메뉴 건너뛰기




Volumn 31, Issue 7, 2010, Pages 1107-1110

Secondary residual shunt after atrial septal defect closure with an amplatzer occluder: Surgical removal and evaluation of device biocompatibility after 7 years

Author keywords

Amplatzer occluder; Atrial septal defect; Biocompatibility

Indexed keywords

ARTICLE; BIOCOMPATIBILITY; CASE REPORT; CHILD; CORROSION; DEVICE; DEVICE REMOVAL; FOLLOW UP; HEART ATRIUM SEPTUM DEFECT; HUMAN; IMMUNE RESPONSE; IN VIVO STUDY; MALE;

EID: 77957596290     PISSN: 01720643     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00246-010-9757-y     Document Type: Article
Times cited : (4)

References (11)
  • 1
    • 64349098418 scopus 로고    scopus 로고
    • A new pan-nitinol occluder for transcatheter closure of ventricular septal defects in a canine model
    • 10.1111/j.1540-8183.2009.00432.x
    • ZR Ding YW Qin JQ Hu, et al. 2009 A new pan-nitinol occluder for transcatheter closure of ventricular septal defects in a canine model Interv Cardiol 22 191 198 10.1111/j.1540-8183.2009.00432.x
    • (2009) Interv Cardiol , vol.22 , pp. 191-198
    • Ding, Z.R.1    Qin, Y.W.2    Hu, J.Q.3
  • 2
    • 0037024255 scopus 로고    scopus 로고
    • Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: Results of a multicenter nonrandomized trial
    • DOI 10.1016/S0735-1097(02)01862-4, PII S0735109702018624
    • ZD Du ZM Hijazi CS Kleinman NH Silverman K Larntz Amplatzer Investigators 2002 Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: Results of a multicenter nonrandomized trial Am Coll Cardiol 39 1836 1844 10.1016/S0735-1097(02)01862-4 (Pubitemid 34595297)
    • (2002) Journal of the American College of Cardiology , vol.39 , Issue.11 , pp. 1836-1844
    • Du, Z.-D.1    Hijazi, Z.M.2    Kleinman, C.S.3    Silverman, N.H.4    Larntz, K.5
  • 3
    • 0036582427 scopus 로고    scopus 로고
    • Corrosive behaviour of Amplatzer® devices in experimental and biological environments
    • DOI 10.1017/S1047951102000562
    • H Kong JL Wilkinson JY Coe, et al. 2002 Corrosive behaviour of Amplatzer devices in experimental and biological environments Cardiol Young 12 260 265 10.1017/S1047951102000562 12365173 (Pubitemid 41238840)
    • (2002) Cardiology in the Young , vol.12 , Issue.3 , pp. 260-265
    • Kong, H.1    Wilkinson, J.L.2    Coe, J.Y.3    Gu, X.4    Urness, M.5    Kim, T.-H.6    Bass, J.L.7
  • 4
    • 0031467061 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: Initial human experience
    • DOI 10.1002/(SICI)1097-0304(199712)42:4<388::AID-CCD7>3.0.CO;2-7
    • J Masura P Gavora A Formanek ZM Hijazi 1997 Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer septal occluder: Initial human experience Cathet Cardiovasc Diagn 42 388 393 1:STN:280:DyaK1c%2Fnt12itw%3D%3D 10.1002/(SICI)1097-0304(199712)42:4<388:: AID-CCD7>3.0.CO;2-7 9408617 (Pubitemid 28006346)
    • (1997) Catheterization and Cardiovascular Diagnosis , vol.42 , Issue.4 , pp. 388-394
    • Masura, J.1    Gavora, P.2    Formanek, A.3    Hijazi, Z.M.4
  • 5
    • 13544253485 scopus 로고    scopus 로고
    • Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders
    • DOI 10.1016/j.jacc.2004.10.066
    • J Masura P Gavora T Podnar 2005 Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders J Am Coll Cardiol 45 505 507 10.1016/j.jacc.2004.10.066 15708695 (Pubitemid 40222242)
    • (2005) Journal of the American College of Cardiology , vol.45 , Issue.4 , pp. 505-507
    • Masura, J.1    Gavora, P.2    Podnar, T.3
  • 6
    • 0035100073 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects in children and adults using the Amplatzer septal occluder
    • 1:STN:280:DC%2BD38zht1SjtA%3D%3D 10.1111/j.1540-8183.2001.tb00709.x
    • A Omeish ZM Hijazi 2001 Transcatheter closure of atrial septal defects in children and adults using the Amplatzer septal occluder Interv Cardiol 14 37 44 1:STN:280:DC%2BD38zht1SjtA%3D%3D 10.1111/j.1540-8183.2001.tb00709.x
    • (2001) Interv Cardiol , vol.14 , pp. 37-44
    • Omeish, A.1    Hijazi, Z.M.2
  • 7
    • 0030995970 scopus 로고    scopus 로고
    • Transvenous closure of secundum atrial septal defects: Preliminary results with a new self-expanding nitinol prosthesis in a swine model
    • 1:STN:280:DyaK2s3nvV2msg%3D%3D 9133527
    • MJ Sharafuddin X Gu JL Titus, et al. 1997 Transvenous closure of secundum atrial septal defects: preliminary results with a new self-expanding nitinol prosthesis in a swine model Circulation 95 2162 2168 1:STN:280: DyaK2s3nvV2msg%3D%3D 9133527
    • (1997) Circulation , vol.95 , pp. 2162-2168
    • Sharafuddin, M.J.1    Gu, X.2    Titus, J.L.3
  • 8
    • 34247343186 scopus 로고    scopus 로고
    • Biocompatibility of septal defect closure devices
    • DOI 10.1136/hrt.2006.098103
    • M Sigler C Jux 2007 Biocompatibility of septal defect closure devices Heart 93 444 449 10.1136/hrt.2006.098103 17035510 (Pubitemid 46631507)
    • (2007) Heart , vol.93 , Issue.4 , pp. 444-449
    • Sigler, M.1    Jux, C.2
  • 9
    • 21544469971 scopus 로고    scopus 로고
    • Biocompatibility screening in cardiovascular implants
    • DOI 10.1007/s00392-005-0231-4
    • M Sigler T Paul RG Grabitz 2005 Biocompatibility screening in cardiovascular implants Z Kardiol 94 383 391 1:CAS:528:DC%2BD2MXmsFSjsL4%3D 10.1007/s00392-005-0231-4 15940438 (Pubitemid 40921966)
    • (2005) Zeitschrift fur Kardiologie , vol.94 , Issue.6 , pp. 383-391
    • Sigler, M.1    Paul, T.2    Grabitz, R.G.3
  • 10
    • 33845494071 scopus 로고    scopus 로고
    • Histopathological workup of an Amplatzer atrial septal defect occluder after surgical removal
    • DOI 10.1007/s00246-006-1413-1
    • M Sigler C Jux P Ewert 2006 Histopathological workup of an Amplatzer atrial septal defect occluder after surgical removal Pediatr Cardiol 27 775 776 10.1007/s00246-006-1413-1 17031717 (Pubitemid 44915421)
    • (2006) Pediatric Cardiology , vol.27 , Issue.6 , pp. 775-776
    • Sigler, M.1    Jux, C.2    Ewert, P.3
  • 11
    • 0036163685 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects using Amplatzer septal occluder
    • K Xiangqing C Kejiang Y Rong, et al. 2002 Transcatheter closure of secundum atrial septal defects using Amplatzer septal occluder Chin Med 115 126 128
    • (2002) Chin Med , vol.115 , pp. 126-128
    • Xiangqing, K.1    Kejiang, C.2    Rong, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.