메뉴 건너뛰기




Volumn 21, Issue 10, 2010, Pages 1512-1520

Stent-grafts for transjugular intrahepatic portosystemic shunt creation: Specialized TIPS stent-graft versus generic stent-graft/bare stent combination

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ASCITES; BARE METAL STENT; BLADDER PUNCTURE; BLOOD CLOTTING DISORDER; BRAIN DISEASE; COMPARATIVE STUDY; CONTROLLED STUDY; DEMOGRAPHY; DISSEMINATED INTRAVASCULAR CLOTTING; DOPPLER ECHOGRAPHY; ESOPHAGUS VARICES BLEEDING; FEMALE; FOLLOW UP; GRAFT PATENCY; HEMATOMA; HEMODYNAMICS; HEMOPERITONEUM; HEPATIC ENCEPHALOPATHY; HUMAN; INFARCTION; KAPLAN MEIER METHOD; KIDNEY FAILURE; LIVER FAILURE; LIVER GRAFT; LIVER INFARCTION; LIVER INJURY; LIVER RUPTURE; LUNG EDEMA; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RADIATION INJURY; RETROSPECTIVE STUDY; SCORING SYSTEM; SEPSIS; STENT; TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT; VASCULAR PATENCY;

EID: 77957788882     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvir.2010.06.009     Document Type: Article
Times cited : (54)

References (26)
  • 1
    • 0036136358 scopus 로고    scopus 로고
    • Preliminary results of a new expanded-polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt procedures
    • P. Otal, T. Smayra, and C. Bureau Preliminary results of a new expanded-polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt procedures AJR Am J Roentgenol 178 2002 141 147
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 141-147
    • Otal, P.1    Smayra, T.2    Bureau, C.3
  • 2
    • 0034759522 scopus 로고    scopus 로고
    • Creation of transjugular intrahepatic portosystemic shunts with stent grafts: Initial experiences with a polytetrafluoroethylene-covered nitinol endoprosthesis
    • M. Cejna, M. Peck-Radosavljevic, and S. Thurnher Creation of transjugular intrahepatic portosystemic shunts with stent grafts: Initial experiences with a polytetrafluoroethylene-covered nitinol endoprosthesis Radiology 221 2001 437 446
    • (2001) Radiology , vol.221 , pp. 437-446
    • Cejna, M.1    Peck-Radosavljevic, M.2    Thurnher, S.3
  • 3
    • 0030659578 scopus 로고    scopus 로고
    • PTFE encapsulated endovascular stent-graft for transjugular intrahepatic portosystemic shunts: Experimental evaluation
    • Z.J. Haskal, A. Davis, A. McAllister, and E.E. Furth PTFE encapsulated endovascular stent-graft for transjugular intrahepatic portosystemic shunts: Experimental evaluation Radiology 205 1997 682 688
    • (1997) Radiology , vol.205 , pp. 682-688
    • Haskal, Z.J.1    Davis, A.2    McAllister, A.3    Furth, E.E.4
  • 4
    • 0032697875 scopus 로고    scopus 로고
    • Improved patency of transjugular intrahepatic portosystemic shunts in humans: Creation and revision with PTFE stent-grafts
    • Z.J. Haskal Improved patency of transjugular intrahepatic portosystemic shunts in humans: creation and revision with PTFE stent-grafts Radiology 213 1999 759 766
    • (1999) Radiology , vol.213 , pp. 759-766
    • Haskal, Z.J.1
  • 5
    • 0141643382 scopus 로고    scopus 로고
    • Survival in patients undergoing transjugular intrahepatic portosystemic shunt: ePTFE-covered stentgrafts versus bare stents
    • DOI 10.1053/jhep.2003.50423
    • B. Angermayr, M. Cejna, F. Koenig Vienna TIPS Study Group Survival in patients undergoing transjugular intrahepatic portosystemic shunt: ePTFE-covered stentgrafts versus bare stents Hepatology 38 2003 1043 1050 (Pubitemid 37221688)
    • (2003) Hepatology , vol.38 , Issue.4 , pp. 1043-1050
    • Angermayr, B.1    Cejna, M.2    Koenig, F.3    Karnel, F.4    Hackl, F.5    Gangl, A.6    Peck-Radosavljevic, M.7
  • 6
    • 0030825832 scopus 로고    scopus 로고
    • Stent-grafts for revisions of TIPS stenoses and occlusions: A clinical pilot study
    • R.R. Saxon, H. Timmermans, and B. Uchida Stent-grafts for revisions of TIPS stenoses and occlusions: a clinical pilot study J Vasc Interv Radiol 8 1997 539 548
    • (1997) J Vasc Interv Radiol , vol.8 , pp. 539-548
    • Saxon, R.R.1    Timmermans, H.2    Uchida, B.3
  • 7
    • 0036729128 scopus 로고    scopus 로고
    • EPTFE-covered stent-grafts for revision of obstructed transjugular intrahepatic portosystemic shunt
    • M. Cejna, M. Peck-Radosavljevic, and S. Thurnher ePTFE-covered stent-grafts for revision of obstructed transjugular intrahepatic portosystemic shunt Cardiovasc Intervent Radiol 25 2002 365 372
    • (2002) Cardiovasc Intervent Radiol , vol.25 , pp. 365-372
    • Cejna, M.1    Peck-Radosavljevic, M.2    Thurnher, S.3
  • 8
    • 1542373631 scopus 로고    scopus 로고
    • A new era for transjugular intrahepatic portosystemic shunts?
    • R.R. Saxon A new era for transjugular intrahepatic portosystemic shunts? J Vasc Interv Radiol 15 2004 217 219
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 217-219
    • Saxon, R.R.1
  • 9
    • 10744233609 scopus 로고    scopus 로고
    • Improved clinical outcome using polytetrafluoroethylene-coated stents for TIPS: Results of a randomized study
    • C. Bureau, J.C. Garcia-Pagan, and P. Otal Improved clinical outcome using polytetrafluoroethylene-coated stents for TIPS: results of a randomized study Gastroenterology 126 2004 469 475
    • (2004) Gastroenterology , vol.126 , pp. 469-475
    • Bureau, C.1    Garcia-Pagan, J.C.2    Otal, P.3
  • 10
    • 1442301513 scopus 로고    scopus 로고
    • Polytetrafluoroethylene-covered stent graft for TIPS procedure: 1-year patency and clinical results
    • S. Angeloni, M. Merli, and F.M. Salvatori Polytetrafluoroethylene-covered stent graft for TIPS procedure: 1-year patency and clinical results Am J Gastroenterol 99 2004 280 285
    • (2004) Am J Gastroenterol , vol.99 , pp. 280-285
    • Angeloni, S.1    Merli, M.2    Salvatori, F.M.3
  • 11
    • 2442664138 scopus 로고    scopus 로고
    • Polytetrafluoroethylene-covered Nitinol stent-graft for transjugular intrahepatic portosystemic shunt creation: 3-year experience
    • P. Rossi, F.M. Salvatori, and F. Fanelli Polytetrafluoroethylene-covered Nitinol stent-graft for transjugular intrahepatic portosystemic shunt creation: 3-year experience Radiology 231 2004 820 830
    • (2004) Radiology , vol.231 , pp. 820-830
    • Rossi, P.1    Salvatori, F.M.2    Fanelli, F.3
  • 12
    • 8444219997 scopus 로고    scopus 로고
    • Results of a retrospective multicenter trial of the Viatorr expended polytetrafluoroethylenecovered stent-graft for transjugular intrahepatic portosystemic shunt creation
    • J.P.M. Charon, F.H. Alaeddin, and S.A. Pimpalwar Results of a retrospective multicenter trial of the Viatorr expended polytetrafluoroethylenecovered stent-graft for transjugular intrahepatic portosystemic shunt creation J Vasc Interv Radiol 15 2004 1219 1230
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 1219-1230
    • Charon, J.P.M.1    Alaeddin, F.H.2    Pimpalwar, S.A.3
  • 13
    • 1542283694 scopus 로고    scopus 로고
    • Transjugular intrahepatic portosystemic shunt creation with the Viatorr expanded Polytetrafluoroethylene-covered stent-graft
    • K.A. Hausegger, F. Karnel, and B. Georgieva Transjugular intrahepatic portosystemic shunt creation with the Viatorr expanded Polytetrafluoroethylene- covered stent-graft J Vasc Interv Radiol 15 2004 239 248
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 239-248
    • Hausegger, K.A.1    Karnel, F.2    Georgieva, B.3
  • 14
    • 25644456868 scopus 로고    scopus 로고
    • TIPS with expanded polytetrafluoroethylene-covered stent: Results of an Italian multicenter study
    • C. Vignali, I. Bargellini, and M. Grosso TIPS with expanded polytetrafluoroethylene-covered stent: results of an Italian multicenter study AJR Am J Roentegenol 185 2005 472 480
    • (2005) AJR Am J Roentegenol , vol.185 , pp. 472-480
    • Vignali, C.1    Bargellini, I.2    Grosso, M.3
  • 15
    • 33748493763 scopus 로고    scopus 로고
    • The use of polytetrafluoroethylene-covered stent graft for transjugular intrahepatic portosystemic shunt (TIPS): Long-term follow-up of 100 patients
    • M. Rossle, V. Siegerstetter, and W. Euringer The use of polytetrafluoroethylene-covered stent graft for transjugular intrahepatic portosystemic shunt (TIPS): long-term follow-up of 100 patients Acta Radiol 47 2006 660 666
    • (2006) Acta Radiol , vol.47 , pp. 660-666
    • Rossle, M.1    Siegerstetter, V.2    Euringer, W.3
  • 16
    • 33644599455 scopus 로고    scopus 로고
    • Improved clinical outcome with transjugular intrahepatic portosystemic stent-shunt utilizing polytetrafluoroethylene-covered stent
    • D. Tripathi, J. Ferguson, and H. Barkell Improved clinical outcome with transjugular intrahepatic portosystemic stent-shunt utilizing polytetrafluoroethylene-covered stent Eur J Gastrenterol Hepatol 18 2006 225 232
    • (2006) Eur J Gastrenterol Hepatol , vol.18 , pp. 225-232
    • Tripathi, D.1    Ferguson, J.2    Barkell, H.3
  • 17
    • 34447307644 scopus 로고    scopus 로고
    • Patency of stents covered with polytetrafluoroethylene in patients treated by transjugular intrahepatic portosystemic shunts: Long-term results of a randomized multicentre study
    • C. Bureau, and J.C. Pagan Patency of stents covered with polytetrafluoroethylene in patients treated by transjugular intrahepatic portosystemic shunts: long-term results of a randomized multicentre study Liver Int 27 2007 742 747
    • (2007) Liver Int , vol.27 , pp. 742-747
    • Bureau, C.1    Pagan, J.C.2
  • 18
    • 4544261782 scopus 로고    scopus 로고
    • Reporting standards for transjugular intrahepatic portosystemic shunts
    • Society of Interventional Radiology Technology Assessment Committee
    • Z.J. Haskal, C.R. Rees, E.J. Ring, R. Saxon, D. Sacks Society of Interventional Radiology Technology Assessment Committee Reporting standards for transjugular intrahepatic portosystemic shunts J Vasc Interv Radiol 14 Suppl 2003 S419 S426
    • (2003) J Vasc Interv Radiol , vol.14 , Issue.SUPPL.
    • Haskal, Z.J.1    Rees, C.R.2    Ring, E.J.3    Saxon, R.4    Sacks, D.5
  • 19
    • 0041886413 scopus 로고    scopus 로고
    • Doppler evaluation of transjugular intrahepatic portosystemic shunts
    • W.D. Middleton, S.A. Teefey, and M.D. Darcy Doppler evaluation of transjugular intrahepatic portosystemic shunts Ultrasound Q 19 2003 56 70
    • (2003) Ultrasound Q , vol.19 , pp. 56-70
    • Middleton, W.D.1    Teefey, S.A.2    Darcy, M.D.3
  • 20
    • 0031019466 scopus 로고    scopus 로고
    • Doppler sonographic findings associated with TIPS shunt malfunction
    • R.Y. Kanterman, M.D. Darcy, and W.D. Middleton Doppler sonographic findings associated with TIPS shunt malfunction AJR Am J Roentgenol 168 1997 467 472
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 467-472
    • Kanterman, R.Y.1    Darcy, M.D.2    Middleton, W.D.3
  • 22
    • 0032785090 scopus 로고    scopus 로고
    • Stent-grafts for de novo TIPS: Technique and early results
    • R.T. Andrews, R.R. Saxon, and R.D. Bloch Stent-grafts for de novo TIPS: technique and early results J Vasc Interv Radiol 10 1999 1371 1378
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 1371-1378
    • Andrews, R.T.1    Saxon, R.R.2    Bloch, R.D.3
  • 23
    • 0032813775 scopus 로고    scopus 로고
    • Recurrent TIPS failure associate with biliary fistulae: Treatment with PTFE-covered stents
    • D.Y. Sze, T. Vestring, and R.P. Liddell Recurrent TIPS failure associate with biliary fistulae: treatment with PTFE-covered stents Cardiovasc Intervent Radiol 22 1999 298 304
    • (1999) Cardiovasc Intervent Radiol , vol.22 , pp. 298-304
    • Sze, D.Y.1    Vestring, T.2    Liddell, R.P.3
  • 24
    • 0027688969 scopus 로고
    • Histopathological study of stenotic and occluded transjugular intrahepatic portosystemic shunts
    • J.M. LaBerge, L.D. Ferrell, E.J. Ring, and R.L. Gordon Histopathological study of stenotic and occluded transjugular intrahepatic portosystemic shunts J Vasc Interv Radiol 4 1993 779 786
    • (1993) J Vasc Interv Radiol , vol.4 , pp. 779-786
    • Laberge, J.M.1    Ferrell, L.D.2    Ring, E.J.3    Gordon, R.L.4
  • 25
    • 1342346532 scopus 로고    scopus 로고
    • The effect of initial shunt outflow position on patency of transjugular intrahepatic portosystemic shunts
    • T.W.I. Clark, R. Agarwal, Z.J. Haskal, and S.W. Stavropoulos The effect of initial shunt outflow position on patency of transjugular intrahepatic portosystemic shunts J Vasc Interv Radiol 15 2004 147 152
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 147-152
    • Clark, T.W.I.1    Agarwal, R.2    Haskal, Z.J.3    Stavropoulos, S.W.4
  • 26
    • 33748210700 scopus 로고    scopus 로고
    • Elective transjugular intrahepatic portosystemic shunts for immediate pre-transplant portal decompression in adult living related liver transplant recipient candidates: Preliminary results
    • W.E.A. Saad, N.E.A. Saad, and M.G. Davies Elective transjugular intrahepatic portosystemic shunts for immediate pre-transplant portal decompression in adult living related liver transplant recipient candidates: preliminary results J Vasc Interv Radiol 17 2006 995 1002
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 995-1002
    • Saad, W.E.A.1    Saad, N.E.A.2    Davies, M.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.