메뉴 건너뛰기




Volumn 9, Issue 4-5, 2010, Pages 881-888

On-chip electro membrane extraction

Author keywords

Basic drugs; Electro membrane extraction; Human urine; On chip sample preparation

Indexed keywords

ANALYTES; BASIC DRUGS; BASIC MODELS; BIOLOGICAL SAMPLES; CHANNEL STRUCTURES; DEEP DONOR; DOWN-SCALING; DRUG SUBSTANCES; ELECTRO MEMBRANE EXTRACTION; ELECTRO-MEMBRANES; EXACT CONTROLS; FAST KINETICS; HIGH IONIC STRENGTH; HUMAN URINE; LARGE SPAN; MICRO-FLUIDIC DEVICES; ON CHIPS; ORGANIC PHASE; POLYPROPYLENE MEMBRANE; PRE-CONCENTRATION; PROTONATED; SAMPLE PREPARATION; SAMPLE SOLUTION; SELECTIVE EXTRACTION; SUPPORTED LIQUID MEMBRANE; VOLTAGE-CONTROLLED;

EID: 77957608923     PISSN: 16134982     EISSN: 16134990     Source Type: Journal    
DOI: 10.1007/s10404-010-0603-6     Document Type: Article
Times cited : (128)

References (31)
  • 3
    • 0141886232 scopus 로고    scopus 로고
    • The intensification of rapid reactions in multiphase systems using slug flow in capillaries
    • Burns JR, Ramshaw C (2001) The intensification of rapid reactions in multiphase systems using slug flow in capillaries. Lab Chip 1:10-15
    • (2001) Lab Chip , vol.1 , pp. 10-15
    • Burns, J.R.1    Ramshaw, C.2
  • 4
    • 29944435006 scopus 로고    scopus 로고
    • A microfluidic chip based liquid-liquid extraction system with microporous membrane
    • Cai ZX, Fang Q, Chen HW, Fang ZL (2006) A microfluidic chip based liquid-liquid extraction system with microporous membrane. Anal Chim Acta 556:151-156
    • (2006) Anal Chim Acta , vol.556 , pp. 151-156
    • Cai, Z.X.1    Fang, Q.2    Chen, H.W.3    Fang, Z.L.4
  • 5
    • 22144473266 scopus 로고    scopus 로고
    • Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter- droplet trapping technique
    • Chen H, Fang Q, Yin XF, Fang ZL (2005) Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter- droplet trapping technique. Lab Chip 5:719-725
    • (2005) Lab Chip , vol.5 , pp. 719-725
    • Chen, H.1    Fang, Q.2    Yin, X.F.3    Fang, Z.L.4
  • 6
    • 33746504559 scopus 로고    scopus 로고
    • Electrokinetic migration across artificial liquid membranes-tuning the membrane chemistry to different types of drug substances
    • Gjelstad A, Rasmussen KE, Pedersen-Bjergaard S (2006) Electrokinetic migration across artificial liquid membranes-tuning the membrane chemistry to different types of drug substances. J Chromatogr A 1124:29-34
    • (2006) J Chromatogr A , vol.1124 , pp. 29-34
    • Gjelstad, A.1    Rasmussen, K.E.2    Pedersen-Bjergaard, S.3
  • 7
    • 34250691597 scopus 로고    scopus 로고
    • Microextraction across supported liquid membranes forced by pH gradients and electrical fields
    • DOI 10.1016/j.chroma.2007.05.007, PII S0021967307008540
    • Gjelstad A, Andersen TM, Rasmussen KE, Pedersen-Bjergaard S (2007a) Microextraction across supported liquid membranes forced by pH gradients and electrical fields. J Chromatogr A 1157:38-45 (Pubitemid 46963308)
    • (2007) Journal of Chromatography A , vol.1157 , Issue.1-2 , pp. 38-45
    • Gjelstad, A.1    Andersen, T.M.2    Rasmussen, K.E.3    Pedersen-Bjergaard, S.4
  • 8
    • 36148929820 scopus 로고    scopus 로고
    • Simulation of flux during electro-membrane extraction based on the Nernst- Planck equation
    • Gjelstad A, Rasmussen KE, Pedersen-Bjergaard S (2007b) Simulation of flux during electro-membrane extraction based on the Nernst- Planck equation. J Chromatogr A 1174:104-111
    • (2007) J Chromatogr A , vol.1174 , pp. 104-111
    • Gjelstad, A.1    Rasmussen, K.E.2    Pedersen-Bjergaard, S.3
  • 9
    • 0036530672 scopus 로고    scopus 로고
    • Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels
    • Hibara A, Nonaka M, Hisamoto H, Uchiyama K, Kikutani Y, Tokeshi M, Kitamori T (2002) Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels. Anal Chem 74:1724-1728
    • (2002) Anal Chem , vol.74 , pp. 1724-1728
    • Hibara, A.1    Nonaka, M.2    Hisamoto, H.3    Uchiyama, K.4    Kikutani, Y.5    Tokeshi, M.6    Kitamori, T.7
  • 10
    • 0035866679 scopus 로고    scopus 로고
    • On-chip integration of neutral ionophore-based ion pair extraction reaction
    • Hisamoto H, Horiuchi T, Tokeshi M, Hibara A, Kitamori T (2001) On-chip integration of neutral ionophore-based ion pair extraction reaction. Anal Chem 73:1382-1386
    • (2001) Anal Chem , vol.73 , pp. 1382-1386
    • Hisamoto, H.1    Horiuchi, T.2    Tokeshi, M.3    Hibara, A.4    Kitamori, T.5
  • 11
    • 0037108778 scopus 로고    scopus 로고
    • Selective ion extraction: A separation method for microfluidic devices
    • DOI 10.1021/ac0258103
    • Kerby MB, Spaid M, Wu S, Parce JW, Chien RL (2002) Selective ion extraction: a separation method for microfluidic devices. Anal Chem 74:5175-5183 (Pubitemid 35215345)
    • (2002) Analytical Chemistry , vol.74 , Issue.20 , pp. 5175-5183
    • Kerby, M.B.1    Spaid, M.2    Wu, S.3    Parce, J.W.4    Chien, R.-L.5
  • 14
    • 70349795444 scopus 로고    scopus 로고
    • Optimization of some experimental parameters in the electro membrane extraction of chlorophenols from seawater
    • Lee J, Khalilian F, Bagheri H, Lee HK (2009) Optimization of some experimental parameters in the electro membrane extraction of chlorophenols from seawater. J Chromatogr A 1216:7687-7693
    • (2009) J Chromatogr A , vol.1216 , pp. 7687-7693
    • Lee, J.1    Khalilian, F.2    Bagheri, H.3    Lee, H.K.4
  • 15
    • 4143088056 scopus 로고    scopus 로고
    • Liquid membrane operations in a microfluidic device for selective separation of metal ions
    • Maruyama T, Matsushita H, Uchida J, Kubota F, Kamiya N, Goto M (2004) Liquid membrane operations in a microfluidic device for selective separation of metal ions. Anal Chem 76:4495-4500
    • (2004) Anal Chem , vol.76 , pp. 4495-4500
    • Maruyama, T.1    Matsushita, H.2    Uchida, J.3    Kubota, F.4    Kamiya, N.5    Goto, M.6
  • 16
    • 42349092875 scopus 로고    scopus 로고
    • Microfluidic droplet-based liquid-liquid extraction
    • Mary P, Studer V, Tabeling P (2008) Microfluidic droplet-based liquid-liquid extraction. Anal Chem 80:2680-2687
    • (2008) Anal Chem , vol.80 , pp. 2680-2687
    • Mary, P.1    Studer, V.2    Tabeling, P.3
  • 18
    • 0141886229 scopus 로고    scopus 로고
    • Integration of a wet analysis system on a glass chip: Determination of Co(II) as 2-nitroso-1-naphthol chelates by solvent extraction and thermal lens microscopy
    • Minagawa T, Tokeshi M, Kitamori T (2001) Integration of a wet analysis system on a glass chip: determination of Co(II) as 2-nitroso-1-naphthol chelates by solvent extraction and thermal lens microscopy. Lab Chip 1:72-75
    • (2001) Lab Chip , vol.1 , pp. 72-75
    • Minagawa, T.1    Tokeshi, M.2    Kitamori, T.3
  • 19
    • 33644830798 scopus 로고    scopus 로고
    • Electrokinetic migration across artificial liquid membranes-new concept for rapid sample preparation of biological fluids
    • Pedersen-Bjergaard S, Rasmussen KE (2006) Electrokinetic migration across artificial liquid membranes-new concept for rapid sample preparation of biological fluids. J Chromatogr A 1109:183-190
    • (2006) J Chromatogr A , vol.1109 , pp. 183-190
    • Pedersen-Bjergaard, S.1    Rasmussen, K.E.2
  • 20
    • 34248182961 scopus 로고    scopus 로고
    • Extraction across supported liquid membranes by use of electrical fields
    • Pedersen-Bjergaard S, Rasmussen KE (2007) Extraction across supported liquid membranes by use of electrical fields. Anal Bioanal Chem 388:521-523
    • (2007) Anal Bioanal Chem , vol.388 , pp. 521-523
    • Pedersen-Bjergaard, S.1    Rasmussen, K.E.2
  • 21
    • 59049095858 scopus 로고    scopus 로고
    • Drop-to-drop microextraction across a supported liquid membrane by an electrical field under stagnant conditions
    • Petersen NJ, Jensen H, Hansen SH, Rasmussen KE, Pedersen- Bjergaard S (2009) Drop-to-drop microextraction across a supported liquid membrane by an electrical field under stagnant conditions. J Chromatogr A 1216:1496-1502
    • (2009) J Chromatogr A , vol.1216 , pp. 1496-1502
    • Petersen, N.J.1    Jensen, H.2    Hansen, S.H.3    Rasmussen, K.E.4    Pedersen-Bjergaard, S.5
  • 22
    • 0346687607 scopus 로고    scopus 로고
    • Developments in hollow fibre-based, liquid-phase microextraction
    • Rasmussen KE, Pedersen-Biergaard S (2004) Developments in hollow fibre-based, liquid-phase microextraction. Trac-Trends Anal Chem 23:1-10
    • (2004) Trac-Trends Anal Chem , vol.23 , pp. 1-10
    • Rasmussen, K.E.1    Pedersen-Biergaard, S.2
  • 23
    • 51649104860 scopus 로고    scopus 로고
    • Improved microfluidic chip-based sequentialinjection trapped-droplet array liquid-liquid extraction system for determination of aluminium
    • Shen H, Fang Q (2008) Improved microfluidic chip-based sequentialinjection trapped-droplet array liquid-liquid extraction system for determination of aluminium. Talanta 77:269-272
    • (2008) Talanta , vol.77 , pp. 269-272
    • Shen, H.1    Fang, Q.2
  • 24
    • 33751014520 scopus 로고    scopus 로고
    • A microfluidic chip based sequential injection system with trapped droplet liquid-liquid extraction and chemiluminescence detection
    • Shen H, Fang Q, Fang ZL (2006) A microfluidic chip based sequential injection system with trapped droplet liquid-liquid extraction and chemiluminescence detection. Lab Chip 6:1387-1389
    • (2006) Lab Chip , vol.6 , pp. 1387-1389
    • Shen, H.1    Fang, Q.2    Fang, Z.L.3
  • 25
    • 0036558169 scopus 로고    scopus 로고
    • Three-layer flow membrane system on a microchip for investigation of molecular transport
    • Surmeian M, Slyadnev MN, Hisamoto H, Hibara A, Uchiyama K, Kitamori T (2002) Three-layer flow membrane system on a microchip for investigation of molecular transport. Anal Chem 74:2014-2020
    • (2002) Anal Chem , vol.74 , pp. 2014-2020
    • Surmeian, M.1    Slyadnev, M.N.2    Hisamoto, H.3    Hibara, A.4    Uchiyama, K.5    Kitamori, T.6
  • 27
    • 0034644857 scopus 로고    scopus 로고
    • Integration of a microextraction system-solvent extraction of a Co-2-nitroso-5- dimethylaminophenol complex on a microchip
    • Tokeshi M, Minagawa T, Kitamori T (2000a) Integration of a microextraction system-solvent extraction of a Co-2-nitroso-5- dimethylaminophenol complex on a microchip. J Chromatogr A 894:19-23
    • (2000) J Chromatogr A , vol.894 , pp. 19-23
    • Tokeshi, M.1    Minagawa, T.2    Kitamori, T.3
  • 28
    • 0034079719 scopus 로고    scopus 로고
    • Integration of a microextraction system on a glass chip: Ion-pair solvent extraction of Fe(II) with 4, 7-diphenyl-1, 10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride
    • Tokeshi M, Minagawa T, Kitamori T (2000b) Integration of a microextraction system on a glass chip: Ion-pair solvent extraction of Fe(II) with 4, 7-diphenyl-1, 10-phenanthrolinedisulfonic acid and tri-n- octylmethylammonium chloride. Anal Chem 72:1711-1714
    • (2000) Anal Chem , vol.72 , pp. 1711-1714
    • Tokeshi, M.1    Minagawa, T.2    Kitamori, T.3
  • 29
    • 0036534976 scopus 로고    scopus 로고
    • Continuous-flow chemical processing on a microchip by combining microunit operations and a multiphase flow network
    • Tokeshi M, Minagawa T, Uchiyama K, Hibara A, Sato K, Hisamoto H, Kitamori T (2002) Continuous-flow chemical processing on a microchip by combining microunit operations and a multiphase flow network. Anal Chem 74:1565-1571
    • (2002) Anal Chem , vol.74 , pp. 1565-1571
    • Tokeshi, M.1    Minagawa, T.2    Uchiyama, K.3    Hibara, A.4    Sato, K.5    Hisamoto, H.6    Kitamori, T.7
  • 30
    • 33746562277 scopus 로고    scopus 로고
    • Initial study of two-phase laminar flow extraction chip for sample preparation for gas chromatography
    • Xiao H, Liang D, Liu GC, Guo M, Xing WL, Cheng J (2006) Initial study of two-phase laminar flow extraction chip for sample preparation for gas chromatography. Lab Chip 6:1067-1072
    • (2006) Lab Chip , vol.6 , pp. 1067-1072
    • Xiao, H.1    Liang, D.2    Liu, G.C.3    Guo, M.4    Xing, W.L.5    Cheng, J.6
  • 31
    • 56549118452 scopus 로고    scopus 로고
    • Electro membrane isolation of nerve agent degradation products across a supported liquid membrane followed by capillary electrophoresis with contactless conductivity detection
    • Xu L, Hauser PC, Lee HK (2008) Electro membrane isolation of nerve agent degradation products across a supported liquid membrane followed by capillary electrophoresis with contactless conductivity detection. J Chromatogr A 1214:17-22
    • (2008) J Chromatogr A , vol.1214 , pp. 17-22
    • Xu, L.1    Hauser, P.C.2    Lee, H.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.