Volumn 38, Issue 17, 2010, Pages 96-100

Research of the power quality disturbance detection method based on forecasting mechanism

Author keywords

Detection; Linear prediction; Power quality disturbance

Indexed keywords

DETECTION; DETECTION ALGORITHM; DISTURBANCE SIGNALS; ELECTRICAL NETWORKS; LINEAR PREDICTION; LONG DURATION; POWER QUALITY DISTURBANCE; POWER QUALITY DISTURBANCES; PREDICTIVE FILTER; SUDDEN CHANGE; TIME DOMAIN POWER; TIME TRANSIENT; TRANSIENT DISTURBANCES; VOLTAGE SAGS; VOLTAGE SWELLS; WAVE FORMS;

EID: 77957800207     PISSN: 16743415     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (16)
  • 1
    • 77957757248 scopus 로고    scopus 로고
    • Design of customer power quality monitor based on network technology
    • WANG Bin, PAN Zhen-cun. Design of customer power quality monitor based on network technology[J]. Relay, 2004, 32(1): 54-57.
    • (2004) Relay , vol.32 , Issue.1 , pp. 54-57
    • Wang, B.1    Pan, Z.-C.2
  • 2
    • 34547966241 scopus 로고    scopus 로고
    • Application of wavelet transform and artificial neural network to power disturbance identification
    • LIN Tao, FAN Zheng-wei. Application of wavelet transform and artificial neural network to power disturbance identification[J]. High Voltage Engineering, 2007(7): 43-47.
    • (2007) High Voltage Engineering , Issue.7 , pp. 43-47
    • Lin, T.1    Fan, Z.-W.2
  • 3
    • 0030126570 scopus 로고    scopus 로고
    • Power quality assessment via wavelet transform analysis
    • Santoso S, Hofmann P. Power quality assessment via wavelet transform analysis[J]. IEEE Trans on Power Delivery, 1996, 11(2): 924-930.
    • (1996) IEEE Trans on Power Delivery , vol.11 , Issue.2 , pp. 924-930
    • Santoso, S.1    Hofmann, P.2
  • 4
    • 0030129262 scopus 로고    scopus 로고
    • Wavelets and electromagnetic power system transients
    • Robertson D C, Camps O I, Mayer J S, et al. Wavelets and electromagnetic power system transients[J]. IEEE Trans on Power Delivery, 1996, 11(2): 1050-1058.
    • (1996) IEEE Trans on Power Delivery , vol.11 , Issue.2 , pp. 1050-1058
    • Robertson, D.C.1    Camps, O.I.2    Mayer, J.S.3
  • 5
    • 0034289984 scopus 로고    scopus 로고
    • Wavelet based on-line disturbance detection for power quality applications
    • Karimi M, Mokhtari H, Reza M. Wavelet based on-line disturbance detection for power quality applications[J]. IEEE Trans on Power Delivery, 2000, 15(4): 1212-1220.
    • (2000) IEEE Trans on Power Delivery , vol.15 , Issue.4 , pp. 1212-1220
    • Karimi, M.1    Mokhtari, H.2    Reza, M.3
  • 6
    • 0033702414 scopus 로고    scopus 로고
    • An alternative method for transient analysis via wavelets
    • Sakis Meliopoulos A P, Lee Chien-Hsing. An alternative method for transient analysis via wavelets[J]. IEEE Trans on Power Delivery, 2000, 15(1): 114-121.
    • (2000) IEEE Trans on Power Delivery , vol.15 , Issue.1 , pp. 114-121
    • Sakis Meliopoulos, A.P.1    Lee, C.-H.2
  • 7
    • 0042774610 scopus 로고    scopus 로고
    • Detection and location of power quality disturbances using wavelet transform modulus maxma
    • HU Ming, CHEN Heng. Detection and location of power quality disturbances using wavelet transform modulus maxma[J]. Power System Technology, 2001, 25(3): 12-16.
    • (2001) Power System Technology , vol.25 , Issue.3 , pp. 12-16
    • Hu, M.1    Chen, H.2
  • 8
    • 2442691885 scopus 로고    scopus 로고
    • Power quality disturbance detection method using wavelet package transform based de-noising scheme
    • XUE Hui, YANG Ren-gang. Power quality disturbance detection method using wavelet package transform based de-noising scheme[J]. Proceedings of the CSEE, 2004, 24(3): 85-90.
    • (2004) Proceedings of the CSEE , vol.24 , Issue.3 , pp. 85-90
    • Xue, H.1    Yang, R.-G.2
  • 9
    • 0036819596 scopus 로고    scopus 로고
    • Wavelet-based measurements and classification of short duration power quality disturbances
    • CHENG Xiang-xun. Wavelet-based measurements and classification of short duration power quality disturbances[J]. Proceedings of the CSEE, 2002, 22(10): 1-6.
    • (2002) Proceedings of the CSEE , vol.22 , Issue.10 , pp. 1-6
    • Cheng, X.-X.1
  • 10
    • 67651036134 scopus 로고    scopus 로고
    • A simple and practical method of measuring short duration power quality disturbances
    • ZHU Tao-xi, JIANG Dao-shuo. A simple and practical method of measuring short duration power quality disturbances[J]. Relay, 2005, 33(7): 46-49.
    • (2005) Relay , vol.33 , Issue.7 , pp. 46-49
    • Zhu, T.-X.1    Jiang, D.-S.2
  • 11
    • 1442271516 scopus 로고    scopus 로고
    • A new method for detection of power quality disturbances
    • WEN Ji-feng, LIU Pei. A new method for detection of power quality disturbances[J]. Proceedings of the CSEE, 2002, 22(12): 17-20.
    • (2002) Proceedings of the CSEE , vol.22 , Issue.12 , pp. 17-20
    • Wen, J.-F.1    Liu, P.2
  • 12
    • 2542476415 scopus 로고    scopus 로고
    • Detection, localization and identification of power quality distuebance based on instantaneous reactive power theory
    • WEI Lei, ZHANG Fu-sheng, GENG Zhong-xing, et al. Detection, localization and identification of power quality distuebance based on instantaneous reactive power theory[J]. Power System Technology, 2004, 28(6): 53-58.
    • (2004) Power System Technology , vol.28 , Issue.6 , pp. 53-58
    • Wei, L.1    Zhang, F.-S.2    Geng, Z.-X.3
  • 13
    • 49049087848 scopus 로고    scopus 로고
    • A method for interharmonic measurement based on AR model spectral estimation and interpolation FFT algorithm
    • WANG Bo. A method for interharmonic measurement based on AR model spectral estimation and interpolation FFT algorithm[J]. Relay, 2006, 34(4): 49-52, 56.
    • (2006) Relay , vol.34 , Issue.4
    • Wang, B.1
  • 14
    • 4344575561 scopus 로고    scopus 로고
    • Research of correlated clutter AR model
    • ZHU Can-yan, HE Pei-kun. Research of correlated clutter AR model[J]. Modern Radar, 1998, 20(5): 36-43.
    • (1998) Modern Radar , vol.20 , Issue.5 , pp. 36-43
    • Zhu, C.-Y.1    He, P.-K.2
  • 15
    • 77957758303 scopus 로고    scopus 로고
    • Study on power quality detection method based on mathematical morphology
    • LI Yi-hong, HAN Fu-chun. Study on power quality detection method based on mathematical morphology[J]. Water Resources and Power, 2008, 36(3): 179-181.
    • (2008) Water Resources and Power , vol.36 , Issue.3 , pp. 179-181
    • Li, Y.-H.1    Han, F.-C.2
  • 16
    • 77957782300 scopus 로고    scopus 로고
    • Power quality detection method based on mathematical morphology and application
    • Wuhan: Huazhong University of Science and Technology
    • ZENG Ji-yong. Power quality detection method based on mathematical morphology and application[D]. Wuhan: Huazhong University of Science and Technology, 2005.
    • (2005)
    • Zeng, J.-Y.1