    Bonnet, D.6    Aggoun, Y.7
  • 21
    • 19044393090 scopus 로고    scopus 로고
    • Reporting standards for endovascular aortic aneurysm repair
    • Chaikof EL, Blankensteijn JD, Harris PL, et al. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. 2002;35:1048-1060.
    • (2002) J Vasc Surg , vol.35 , pp. 1048-1060
    • Chaikof, E.L.1    Blankensteijn, J.D.2    Harris, P.L.3
  • 23
    • 33751578436 scopus 로고    scopus 로고
    • Thoracic aorta endografts: Variations in practice among medical specialists
    • Eggebrecht H, Pamler R, Zipfel B, et al. Thoracic aorta endografts: variations in practice among medical specialists. Catheter Cardiovasc Interv. 2006;68:843-852.
    • (2006) Catheter Cardiovasc Interv , vol.68 , pp. 843-852
    • Eggebrecht, H.1    Pamler, R.2    Zipfel, B.3
  • 24
    • 55449134612 scopus 로고    scopus 로고
    • European experience with Relay: A new stent-graft and delivery system for thoracic and arch lesions
    • Riambau V. European experience with Relay: a new stent-graft and delivery system for thoracic and arch lesions. J Cardiovasc Surg (Torino). 2008;49:407-415.
    • (2008) J Cardiovasc Surg (Torino) , vol.49 , pp. 407-415
    • Riambau, V.1
  • 25
    • 34250207397 scopus 로고    scopus 로고
    • Fenestrated and Branched Stent-Grafts for Thoracoabdominal, Pararenal and Juxtarenal Aortic Aneurysm Repair
    • DOI 10.1053/j.semvascsurg.2007.04.006, PII S0895796707000294, Changing Techniques in the Evaluation of Aortic Disease
    • Chuter TA. Fenestrated and branched stent-grafts for thoracoabdominal, pararenal and juxtarenal aortic aneurysm repair. Semin Vasc Surg. 2007;20:90-96. (Pubitemid 46908030)
    • (2007) Seminars in Vascular Surgery , vol.20 , Issue.2 , pp. 90-96
    • Chuter, T.A.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.