메뉴 건너뛰기




Volumn 49, Issue 28, 2010, Pages 5302-5308

Off-axis cavity enhanced spectroscopy based on a pulsed quantum cascade laser for sensitive detection of ammonia and ethylene

Author keywords

[No Author keywords available]

Indexed keywords

ABSORPTION SPECTROSCOPY; AMMONIA; ETHYLENE; QUANTUM CASCADE LASERS; SIGNAL TO NOISE RATIO;

EID: 77957594377     PISSN: 1559128X     EISSN: 15394522     Source Type: Journal    
DOI: 10.1364/AO.49.005302     Document Type: Article
Times cited : (11)

References (25)
  • 1
    • 0028304539 scopus 로고
    • Quantum cascade laser
    • J. Faist and F. Capasso, "Quantum cascade laser," Science 264, 553-556 (1994).
    • (1994) Science , vol.264 , pp. 553-556
    • Faist, J.1    Capasso, F.2
  • 3
    • 2342584132 scopus 로고    scopus 로고
    • Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection
    • Y. A. Bakhirkin, A. A. Kosterev, C. Roller, R. F. Curl, and F. K. Tittel, "Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection," Appl. Opt. 43, 2257-2266 (2004).
    • (2004) Appl. Opt. , vol.43 , pp. 2257-2266
    • Bakhirkin, Y.A.1    Kosterev, A.A.2    Roller, C.3    Curl, R.F.4    Tittel, F.K.5
  • 4
    • 0036450204 scopus 로고    scopus 로고
    • Highly sensitive detection of trace gases using pulsed quantum cascade lasers
    • G. Duxbury, E. L. Normand, N. Langford, M. T. McCulloch, and S.Walker, "Highly sensitive detection of trace gases using pulsed quantum cascade lasers," Proc. SPSPIE 4817, 14-21 (2002).
    • (2002) Proc. SPIE , vol.4817 , pp. 14-21
    • Duxbury, G.1    Normand, E.L.2    Langford, N.3    McCulloch, M.T.4    Walker, S.5
  • 7
    • 0037137769 scopus 로고    scopus 로고
    • Transportable automated ammonia sensor based on a pulsed thermoelectrically cooled quantum-cascade distributed feedback laser
    • A. A. Kosterev, R. F. Curl, F. K. Tittel, R. Kohler, C. Gmachl, F. Capasso, D. L. Sivco, and A. Y. Cho, "Transportable automated ammonia sensor based on a pulsed thermoelectrically cooled quantum-cascade distributed feedback laser," Appl. Opt. 41, 573-578 (2002).
    • (2002) Appl. Opt. , vol.41 , pp. 573-578
    • Kosterev, A.A.1    Curl, R.F.2    Tittel, F.K.3    Kohler, R.4    Gmachl, C.5    Capasso, F.6    Sivco, D.L.7    Cho, A.Y.8
  • 12
    • 0032000454 scopus 로고    scopus 로고
    • Sensitive absorption spectroscopy with a room-temperature distributed-feedback quantum-cascade laser
    • K. Namjou, S. Cai, E. A. Whittaker, J. Faist, C. Gmachl, F. Capasso, D. L. Sivco, and A. Y. Cho, "Sensitive absorption spectroscopy with a room-temperature distributed-feedback quantum-cascade laser," Opt. Lett. 23, 219-221 (1998).
    • (1998) Opt. Lett. , vol.23 , pp. 219-221
    • Namjou, K.1    Cai, S.2    Whittaker, E.A.3    Faist, J.4    Gmachl, C.5    Capasso, F.6    Sivco, D.L.7    Cho, A.Y.8
  • 13
    • 9644255705 scopus 로고    scopus 로고
    • High precision measurements of atmospheric nitrous oxide and methane using thermoelectrically cooled mid-infrared quantum cascade lasers and detectors
    • D. D. Nelson, B. McManus, S. Urbanski, S. Herndon, and M. S. Zahniser, "High precision measurements of atmospheric nitrous oxide and methane using thermoelectrically cooled mid-infrared quantum cascade lasers and detectors," Spectrochim. Acta, Part A, Mol. Spectrosc. 60, 3325-3335 (2004).
    • (2004) Spectrochim. Acta, Part A, Mol. Spectrosc. , vol.60 , pp. 3325-3335
    • Nelson, D.D.1    McManus, B.2    Urbanski, S.3    Herndon, S.4    Zahniser, M.S.5
  • 14
    • 25144505892 scopus 로고    scopus 로고
    • Integrated cavity output spectroscopy measurements of NO levels in breath with a pulsed room-temperature QCL
    • M. L. Silva, D. M. Sonnenfroh, D. I. Rosen, M. G. Allen, and A. O'Keefe, "Integrated cavity output spectroscopy measurements of NO levels in breath with a pulsed room-temperature QCL," Appl. Phys. B 81, 705-710 (2005).
    • (2005) Appl. Phys. B , vol.81 , pp. 705-710
    • Silva, M.L.1    Sonnenfroh, D.M.2    Rosen, D.I.3    Allen, M.G.4    O'keefe, A.5
  • 15
    • 33646735765 scopus 로고    scopus 로고
    • Cavity ringdown spectroscopy with a pulsed distributed feedback quantum cascade laser
    • O. Sukhorukov, A. Lytkine, J. Manne, J. Tulip, and W. Jager, "Cavity ringdown spectroscopy with a pulsed distributed feedback quantum cascade laser," Proc. SPIE 6127, 61270A (2006).
    • (2006) Proc. SPIE , vol.6127
    • Sukhorukov, O.1    Lytkine, A.2    Manne, J.3    Tulip, J.4    Jager, W.5
  • 16
    • 33846885425 scopus 로고    scopus 로고
    • Pulsed quantum cascade laser-based cavity ringdown spectroscopy for ammonia detection in breath
    • J. Manne, O. Sukhorukov, W. Jager, and J. Tulip, "Pulsed quantum cascade laser-based cavity ringdown spectroscopy for ammonia detection in breath," Appl. Opt. 45, 9230-9237 (2006).
    • (2006) Appl. Opt. , vol.45 , pp. 9230-9237
    • Manne, J.1    Sukhorukov, O.2    Jager, W.3    Tulip, J.4
  • 18
    • 0000899797 scopus 로고    scopus 로고
    • Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy
    • R. Engeln, G. Berden, R. Peeters, and G. Meijer, "Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy," Rev. Sci. Instrum. 69, 3763-3769 (1998).
    • (1998) Rev. Sci. Instrum. , vol.69 , pp. 3763-3769
    • Engeln, R.1    Berden, G.2    Peeters, R.3    Meijer, G.4
  • 19
    • 0000735887 scopus 로고    scopus 로고
    • Integrated cavity output analysis of ultra-weak absorption
    • A. O'Keefe, "Integrated cavity output analysis of ultra-weak absorption," Chem. Phys. Lett. 293, 331-336 (1998).
    • (1998) Chem. Phys. Lett. , vol.293 , pp. 331-336
    • O'keefe, A.1
  • 21
    • 0035836626 scopus 로고    scopus 로고
    • Correlation of breath ammonia with blood urea nitrogen and creatinine during haemodialysis
    • L. R. Narasimhan, W. Goodman, and C. K. N. Patel, "Correlation of breath ammonia with blood urea nitrogen and creatinine during haemodialysis," Proc. Natl. Acad. Sci. U.S.A. 98, 4617-4621 (2001).
    • (2001) Proc. Natl. Acad. Sci. U.S.A. , vol.98 , pp. 4617-4621
    • Narasimhan, L.R.1    Goodman, W.2    Patel, C.K.N.3
  • 22
    • 31644433440 scopus 로고    scopus 로고
    • An historical overview of cavity-enhanced methods
    • B. A. Paldus and A. A. Kachanov, "An historical overview of cavity-enhanced methods," Can. J. Phys. 83, 975-999 (2005).
    • (2005) Can. J. Phys. , vol.83 , pp. 975-999
    • Paldus, B.A.1    Kachanov, A.A.2
  • 24
    • 0036610430 scopus 로고    scopus 로고
    • Chemical sensors based on quantum cascade lasers
    • A. A. Kosterev and F. K. Tittel, "Chemical sensors based on quantum cascade lasers," IEEE J. Quantum Electron. 38, 582-591 (2002).
    • (2002) IEEE J. Quantum Electron. , vol.38 , pp. 582-591
    • Kosterev, A.A.1    Tittel, F.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.