Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
-
MPHYA6 0094-2405,. 10.1118/1.599009
-
D. A. Jaffray and J. H. Siewerdsen, " Cone-beam computed tomography with a flat-panel imager: Initial performance characterization.," Med. Phys. MPHYA6 0094-2405 27, 1311-1323 (2000). 10.1118/1.599009
-
(2000)
Med. Phys.
, vol.27
, pp. 1311-1323
-
-
Jaffray, D.A.1
Siewerdsen, J.H.2
-
2
-
-
0035053536
-
Effect of scattered radiation on image noise in cone beam CT
-
MPHYA6 0094-2405,. 10.1118/1.1357457
-
M. Endo, " Effect of scattered radiation on image noise in cone beam CT.," Med. Phys. MPHYA6 0094-2405 28, 469-474 (2001). 10.1118/1.1357457
-
(2001)
Med. Phys.
, vol.28
, pp. 469-474
-
-
Endo, M.1
-
3
-
-
0035110308
-
Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
-
MPHYA6 0094-2405,. 10.1118/1.1339879
-
J. H. Siewerdsen and D. A. Jaffray, " Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter.," Med. Phys. MPHYA6 0094-2405 28, 220-231 (2001). 10.1118/1.1339879
-
(2001)
Med. Phys.
, vol.28
, pp. 220-231
-
-
Siewerdsen, J.H.1
Jaffray, D.A.2
-
4
-
-
11244314035
-
The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors
-
MPHYA6 0094-2405,. 10.1118/1.1819789
-
J. H. Siewerdsen, " The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors.," Med. Phys. MPHYA6 0094-2405 31, 3506-3520 (2004). 10.1118/1.1819789
-
(2004)
Med. Phys.
, vol.31
, pp. 3506-3520
-
-
Siewerdsen, J.H.1
-
5
-
-
36048966383
-
Efficiency of antiscatter grids for flat-detector CT
-
PHMBA7 0031-9155,. 10.1088/0031-9155/52/20/013
-
Y. Kyriakou and W. Kalender, " Efficiency of antiscatter grids for flat-detector CT.," Phys. Med. Biol. PHMBA7 0031-9155 52, 6275-6293 (2007). 10.1088/0031-9155/52/20/013
-
(2007)
Phys. Med. Biol.
, vol.52
, pp. 6275-6293
-
-
Kyriakou, Y.1
Kalender, W.2
-
6
-
-
0026689155
-
Grids or air gaps for scatter reduction in digital radiography: A model calculation
-
MPHYA6 0094-2405,. 10.1118/1.596836
-
U. Neitzel, " Grids or air gaps for scatter reduction in digital radiography: A model calculation.," Med. Phys. MPHYA6 0094-2405 19, 475-481 (1992). 10.1118/1.596836
-
(1992)
Med. Phys.
, vol.19
, pp. 475-481
-
-
Neitzel, U.1
-
7
-
-
1842404803
-
Scatter rejection by air gaps in diagnostic radiology. Calculations using a Monte Carlo collision density method and consideration of molecular interference in coherent scattering
-
PHMBA7 0031-9155,. 10.1088/0031-9155/42/1/011
-
J. Persliden and G. A. Carlsson, " Scatter rejection by air gaps in diagnostic radiology. Calculations using a Monte Carlo collision density method and consideration of molecular interference in coherent scattering.," Phys. Med. Biol. PHMBA7 0031-9155 42, 155-175 (1997). 10.1088/0031-9155/42/1/011
-
(1997)
Phys. Med. Biol.
, vol.42
, pp. 155-175
-
-
Persliden, J.1
Carlsson, G.A.2
-
8
-
-
31044451240
-
A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT
-
MPHYA6 0094-2405,. 10.1118/1.2148916
-
J. H. Siewerdsen, " A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT.," Med. Phys. MPHYA6 0094-2405 33, 187-197 (2006). 10.1118/1.2148916
-
(2006)
Med. Phys.
, vol.33
, pp. 187-197
-
-
Siewerdsen, J.H.1
-
9
-
-
33645992417
-
Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy
-
PHMBA7 0031-9155,. 10.1088/0031-9155/51/9/005
-
C. J. Moore, T. E. Marchant, and A. M. Amer, " Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy.," Phys. Med. Biol. PHMBA7 0031-9155 51, 2191-2204 (2006). 10.1088/0031-9155/51/9/005
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 2191-2204
-
-
Moore, C.J.1
Marchant, T.E.2
Amer, A.M.3
-
10
-
-
2442689175
-
X-ray scatter correction algorithm for cone beam CT imaging
-
MPHYA6 0094-2405,. 10.1118/1.1711475
-
R. Ning, X. Tang, and D. Conover, " X-ray scatter correction algorithm for cone beam CT imaging.," Med. Phys. MPHYA6 0094-2405 31, 1195-1202 (2004). 10.1118/1.1711475
-
(2004)
Med. Phys.
, vol.31
, pp. 1195-1202
-
-
Ning, R.1
Tang, X.2
Conover, D.3
-
11
-
-
66749116737
-
Efficient scatter correction using asymmetric kernels
-
edited by E. Samei and J. Hsieh (SPIE, Bellingham, WA)
-
J. Star-Lack, " Efficient scatter correction using asymmetric kernels.," in Medical Imaging 2009: Physics of Medical Imaging. Proceedings of SPIE, edited by, E. Samei, and, J. Hsieh, (SPIE, Bellingham, WA, 2009), Vol. 7258, p. 72581Z.
-
(2009)
Medical Imaging 2009: Physics of Medical Imaging. Proceedings of SPIE
, vol.7258
-
-
Star-Lack, J.1
-
12
-
-
34347396603
-
Compensators for dose and scatter management in cone-beam computed tomography
-
MPHYA6 0094-2405,. 10.1118/1.2740466
-
S. A. Graham, " Compensators for dose and scatter management in cone-beam computed tomography.," Med. Phys. MPHYA6 0094-2405 34, 2691-2703 (2007). 10.1118/1.2740466
-
(2007)
Med. Phys.
, vol.34
, pp. 2691-2703
-
-
Graham, S.A.1
-
13
-
-
43149110640
-
Experimental validation of a Monte Carlo-based kV x-ray projection model for the Varian linac-mounted cone-beam CT imaging system
-
edited by J. Hsieh and E. Samei (SPIE, Bellingham, WA)
-
D. Lazos, " Experimental validation of a Monte Carlo-based kV x-ray projection model for the Varian linac-mounted cone-beam CT imaging system.," in Medical Imaging 2008: Physics of Medical Imaging. Proceedings of SPIE, edited by, J. Hsieh, and, E. Samei, (SPIE, Bellingham, WA, 2008), Vol. 6913, pp. 69133Q.
-
(2008)
Medical Imaging 2008: Physics of Medical Imaging. Proceedings of SPIE
, vol.6913
-
-
Lazos, D.1
-
14
-
-
0023727721
-
Dual-energy x-ray projection imaging: Two sampling schemes for the correction of scattered radiation
-
MPHYA6 0094-2405,. 10.1118/1.596188
-
F. C. Wagner, A. Macovski, and D. G. Nishimura, " Dual-energy x-ray projection imaging: Two sampling schemes for the correction of scattered radiation.," Med. Phys. MPHYA6 0094-2405 15, 732-748 (1988). 10.1118/1.596188
-
(1988)
Med. Phys.
, vol.15
, pp. 732-748
-
-
Wagner, F.C.1
MacOvski, A.2
Nishimura, D.G.3
-
15
-
-
0028281468
-
Scatter compensation in digital chest radiography using the posterior beam stop technique
-
MPHYA6 0094-2405,. 10.1118/1.597388
-
J. Y. Lo, " Scatter compensation in digital chest radiography using the posterior beam stop technique.," Med. Phys. MPHYA6 0094-2405 21, 435-443 (1999). 10.1118/1.597388
-
(1999)
Med. Phys.
, vol.21
, pp. 435-443
-
-
Lo, J.Y.1
-
16
-
-
33845562622
-
Scatter correction method for x-ray CT using primary modulation: Theory and preliminary results
-
ITMID4 0278-0062,. 10.1109/TMI.2006.884636
-
L. Zhu, N. R. Bennett, and R. Fahrig, " Scatter correction method for x-ray CT using primary modulation: Theory and preliminary results.," IEEE Trans. Med. Imaging ITMID4 0278-0062 25, 1573-1587 (2006). 10.1109/TMI.2006.884636
-
(2006)
IEEE Trans. Med. Imaging
, vol.25
, pp. 1573-1587
-
-
Zhu, L.1
Bennett, N.R.2
Fahrig, R.3
-
17
-
-
33745414296
-
Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations
-
MPHYA6 0094-2405,. 10.1118/1.2358324
-
G. Jarry, " Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations.," Med. Phys. MPHYA6 0094-2405 33, 4320-4329 (2006). 10.1118/1.2358324
-
(2006)
Med. Phys.
, vol.33
, pp. 4320-4329
-
-
Jarry, G.1
-
18
-
-
33748518881
-
Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT
-
PHMBA7 0031-9155,. 10.1088/0031-9155/51/18/008
-
Y. Kyriakou, T. Riedel, and W. A. Kalender, " Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT.," Phys. Med. Biol. PHMBA7 0031-9155 51, 4567-4586 (2006). 10.1088/0031-9155/51/18/008
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 4567-4586
-
-
Kyriakou, Y.1
Riedel, T.2
Kalender, W.A.3
-
19
-
-
76749107128
-
FW-CADIS method for variance reduction of Monte Carlo calculations of detailed distributions and multiple localized quantities
-
Saratoga Springs, NY, 3-7 May
-
J. C. Wagner, E. D. Blakeman, and D. E. Peplow, " FW-CADIS method for variance reduction of Monte Carlo calculations of detailed distributions and multiple localized quantities.," International Conference on Mathematics, Computational Methods and Reactor Physics, Saratoga Springs, NY, 3-7 May 2009.
-
(2009)
International Conference on Mathematics, Computational Methods and Reactor Physics
-
-
Wagner, J.C.1
Blakeman, E.D.2
Peplow, D.E.3
-
20
-
-
23844485364
-
Current status of the CBCT project at Varian Medical Systems
-
edited by M. J. Flynn (SPIE, Bellingham, WA)
-
E. Matsinos, " Current status of the CBCT project at Varian Medical Systems.," in Medical Imaging 2005: Physics of Medical Imaging. Proceedings of SPIE, edited by, M. J. Flynn, (SPIE, Bellingham, WA, 2005), Vol. 5745, pp. 340-351.
-
(2005)
Medical Imaging 2005: Physics of Medical Imaging. Proceedings of SPIE
, vol.5745
, pp. 340-351
-
-
Matsinos, E.1
-
21
-
-
38849155750
-
A dose comparison study between XVI and OBI CBCT systems
-
MPHYA6 0094-2405,. 10.1118/1.2825619
-
W. Y. Song, " A dose comparison study between XVI and OBI CBCT systems.," Med. Phys. MPHYA6 0094-2405 35, 480-486 (2008). 10.1118/1.2825619
-
(2008)
Med. Phys.
, vol.35
, pp. 480-486
-
-
Song, W.Y.1
-
22
-
-
0017328286
-
Noise due to photon counting statistics in computed x-ray tomography
-
JCATD5 0363-8715 (),. 10.1097/00004728-197701000-00009
-
D. A. Chesler, S. J. Riederer, and N. J. Pelc, " Noise due to photon counting statistics in computed x-ray tomography.," J. Comput. Assist. Tomogr. JCATD5 0363-8715 1 (1), 64-74 (1977). 10.1097/00004728-197701000-00009
-
(1977)
J. Comput. Assist. Tomogr.
, vol.1
, Issue.1
, pp. 64-74
-
-
Chesler, D.A.1
Riederer, S.J.2
Pelc, N.J.3
-
23
-
-
0021445363
-
Practical cone-beam algorithm
-
JOAOD6 0740-3232,. 10.1364/JOSAA.1.000612
-
L. A. Feldkamp, L. C. Davis, and J. W. Kress, " Practical cone-beam algorithm.," J. Opt. Soc. Am. A JOAOD6 0740-3232 1, 612-619 (1984). 10.1364/JOSAA.1.000612
-
(1984)
J. Opt. Soc. Am. A
, vol.1
, pp. 612-619
-
-
Feldkamp, L.A.1
Davis, L.C.2
Kress, J.W.3
-
24
-
-
0020030615
-
Scattered radiation in fan beam imaging systems
-
MPHYA6 0094-2405 (),. 10.1118/1.595076
-
P. C. Johns and M. Yaffe, " Scattered radiation in fan beam imaging systems.," Med. Phys. MPHYA6 0094-2405 9 (2), 231-239 (1982). 10.1118/1.595076
-
(1982)
Med. Phys.
, vol.9
, Issue.2
, pp. 231-239
-
-
Johns, P.C.1
Yaffe, M.2
-
25
-
-
35148827537
-
Evaluation of scatter mitigation strategies for x-ray cone-beam CT: Impact of scatter subtraction and anti-scatter grids on contrast-to-noise ratio
-
edited by J. Hsieh and M. J. Flynn (SPIE, Bellingham, WA)
-
D. Lazos, " Evaluation of scatter mitigation strategies for x-ray cone-beam CT: Impact of scatter subtraction and anti-scatter grids on contrast-to-noise ratio.," in Medical Imaging 2007: Physics of Medical Imaging. Proceedings of SPIE, edited by, J. Hsieh, and, M. J. Flynn, (SPIE, Bellingham, WA, 2007), Vol. 6510, pp. 65101V.
-
(2007)
Medical Imaging 2007: Physics of Medical Imaging. Proceedings of SPIE
, vol.6510
-
-
Lazos, D.1
-
26
-
-
37549072259
-
X-ray scattering in single- and dual-source CT
-
MPHYA6 0094-2405,. 10.1118/1.2820901
-
K. J. Engel, C. Herrmann, and G. Zeitler, " X-ray scattering in single- and dual-source CT.," Med. Phys. MPHYA6 0094-2405 35, 318-332 (2008). 10.1118/1.2820901
-
(2008)
Med. Phys.
, vol.35
, pp. 318-332
-
-
Engel, K.J.1
Herrmann, C.2
Zeitler, G.3
-
27
-
-
0018399326
-
Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector
-
PHMBA7 0031-9155,. 10.1088/0031-9155/24/3/002
-
R. Birch and M. Marshall, " Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector.," Phys. Med. Biol. PHMBA7 0031-9155 24, 505-517 (1979). 10.1088/0031-9155/24/3/002
-
(1979)
Phys. Med. Biol.
, vol.24
, pp. 505-517
-
-
Birch, R.1
Marshall, M.2
-
28
-
-
0023514509
-
Monte Carlo evaluation of kerma at a point for photon transport problems
-
MPHYA6 0094-2405,. 10.1118/1.596069
-
J. F. Williamson, " Monte Carlo evaluation of kerma at a point for photon transport problems.," Med. Phys. MPHYA6 0094-2405 14, 567-576 (1987). 10.1118/1.596069
-
(1987)
Med. Phys.
, vol.14
, pp. 567-576
-
-
Williamson, J.F.1
-
29
-
-
0025900734
-
Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds
-
MPHYA6 0094-2405,. 10.1118/1.596631
-
J. F. Williamson, " Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds.," Med. Phys. MPHYA6 0094-2405 18, 776-786 (1991). 10.1118/1.596631
-
(1991)
Med. Phys.
, vol.18
, pp. 776-786
-
-
Williamson, J.F.1
-
30
-
-
77957705207
-
-
edited by D. W. O. Rogers and J. Cygler (Medical Physics, Madison, WI)
-
J. F. Williamson and M. J. Rivard, in Clinical Dosimetry Measurements in Radiotherapy (AAPM 2009 Summer School), edited by, D. W. O. Rogers, and, J. Cygler, (Medical Physics, Madison, WI, 2009), pp. 437-499.
-
(2009)
Clinical Dosimetry Measurements in Radiotherapy (AAPM 2009 Summer School)
, pp. 437-499
-
-
Williamson, J.F.1
Rivard, M.J.2
-
31
-
-
0027139861
-
Calculation of photon mass energy-transfer and mass energy-absorption coefficients
-
RAREAE 0033-7587,. 10.2307/3578607
-
S. M. Seltzer, " Calculation of photon mass energy-transfer and mass energy-absorption coefficients.," Radiat. Res. RAREAE 0033-7587 136, 147-170 (1993). 10.2307/3578607
-
(1993)
Radiat. Res.
, vol.136
, pp. 147-170
-
-
Seltzer, S.M.1
-
32
-
-
0022362613
-
Prism representation: A 3D ray-tracing algorithm for radiotherapy applications
-
PHMBA7 0031-9155,. 10.1088/0031-9155/30/8/005
-
R. L. Siddon, " Prism representation: A 3D ray-tracing algorithm for radiotherapy applications.," Phys. Med. Biol. PHMBA7 0031-9155 30, 817-824 (1985). 10.1088/0031-9155/30/8/005
-
(1985)
Phys. Med. Biol.
, vol.30
, pp. 817-824
-
-
Siddon, R.L.1
-
33
-
-
0021040395
-
X-ray transmission formula for antiscatter grids
-
PHMBA7 0031-9155,. 10.1088/0031-9155/28/12/008
-
G. J. Day and D. R. Dance, " X-ray transmission formula for antiscatter grids.," Phys. Med. Biol. PHMBA7 0031-9155 28, 1429-1433 (1983). 10.1088/0031-9155/28/12/008
-
(1983)
Phys. Med. Biol.
, vol.28
, pp. 1429-1433
-
-
Day, G.J.1
Dance, D.R.2
-
34
-
-
0027450785
-
Comparison of calculated and measured heterogeneity correction factors for i 125, C 137 s and i 192 r brachytherapy sources near localized heterogeneities. (Winner of 1994 Farrington Daniels Award for best radiation dosimetry article published in Med. Phys. during 1993)
-
MPHYA6 0094-2405,. 10.1118/1.597088
-
J. F. Williamson, " Comparison of calculated and measured heterogeneity correction factors for I 125, C 137 s and I 192 r brachytherapy sources near localized heterogeneities. (Winner of 1994 Farrington Daniels Award for best radiation dosimetry article published in Med. Phys. during 1993).," Med. Phys. MPHYA6 0094-2405 20, 209-222 (1993). 10.1118/1.597088
-
(1993)
Med. Phys.
, vol.20
, pp. 209-222
-
-
Williamson, J.F.1
-
35
-
-
0029589221
-
Cone-beam CT for radiotherapy applications
-
PHMBA7 0031-9155,. 10.1088/0031-9155/40/11/007
-
P. S. Cho, R. H. Johnson, and T. W. Griffin, " Cone-beam CT for radiotherapy applications.," Phys. Med. Biol. PHMBA7 0031-9155 40, 1863-1883 (1995). 10.1088/0031-9155/40/11/007
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 1863-1883
-
-
Cho, P.S.1
Johnson, R.H.2
Griffin, T.W.3
-
36
-
-
0041374297
-
Simulation of scatter in cone beam CT: Effects on projection image quality
-
edited by M. J. Yaffe and L. E. Antonuk (SPIE, Bellingham, WA)
-
A. Malusek, M. P. Sandborg, and G. A. Carlsson, " Simulation of scatter in cone beam CT: Effects on projection image quality.," in Medical Imaging 2003: Physics of Medical Imaging. Proceedings of SPIE, edited by, M. J. Yaffe, and, L. E. Antonuk, (SPIE, Bellingham, WA, 2003), Vol. 5030, pp. 740-751.
-
(2003)
Medical Imaging 2003: Physics of Medical Imaging. Proceedings of SPIE
, vol.5030
, pp. 740-751
-
-
Malusek, A.1
Sandborg, M.P.2
Carlsson, G.A.3
-
37
-
-
3042593369
-
Performance of standard fluoroscopy anti-scatter grids in flat detector based cone beam CT
-
edited by M. J. Yaffe and M. J. Flynn (SPIE, Bellingham, WA)
-
J. Wiegert, " Performance of standard fluoroscopy anti-scatter grids in flat detector based cone beam CT.," in Medical Imaging 2004: Physics of Medical Imaging. Proceedings of SPIE, edited by, M. J. Yaffe, and, M. J. Flynn, (SPIE, Bellingham, WA, 2004), Vol. 5368, pp. 67-78.
-
(2004)
Medical Imaging 2004: Physics of Medical Imaging. Proceedings of SPIE
, vol.5368
, pp. 67-78
-
-
Wiegert, J.1
-
38
-
-
40049093127
-
Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy
-
MPHYA6 0094-2405,. 10.1118/1.2839096
-
G. X. Ding, D. M. Duggan, and C. W. Coffey, " Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy.," Med. Phys. MPHYA6 0094-2405 35, 1135-1144 (2008). 10.1118/1.2839096
-
(2008)
Med. Phys.
, vol.35
, pp. 1135-1144
-
-
Ding, G.X.1
Duggan, D.M.2
Coffey, C.W.3
-
39
-
-
34147169864
-
Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer
-
PHMBA7 0031-9155,. 10.1088/0031-9155/52/8/015
-
N. Wen, " Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer.," Phys. Med. Biol. PHMBA7 0031-9155 52, 2267-2276 (2007). 10.1088/0031-9155/52/8/015
-
(2007)
Phys. Med. Biol.
, vol.52
, pp. 2267-2276
-
-
Wen, N.1
-
40
-
-
58149115069
-
The influence of bowtie filtration on cone-beam CT image quality
-
MPHYA6 0094-2405,. 10.1118/1.3017470
-
N. Mail, " The influence of bowtie filtration on cone-beam CT image quality.," Med. Phys. MPHYA6 0094-2405 36, 22-32 (2009). 10.1118/1.3017470
-
(2009)
Med. Phys.
, vol.36
, pp. 22-32
-
-
Mail, N.1
-
41
-
-
77957719267
-
Cone beam CT beam hardening and scatter preprocessing for improved image quality in image-guided adaptive radiation therapy (Abstract TH-D-351-04 presented at AAPM 2008 annual meeting)
-
MPHYA6 0094-2405,. 10.1118/1.2962926
-
D. Zheng, " Cone beam CT beam hardening and scatter preprocessing for improved image quality in image-guided adaptive radiation therapy (Abstract TH-D-351-04 presented at AAPM 2008 annual meeting).," Med. Phys. MPHYA6 0094-2405 35, 2989 (2008). 10.1118/1.2962926
-
(2008)
Med. Phys.
, vol.35
, pp. 2989
-
-
Zheng, D.1
-
42
-
-
23844475227
-
Potential of software-based scatter corrections in cone-beam volume CT
-
edited by M. J. Flynn (SPIE, Bellingham, WA)
-
M. Bertram, J. Wiegert, and G. Rose, " Potential of software-based scatter corrections in cone-beam volume CT.," in Medical Imaging 2005: Physics of Medical Imaging. Proceedings of SPIE, edited by, M. J. Flynn, (SPIE, Bellingham, WA, 2005), Vol. 5745, pp. 259-269.
-
(2005)
Medical Imaging 2005: Physics of Medical Imaging. Proceedings of SPIE
, vol.5745
, pp. 259-269
-
-
Bertram, M.1
Wiegert, J.2
Rose, G.3
-
43
-
-
0031794571
-
Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
-
MPHYA6 0094-2405,. 10.1118/1.598410
-
J. Hsieh, " Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise.," Med. Phys. MPHYA6 0094-2405 25, 2139-2147 (1998). 10.1118/1.598410
-
(1998)
Med. Phys.
, vol.25
, pp. 2139-2147
-
-
Hsieh, J.1
-
44
-
-
45749103203
-
Dose reduction for kilovotage cone-beam computed tomography in radiation therapy
-
PHMBA7 0031-9155,. 10.1088/0031-9155/53/11/009
-
J. Wang, " Dose reduction for kilovotage cone-beam computed tomography in radiation therapy.," Phys. Med. Biol. PHMBA7 0031-9155 53, 2897-2909 (2008). 10.1088/0031-9155/53/11/009
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 2897-2909
-
-
Wang, J.1
-
45
-
-
21144458117
-
Penalized-likelihood sinogram smoothing for low-dose CT
-
MPHYA6 0094-2405,. 10.1118/1.1915015
-
P. J. La Rivìre, " Penalized-likelihood sinogram smoothing for low-dose CT.," Med. Phys. MPHYA6 0094-2405 32, 1676-1683 (2005). 10.1118/1.1915015
-
(2005)
Med. Phys.
, vol.32
, pp. 1676-1683
-
-
La Rivìre, P.J.1
-
46
-
-
0036680147
-
Flat-panel cone-beam computed tomography for image-guided radiation therapy
-
IOBPD3 0360-3016,. 10.1016/S0360-3016(02)02884-5
-
D. A. Jaffray, " Flat-panel cone-beam computed tomography for image-guided radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 53, 1337-1349 (2002). 10.1016/S0360-3016(02)02884-5
-
(2002)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.53
, pp. 1337-1349
-
-
Jaffray, D.A.1
-
47
-
-
85024820153
-
The investigation and correction of a bowtie-related cone-beam CT circular band artifact (Abstract TH-D-BRC-06 presented at AAPM 2009 Annual Meeting)
-
MPHYA6 0094-2405,. 10.1118/1.3182678
-
D. Zheng, " The investigation and correction of a bowtie-related cone-beam CT circular band artifact (Abstract TH-D-BRC-06 presented at AAPM 2009 Annual Meeting).," Med. Phys. MPHYA6 0094-2405 36, 2812 (2009). 10.1118/1.3182678
-
(2009)
Med. Phys.
, vol.36
, pp. 2812
-
-
Zheng, D.1
|