메뉴 건너뛰기




Volumn 193, Issue 1, 2010, Pages 118-125

Autogenic EMG-controlled functional electrical stimulation for ankle dorsiflexion control

Author keywords

Drop foot; Gram Schmidt adaptive filter; Hemiparetic gait; Locomotion; M wave; Rehabilitation; Stimulation artefact

Indexed keywords

ADULT; ANKLE; ANKLE DORSIFLEXION CONTROL; ARTICLE; ELECTROMYOGRAM; FUNCTIONAL ELECTRICAL STIMULATION; HUMAN; HUMAN EXPERIMENT; JOINT FUNCTION; MALE; MUSCLE EXCITATION; MUSCLE ISOMETRIC CONTRACTION; NORMAL HUMAN; PRIORITY JOURNAL;

EID: 77957684680     PISSN: 01650270     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jneumeth.2010.08.011     Document Type: Article
Times cited : (56)

References (31)
  • 1
    • 0033868032 scopus 로고    scopus 로고
    • Electrical stimulation: can it increase muscle strength and reverse osteopenia in spinal cord injured individuals?
    • Belanger M., Stein R.B., Wheeler G.D., Gordon T., Leduc B. Electrical stimulation: can it increase muscle strength and reverse osteopenia in spinal cord injured individuals?. Arch Phys Med Rehabil 2000, 81:1090-1098.
    • (2000) Arch Phys Med Rehabil , vol.81 , pp. 1090-1098
    • Belanger, M.1    Stein, R.B.2    Wheeler, G.D.3    Gordon, T.4    Leduc, B.5
  • 3
    • 0020441124 scopus 로고
    • Development of a universal control unit for functional electrical-stimulation (FES)
    • Brandell B.R. Development of a universal control unit for functional electrical-stimulation (FES). Am J Phys Med Rehabil 1982, 61:279-301.
    • (1982) Am J Phys Med Rehabil , vol.61 , pp. 279-301
    • Brandell, B.R.1
  • 4
    • 0035002679 scopus 로고    scopus 로고
    • Does the drop-foot stimulator improve walking in hemiplegia?
    • Burridge J.H. Does the drop-foot stimulator improve walking in hemiplegia?. Neuromodulation 2001, 4:77-83.
    • (2001) Neuromodulation , vol.4 , pp. 77-83
    • Burridge, J.H.1
  • 5
    • 0030949380 scopus 로고    scopus 로고
    • Experience of clinical use of the Odstock dropped foot stimulator
    • Burridge J., Taylor P., Hagan S., Swain I. Experience of clinical use of the Odstock dropped foot stimulator. Artif Organs 1997, 21:254-260.
    • (1997) Artif Organs , vol.21 , pp. 254-260
    • Burridge, J.1    Taylor, P.2    Hagan, S.3    Swain, I.4
  • 6
    • 44649183937 scopus 로고    scopus 로고
    • Intralimb compensation strategy depends on the nature of joint perturbation in human hopping
    • Chang Y.H., Roiz R.A., Auyang A.G. Intralimb compensation strategy depends on the nature of joint perturbation in human hopping. J Biomech 2008, 41:1832-1839.
    • (2008) J Biomech , vol.41 , pp. 1832-1839
    • Chang, Y.H.1    Roiz, R.A.2    Auyang, A.G.3
  • 7
    • 0033822727 scopus 로고    scopus 로고
    • EMG signals detection and processing for on-line control of functional electrical stimulation
    • Frigo C., Ferrarin M., Frasson W., Pavan E., Thorsen R. EMG signals detection and processing for on-line control of functional electrical stimulation. J Electromyogr Kinesiol 2000, 10:351-360.
    • (2000) J Electromyogr Kinesiol , vol.10 , pp. 351-360
    • Frigo, C.1    Ferrarin, M.2    Frasson, W.3    Pavan, E.4    Thorsen, R.5
  • 9
    • 0031898820 scopus 로고    scopus 로고
    • Grasping in high lesioned tetraplegic subjects using the EMG controlled neuroprosthesis
    • Keller T., Curt A., Popovic M.R., Dietz V., Signer A. Grasping in high lesioned tetraplegic subjects using the EMG controlled neuroprosthesis. J Neurorehab 1998, 251-255.
    • (1998) J Neurorehab , pp. 251-255
    • Keller, T.1    Curt, A.2    Popovic, M.R.3    Dietz, V.4    Signer, A.5
  • 10
    • 0036323273 scopus 로고    scopus 로고
    • Increase in tibialis anterior motor cortex excitability following repetitive electrical stimulation of the common peroneal nerve
    • Khaslavskaia S., Ladouceur M., Sinkjaer T. Increase in tibialis anterior motor cortex excitability following repetitive electrical stimulation of the common peroneal nerve. Exp Brain Res 2002, 145:309-315.
    • (2002) Exp Brain Res , vol.145 , pp. 309-315
    • Khaslavskaia, S.1    Ladouceur, M.2    Sinkjaer, T.3
  • 11
    • 0344873307 scopus 로고    scopus 로고
    • Electrical stimulation of the human common peroneal nerve elicits lasting facilitation of cortical motor-evoked potentials
    • Knash M.E., Kido A., Gorassini M., Chan K.M., Stein R.B. Electrical stimulation of the human common peroneal nerve elicits lasting facilitation of cortical motor-evoked potentials. Exp Brain Res 2003, 153:366-377.
    • (2003) Exp Brain Res , vol.153 , pp. 366-377
    • Knash, M.E.1    Kido, A.2    Gorassini, M.3    Chan, K.M.4    Stein, R.B.5
  • 12
    • 34547476027 scopus 로고    scopus 로고
    • A randomized controlled trial of an implantable 2-channel peroneal nerve stimulator on walking speed and activity in poststroke hemiplegia
    • Kottink A.I., Hermens H.J., Nene A.V., Tenniglo M.J., van der Aa H.E., Buschman H.P., et al. A randomized controlled trial of an implantable 2-channel peroneal nerve stimulator on walking speed and activity in poststroke hemiplegia. Arch Phys Med Rehabil 2007, 88(8):971-978.
    • (2007) Arch Phys Med Rehabil , vol.88 , Issue.8 , pp. 971-978
    • Kottink, A.I.1    Hermens, H.J.2    Nene, A.V.3    Tenniglo, M.J.4    van der Aa, H.E.5    Buschman, H.P.6
  • 13
    • 2542458248 scopus 로고    scopus 로고
    • The orthotic effect of functional electrical stimulation on the improvement of walking in stroke patients with a dropped foot: a systematic review
    • Kottink A.I.R., Oostendorp L.J.M., Buurke J.H., Nene A.V., Hermens H.J., Ijzerman M.J. The orthotic effect of functional electrical stimulation on the improvement of walking in stroke patients with a dropped foot: a systematic review. Artif Organs 2004, 28:577-586.
    • (2004) Artif Organs , vol.28 , pp. 577-586
    • Kottink, A.I.R.1    Oostendorp, L.J.M.2    Buurke, J.H.3    Nene, A.V.4    Hermens, H.J.5    Ijzerman, M.J.6
  • 15
    • 73049136842 scopus 로고
    • Functional electrotherapy in stimulation of the peroneal nerve synchronized with the swing phase of gait in hemiparetic patients
    • Liberson W.T., Holmquest H.J., Scott D., Dow M. Functional electrotherapy in stimulation of the peroneal nerve synchronized with the swing phase of gait in hemiparetic patients. Arch Phys Med Rehabil 1961, 42:101-105.
    • (1961) Arch Phys Med Rehabil , vol.42 , pp. 101-105
    • Liberson, W.T.1    Holmquest, H.J.2    Scott, D.3    Dow, M.4
  • 18
    • 0038726879 scopus 로고    scopus 로고
    • Development of an EMG recording device from stimulation electrodes for functional electrical stimulation
    • Muraoka Y. Development of an EMG recording device from stimulation electrodes for functional electrical stimulation. Frontiers Med Biol Eng 2002, 11:323-333.
    • (2002) Frontiers Med Biol Eng , vol.11 , pp. 323-333
    • Muraoka, Y.1
  • 19
    • 0036231789 scopus 로고    scopus 로고
    • A versatile drop foot stimulator for research applications
    • January
    • O'Keeffe D.T., Lyons G.M. A versatile drop foot stimulator for research applications. Medical Engineering & Physics 2002, 24(January):237-242.
    • (2002) Medical Engineering & Physics , vol.24 , pp. 237-242
    • O'Keeffe, D.T.1    Lyons, G.M.2
  • 21
    • 0013220673 scopus 로고
    • Electrical-stimulation of paretic leg muscles in man, allowing feedback-controlled movements to be generated from the wrist
    • Prochazka A., Wiles C.M. Electrical-stimulation of paretic leg muscles in man, allowing feedback-controlled movements to be generated from the wrist. J Physiol (Lond) 1983, 343:P20-P21.
    • (1983) J Physiol (Lond) , vol.343
    • Prochazka, A.1    Wiles, C.M.2
  • 22
    • 0031170811 scopus 로고    scopus 로고
    • Functional neuromuscular stimulation controlled by surface electromyographic signals produced by volitional activation of the same muscle: adaptive removal of the muscle response from the recorded EMG signal
    • Sennels S., Biering-Sorensen F., Andersen O.T., Hansen S.D. Functional neuromuscular stimulation controlled by surface electromyographic signals produced by volitional activation of the same muscle: adaptive removal of the muscle response from the recorded EMG signal. IEEE Trans Biomed Eng 1997, 5:12.
    • (1997) IEEE Trans Biomed Eng , vol.5 , pp. 12
    • Sennels, S.1    Biering-Sorensen, F.2    Andersen, O.T.3    Hansen, S.D.4
  • 23
    • 0023378409 scopus 로고
    • An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle
    • Smith B.T., Peckham P.H., Keith M.W., Roscoe D.D. An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle. IEEE Trans Biomed Eng 1987, 34:499-508.
    • (1987) IEEE Trans Biomed Eng , vol.34 , pp. 499-508
    • Smith, B.T.1    Peckham, P.H.2    Keith, M.W.3    Roscoe, D.D.4
  • 26
    • 0016829641 scopus 로고
    • Experimental correction of footdrop by electrical-stimulation of peroneal nerve
    • Waters R.L., McNeal D., Perry J. Experimental correction of footdrop by electrical-stimulation of peroneal nerve. J Bone Joint Surg Am 1975, 57:1047-1054.
    • (1975) J Bone Joint Surg Am , vol.57 , pp. 1047-1054
    • Waters, R.L.1    McNeal, D.2    Perry, J.3
  • 27
    • 0021800935 scopus 로고
    • Functional electrical-stimulation of the peroneal nerve for hemiplegia-long-term clinical follow-up
    • Waters R.L., McNeal D.R., Faloon W., Clifford B. Functional electrical-stimulation of the peroneal nerve for hemiplegia-long-term clinical follow-up. J Bone Joint Surg Am 1985, 67A:792-793.
    • (1985) J Bone Joint Surg Am , vol.67 A , pp. 792-793
    • Waters, R.L.1    McNeal, D.R.2    Faloon, W.3    Clifford, B.4
  • 28
    • 0025063714 scopus 로고
    • Real-time gait assessment utilizing a new way of accelerometry
    • Willemsen A.T.M., Vanalste J.A., Boom H.B.K. Real-time gait assessment utilizing a new way of accelerometry. J Biomech 1990, 23:859-863.
    • (1990) J Biomech , vol.23 , pp. 859-863
    • Willemsen, A.T.M.1    Vanalste, J.A.2    Boom, H.B.K.3
  • 30
    • 26444544461 scopus 로고    scopus 로고
    • Gram-Schmidt M-wave canceller for the EMG controlled FES
    • Yeom H., Park Y., Yoon H Gram-Schmidt M-wave canceller for the EMG controlled FES. IEICE Trans Inform Syst 2005, E88D:2213-2217.
    • (2005) IEICE Trans Inform Syst , vol.E88D , pp. 2213-2217
    • Yeom, H.1    Park, Y.2    Yoon H3
  • 31
    • 36949008339 scopus 로고    scopus 로고
    • Eigen filter to detect volitional EMG signals in autogenic EMG-controlled FES
    • Yeom H.J., Park Y.C., Chang Y.H. Eigen filter to detect volitional EMG signals in autogenic EMG-controlled FES. Electron Lett 2007, 43:1410-1411.
    • (2007) Electron Lett , vol.43 , pp. 1410-1411
    • Yeom, H.J.1    Park, Y.C.2    Chang, Y.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.