메뉴 건너뛰기




Volumn 30, Issue 4, 2010, Pages 1057-1067

Overranging at multisection CT: An underestimated source of excess radiation exposure

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BODY BURDEN; COMPUTER ASSISTED TOMOGRAPHY; ENVIRONMENTAL EXPOSURE; HUMAN; METHODOLOGY; RADIATION DOSE; RADIATION PROTECTION;

EID: 77957699574     PISSN: 02715333     EISSN: 15271323     Source Type: Journal    
DOI: 10.1148/rg.304095167     Document Type: Article
Times cited : (66)

References (22)
  • 1
    • 56149126478 scopus 로고    scopus 로고
    • Medical radiation exposure in the U.S. in 2006: Preliminary results
    • Mettler FA Jr, Thomadsen BR, Bhargavan M, et al. Medical radiation exposure in the U.S. in 2006: preliminary results. Health Phys 2008;95(5):502-507.
    • (2008) Health Phys , vol.95 , Issue.5 , pp. 502-507
    • Mettler Jr, F.A.1    Thomadsen, B.R.2    Bhargavan, M.3
  • 3
    • 0842348097 scopus 로고    scopus 로고
    • Risk of cancer from diagnostic X-rays: Estimates for the UK and 14 other countries
    • Berrington de González A, Darby S. Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet 2004;363(9406):345-351.
    • (2004) Lancet , vol.363 , Issue.9406 , pp. 345-351
    • de González, B.A.1    Darby, S.2
  • 4
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography: An increasing source of radiation exposure
    • Brenner DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med 2007;357(22):2277-2284.
    • (2007) N Engl J Med , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 5
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 Recommendations of the International Commission on Radiological Protection, ICRP publication 103
    • The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 2007;37(2-4):1-332.
    • (2007) Ann ICRP , vol.37 , Issue.2-4 , pp. 1-332
  • 6
    • 0033752732 scopus 로고    scopus 로고
    • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume
    • Boone JM, Cooper VN 3rd, Nemzek WR, McGahan JP, Seibert JA. Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume. Med Phys 2000;27(10): 2393-2407.
    • (2000) Med Phys , vol.27 , Issue.10 , pp. 2393-2407
    • Boone, J.M.1    Cooper, V.N.2    Nemzek, W.R.3    McGahan, J.P.4    Seibert, J.A.5
  • 7
    • 0036336399 scopus 로고    scopus 로고
    • Primary radiation outside the imaged volume of a multislice helical CT scan
    • Nicholson R, Fetherston S. Primary radiation outside the imaged volume of a multislice helical CT scan. Br J Radiol 2002;75(894):518-522.
    • (2002) Br J Radiol , vol.75 , Issue.894 , pp. 518-522
    • Nicholson, R.1    Fetherston, S.2
  • 8
    • 21144440833 scopus 로고    scopus 로고
    • The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations
    • Tzedakis A, Damilakis J, Perisinakis K, Stratakis J, Gourtsoyiannis N. The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations. Med Phys 2005;32(6):1621-1629.
    • (2005) Med Phys , vol.32 , Issue.6 , pp. 1621-1629
    • Tzedakis, A.1    Damilakis, J.2    Perisinakis, K.3    Stratakis, J.4    Gourtsoyiannis, N.5
  • 9
    • 36849012640 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: Technologic advances in multidetector CT with a focus on cardiac imaging
    • Cody DD, Mahesh M. AAPM/RSNA physics tutorial for residents: technologic advances in multidetector CT with a focus on cardiac imaging. RadioGraphics 2007;27(6):1829-1837.
    • (2007) RadioGraphics , vol.27 , Issue.6 , pp. 1829-1837
    • Cody, D.D.1    Mahesh, M.2
  • 10
    • 0031956821 scopus 로고    scopus 로고
    • Algorithm for image reconstruction in multi-slice helical CT
    • Taguchi K, Aradate H. Algorithm for image reconstruction in multi-slice helical CT. Med Phys 1998; 25(4):550-561.
    • (1998) Med Phys , vol.25 , Issue.4 , pp. 550-561
    • Taguchi, K.1    Aradate, H.2
  • 11
    • 33845655515 scopus 로고    scopus 로고
    • Overranging in multisection CT: Quantification and relative contribution to dose-comparison of four 16-section CT scanners
    • van der Molen AJ, Geleijns J. Overranging in multisection CT: quantification and relative contribution to dose-comparison of four 16-section CT scanners. Radiology 2007;242(1):208-216.
    • (2007) Radiology , vol.242 , Issue.1 , pp. 208-216
    • van der Molen, A.J.1    Geleijns, J.2
  • 12
    • 48649083246 scopus 로고    scopus 로고
    • The impact of scan length on the exposure levels in 16- and 64-row multidetector computed tomography: A phantom study
    • Irwan R, de Vries HB, Sijens PE. The impact of scan length on the exposure levels in 16- and 64-row multidetector computed tomography: a phantom study. Acad Radiol 2008;15(9):1142-1147.
    • (2008) Acad Radiol , vol.15 , Issue.9 , pp. 1142-1147
    • Irwan, R.1    de Vries, H.B.2    Sijens, P.E.3
  • 13
    • 0027141318 scopus 로고
    • Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy
    • Mackie TR, Holmes T, Swerdloff S, et al. Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. Med Phys 1993;20(6): 1709-1719.
    • (1993) Med Phys , vol.20 , Issue.6 , pp. 1709-1719
    • Mackie, T.R.1    Holmes, T.2    Swerdloff, S.3
  • 14
    • 46149125052 scopus 로고    scopus 로고
    • Minimization of over-ranging in helical volumetric CT via hybrid cone beam image reconstruction: Benefits in dose efficiency
    • Tang X, Hsieh J, Dong F, Fan J, Toth TL. Minimization of over-ranging in helical volumetric CT via hybrid cone beam image reconstruction: benefits in dose efficiency. Med Phys 2008;35(7):3232-3238.
    • (2008) Med Phys , vol.35 , Issue.7 , pp. 3232-3238
    • Tang, X.1    Hsieh, J.2    Dong, F.3    Fan, J.4    Toth, T.L.5
  • 15
    • 34147097370 scopus 로고    scopus 로고
    • Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations
    • Tzedakis A, Damilakis J, Perisinakis K, Karantanas A, Karabekios S, Gourtsoyiannis N. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations. Med Phys 2007;34(4):1163-1175.
    • (2007) Med Phys , vol.34 , Issue.4 , pp. 1163-1175
    • Tzedakis, A.1    Damilakis, J.2    Perisinakis, K.3    Karantanas, A.4    Karabekios, S.5    Gourtsoyiannis, N.6
  • 16
    • 34147097370 scopus 로고    scopus 로고
    • Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations
    • Tzedakis A, Damilakis J, Perisinakis K, Karantanas A, Karabekios S, Gourtsoyiannis N. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations. Med Phys 2007;34(4):1163-1175
    • (2007) Med Phys , vol.34 , Issue.4 , pp. 1163-1175
    • Tzedakis, A.1    Damilakis, J.2    Perisinakis, K.3    Karantanas, A.4    Karabekios, S.5    Gourtsoyiannis, N.6
  • 17
    • 0025930020 scopus 로고
    • 1990 Recommendations of the International Commission on Radiological Protection
    • 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 1991;21(1-3):1-201.
    • (1991) Ann ICRP , vol.21 , Issue.1-3 , pp. 1-201
  • 18
    • 25644442569 scopus 로고    scopus 로고
    • Measurement of CT radiation profile width using CR imaging plates
    • Liu HL, Liu RR, Reeve DM, Shepard SJ, Willis CE. Measurement of CT radiation profile width using CR imaging plates. Med Phys 2005;32(9):2881-2887.
    • (2005) Med Phys , vol.32 , Issue.9 , pp. 2881-2887
    • Liu, H.L.1    Liu, R.R.2    Reeve, D.M.3    Shepard, S.J.4    Willis, C.E.5
  • 20
    • 2342440042 scopus 로고    scopus 로고
    • Dose reduction to radiosensitive tissues in CT: Do commercially available shields meet the users' needs?
    • McLaughlin DJ, Mooney RB. Dose reduction to radiosensitive tissues in CT: do commercially available shields meet the users' needs? Clin Radiol 2004;59 (5):446-450.
    • (2004) Clin Radiol , vol.59 , Issue.5 , pp. 446-450
    • McLaughlin, D.J.1    Mooney, R.B.2
  • 21
    • 33748454831 scopus 로고    scopus 로고
    • Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    • Geleijns J, Salvadó Artells M, Veldkamp WJ, López Tortosa M, Calzado C.A. Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality. Eur Radiol 2006;16 (10):2334-2340.
    • (2006) Eur Radiol , vol.16 , Issue.10 , pp. 2334-2340
    • Geleijns, J.1    Salvadó, A.M.2    Veldkamp, W.J.3    López, T.M.4    Calzado, C.A.5
  • 22
    • 39149113136 scopus 로고    scopus 로고
    • CT urography: Definition, indications and techniques-a guideline for clinical practice
    • van Der Molen AJ, Cowan NC, Mueller-Lisse UG, et al. CT urography: definition, indications and techniques-a guideline for clinical practice. Eur Radiol 2008;18(1):4-17.
    • (2008) Eur Radiol , vol.18 , Issue.1 , pp. 4-17
    • van der Molen, A.J.1    Cowan, N.C.2    Mueller-Lisse, U.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.