1
-
-
33847339687
-
Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
-
J. Aoki, G. Nakazawa, K. Tanabe, A. Hoye, H. Yamamoto, T. Nakayama, Y. Onuma, Y. Higashikuni, S. Otsuki, A. Yagishita, S. Yachi, H. Nakajima, and K. Hara Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation Catheter Cardiovasc Interv 69 2007 380 386
-
(2007)
Catheter Cardiovasc Interv
, vol.69
, pp. 380-386
-
-
Aoki, J.1
Nakazawa, G.2
Tanabe, K.3
Hoye, A.4
Yamamoto, H.5
Nakayama, T.6
Onuma, Y.7
Higashikuni, Y.8
Otsuki, S.9
Yagishita, A.10
Yachi, S.11
Nakajima, H.12
Hara, K.13
-
2
-
-
33847405288
-
Stent fracture associated with drug-eluting stents: Clinical characteristics and implications
-
M.S. Lee, D. Jurewitz, J. Aragon, J. Forrester, R.R. Makkar, and S. Kar Stent fracture associated with drug-eluting stents: clinical characteristics and implications Catheter Cardiovasc Interv 69 2007 387 394
-
(2007)
Catheter Cardiovasc Interv
, vol.69
, pp. 387-394
-
-
Lee, M.S.1
Jurewitz, D.2
Aragon, J.3
Forrester, J.4
Makkar, R.R.5
Kar, S.6
-
3
-
-
40949164300
-
The incidence and clinical impact of stent strut fractures developed after drug-eluting stent implantation
-
W.S. Chung, C.S. Park, K.B. Seung, P.J. Kim, J.M. Lee, B.K. Koo, Y.S. Jang, J.Y. Yang, J.H. Yoon, D.I. Kim, Y.W. Yoon, J.S. Park, Y.H. Cho, and S.J. Park The incidence and clinical impact of stent strut fractures developed after drug-eluting stent implantation Int J Cardiol 125 2008 325 331
-
(2008)
Int J Cardiol
, vol.125
, pp. 325-331
-
-
Chung, W.S.1
Park, C.S.2
Seung, K.B.3
Kim, P.J.4
Lee, J.M.5
Koo, B.K.6
Jang, Y.S.7
Yang, J.Y.8
Yoon, J.H.9
Kim, D.I.10
Yoon, Y.W.11
Park, J.S.12
Cho, Y.H.13
Park, S.J.14
-
4
-
-
42249108867
-
Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis?
-
F. Shaikh, R. Maddikunta, M. Djelmami-Hani, J. Solis, S. Allaqaband, and T. Bajwa Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis? Catheter Cardiovasc Interv 71 2008 614 618
-
(2008)
Catheter Cardiovasc Interv
, vol.71
, pp. 614-618
-
-
Shaikh, F.1
Maddikunta, R.2
Djelmami-Hani, M.3
Solis, J.4
Allaqaband, S.5
Bajwa, T.6
-
5
-
-
36949022503
-
Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation
-
M. Okumura, Y. Ozaki, J. Ishii, S. Kan, H. Naruse, S. Matsui, M. Ishikawa, K. Hattori, T. Gochi, T. Nakano, A. Yamada, S. Kato, S. Motoyama, M. Sarai, Y. Takagi, T.F. Ismail, M. Nomura, and H. Hishida Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation Circ J 71 2007 1669 1677
-
(2007)
Circ J
, vol.71
, pp. 1669-1677
-
-
Okumura, M.1
Ozaki, Y.2
Ishii, J.3
Kan, S.4
Naruse, H.5
Matsui, S.6
Ishikawa, M.7
Hattori, K.8
Gochi, T.9
Nakano, T.10
Yamada, A.11
Kato, S.12
Motoyama, S.13
Sarai, M.14
Takagi, Y.15
Ismail, T.F.16
Nomura, M.17
Hishida, H.18
-
7
-
-
0346732102
-
Stent fracture and restenosis in the drug-eluting stent era
-
G. Sianos, S. Hofma, J.M.R. Ligthart, F. Saia, A. Hoye, P.A. Lemos, and P.W. Serruys Stent fracture and restenosis in the drug-eluting stent era Catheter Cardiovasc Interv 61 2004 111 116
-
(2004)
Catheter Cardiovasc Interv
, vol.61
, pp. 111-116
-
-
Sianos, G.1
Hofma, S.2
Ligthart, J.M.R.3
Saia, F.4
Hoye, A.5
Lemos, P.A.6
Serruys, P.W.7
-
8
-
-
0006407254
-
WinBUGSa Bayesian modeling framework: Concepts, structure, and extensibility
-
A.J. Lunn, A. Thomas, N. Best, and D. Spiegelhalter WinBUGSa Bayesian modeling framework: concepts, structure, and extensibility Stat Comput 10 2000 325 337
-
(2000)
Stat Comput
, vol.10
, pp. 325-337
-
-
Lunn, A.J.1
Thomas, A.2
Best, N.3
Spiegelhalter, D.4
-
9
-
-
0000576595
-
Markov chains for exploring posterior distributions
-
L. Tierney Markov chains for exploring posterior distributions Ann Stat 22 1994 1701 1728
-
(1994)
Ann Stat
, vol.22
, pp. 1701-1728
-
-
Tierney, L.1
-
10
-
-
57549083305
-
Clinical characteristics of stent fracture after sirolimus-eluting stent implantation
-
T.H. Yang, D.I. Kim, S.G. Park, J.S. Seo, H.J. Cho, S.H. Seol, S.M. Kim, D.K. Kim, and D.S. Kim Clinical characteristics of stent fracture after sirolimus-eluting stent implantation Int J Cardiol 131 2009 212 216
-
(2009)
Int J Cardiol
, vol.131
, pp. 212-216
-
-
Yang, T.H.1
Kim, D.I.2
Park, S.G.3
Seo, J.S.4
Cho, H.J.5
Seol, S.H.6
Kim, S.M.7
Kim, D.K.8
Kim, D.S.9
-
11
-
-
63149156312
-
Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation
-
H. Umeda, T. Gochi, M. Iwase, H. Izawa, T. Shimizu, R. Ishiki, H. Inagaki, J. Toyama, M. Yokota, and T. Murohara Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation Int J Cardiol 133 2009 321 326
-
(2009)
Int J Cardiol
, vol.133
, pp. 321-326
-
-
Umeda, H.1
Gochi, T.2
Iwase, M.3
Izawa, H.4
Shimizu, T.5
Ishiki, R.6
Inagaki, H.7
Toyama, J.8
Yokota, M.9
Murohara, T.10
-
12
-
-
63149164938
-
Incidence and predictors of drug-eluting stent fractures in long coronary disease
-
Long-DES-II Study Investigators S.J
-
H.S. Kim, Y.H. Kim, S.W. Lee, D.W. Park, C.W. Lee, M.K. Hong, S.W. Park, J.K. Ko, J.H. Park, J.H. Lee, S.W. Choi, I.W. Seong, Y.H. Cho, N.H. Lee, J.H. Kim, K.J. Chun, S.J. Park Long-DES-II Study Investigators Incidence and predictors of drug-eluting stent fractures in long coronary disease Int J Cardiol 133 2009 354 358
-
(2009)
Int J Cardiol
, vol.133
, pp. 354-358
-
-
Kim, H.S.1
Kim, Y.H.2
Lee, S.W.3
Park, D.W.4
Lee, C.W.5
Hong, M.K.6
Park, S.W.7
Ko, J.K.8
Park, J.H.9
Lee, J.H.10
Choi, S.W.11
Seong, I.W.12
Cho, Y.H.13
Lee, N.H.14
Kim, J.H.15
Chun, K.J.16
Park, S.J.17
-
13
-
-
54549119292
-
Serial angiographic and intravascular ultrasound analysis of late stent strut fracture of sirolimus-eluting stents in native coronary arteries
-
K.P. Yamada, T. Koizumi, H. Yamaguchi, H. Kaneda, H.N. Bonneau, Y. Honda, and P.J. Fitzgerald Serial angiographic and intravascular ultrasound analysis of late stent strut fracture of sirolimus-eluting stents in native coronary arteries Int J Cardiol 130 2008 255 259
-
(2008)
Int J Cardiol
, vol.130
, pp. 255-259
-
-
Yamada, K.P.1
Koizumi, T.2
Yamaguchi, H.3
Kaneda, H.4
Bonneau, H.N.5
Honda, Y.6
Fitzgerald, P.J.7
-
14
-
-
4544346302
-
Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis
-
A. Halkin, S. Carlier, and M.B. Leon Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis Heart 90 2004 e45
-
(2004)
Heart
, vol.90
, pp. 45
-
-
Halkin, A.1
Carlier, S.2
Leon, M.B.3
-
15
-
-
23844482954
-
Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization
-
DOI 10.1056/NEJMoa051175
-
S. Windecker, A. Remondino, F.R. Eberli, P. Jni, L. Rber, P. Wenaweser, M. Togni, M. Billinger, D. Tller, C. Seiler, M. Roffi, R. Corti, G. Stsch, W. Maier, T. Lscher, O.M. Hess, M. Egger, and B. Meier Sirolimus-eluting and paclitaxel-eluting stents for coronary revascularization N Engl J Med 353 2005 653 662 (Pubitemid 41175673)
-
(2005)
New England Journal of Medicine
, vol.353
, Issue.7
, pp. 653-662
-
-
Windecker, S.1
Remondino, A.2
Eberli, F.R.3
Juni, P.4
Raber, L.5
Wenaweser, P.6
Togni, M.7
Billinger, M.8
Tuller, D.9
Seiler, C.10
Roffi, M.11
Corti, R.12
Sutsch, G.13
Maier, W.14
Luscher, T.15
Hess, O.M.16
Egger, M.17
Meier, B.18
-
16
-
-
23844538250
-
Paclitaxel-eluting or sirolimus-eluting stents to prevent restenosis in diabetic patients
-
ISAR-DIABETES Study Investigators A
-
A. Dibra, A. Kastrati, J. Mehilli, J. Pache, H. Schhlen, N. von Beckerath, K. Ulm, R. Wessely, J. Dirschinger, A. Schmig ISAR-DIABETES Study Investigators Paclitaxel-eluting or sirolimus-eluting stents to prevent restenosis in diabetic patients N Engl J Med 353 2005 663 670
-
(2005)
N Engl J Med
, vol.353
, pp. 663-670
-
-
Dibra, A.1
Kastrati, A.2
Mehilli, J.3
Pache, J.4
Schhlen, H.5
Von Beckerath, N.6
Ulm, K.7
Wessely, R.8
Dirschinger, J.9
Schmig, A.10
-
17
-
-
34548523048
-
A meta-analysis of 16 randomized trials of sirolimus-eluting stents versus paclitaxel-eluting stents in patients with coronary artery disease
-
A. Schmig, A. Dibra, S. Windecker, J. Mehilli, J. Surez de Lezo, C. Kaiser, S.J. Park, J.J. Goy, J.H. Lee, E. Di Lorenzo, J. Wu, P. Jni, M.E. Pfisterer, B. Meier, and A. Kastrati A meta-analysis of 16 randomized trials of sirolimus-eluting stents versus paclitaxel-eluting stents in patients with coronary artery disease J Am Coll Cardiol 50 2007 1373 1380
-
(2007)
J Am Coll Cardiol
, vol.50
, pp. 1373-1380
-
-
Schmig, A.1
Dibra, A.2
Windecker, S.3
Mehilli, J.4
Surez De Lezo, J.5
Kaiser, C.6
Park, S.J.7
Goy, J.J.8
Lee, J.H.9
Di Lorenzo, E.10
Wu, J.11
Jni, P.12
Pfisterer, M.E.13
Meier, B.14
Kastrati, A.15
-
18
-
-
28844502833
-
Fatigue and life prediction for cobalt-chromium stents: A fracture mechanics analysis
-
R.V. Marrey, R. Burgermeister, R.B. Grishaber, and R.O. Ritchie Fatigue and life prediction for cobalt-chromium stents: a fracture mechanics analysis Biomaterials 27 2006 1988 2000
-
(2006)
Biomaterials
, vol.27
, pp. 1988-2000
-
-
Marrey, R.V.1
Burgermeister, R.2
Grishaber, R.B.3
Ritchie, R.O.4
-
19
-
-
34547669112
-
Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation
-
S.H. Lee, J.S. Park, D.G. Shin, Y.J. Kim, G.R. Hong, W. Kim, and B.S. Shim Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation Am J Cardiol 100 2007 627 630
-
(2007)
Am J Cardiol
, vol.100
, pp. 627-630
-
-
Lee, S.H.1
Park, J.S.2
Shin, D.G.3
Kim, Y.J.4
Hong, G.R.5
Kim, W.6
Shim, B.S.7
-
20
-
-
10644247669
-
Atherosclerosis imaging: Intravascular ultrasound
-
E.M. Tuzcu, and P. Schoenhagen Atherosclerosis imaging: intravascular ultrasound Drugs 64 suppl 2004 1 7
-
(2004)
Drugs
, vol.64
, Issue.SUPPL.
, pp. 1-7
-
-
Tuzcu, E.M.1
Schoenhagen, P.2
-
21
-
-
0035970098
-
Intravascular ultrasound: Novel pathophysiological insights and current clinical applications
-
S.E. Nissen, and P. Yock Intravascular ultrasound: novel pathophysiological insights and current clinical applications Circulation 103 2001 604 616
-
(2001)
Circulation
, vol.103
, pp. 604-616
-
-
Nissen, S.E.1
Yock, P.2
-
22
-
-
34447276381
-
Drug-eluting stent fracture occurred within 2 days after stent implantation
-
W.Y. Kang, W. Kim, H.G. Kim, and W. Kim Drug-eluting stent fracture occurred within 2 days after stent implantation Int J Cardiol 120 2007 273 275
-
(2007)
Int J Cardiol
, vol.120
, pp. 273-275
-
-
Kang, W.Y.1
Kim, W.2
Kim, H.G.3
Kim, W.4
-
23
-
-
0035312809
-
American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS): A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
-
G.S. Mintz, S.E. Nissen, W.D. Anderson, S.R. Bailey, R. Erbel, P.J. Fitzgerald, F.J. Pinto, K. Rosenfield, R.J. Siegel, E.M. Tuzcu, and P.G. Yock American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS) A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents J Am Coll Cardiol 37 2001 1478 1492
-
(2001)
J Am Coll Cardiol
, vol.37
, pp. 1478-1492
-
-
Mintz, G.S.1
Nissen, S.E.2
Anderson, W.D.3
Bailey, S.R.4
Erbel, R.5
Fitzgerald, P.J.6
Pinto, F.J.7
Rosenfield, K.8
Siegel, R.J.9
Tuzcu, E.M.10
Yock, P.G.11
|