메뉴 건너뛰기




Volumn 46, Issue 10, 2010, Pages 2042-2050

Response mechanism of novel polyaniline composite conductimetric pH sensors and the effects of polymer binder, surfactant and film thickness on sensor sensitivity

Author keywords

Conductimetric; Conducting polymers; pH; Sensor; Thick films

Indexed keywords

COLE-COLE MODELS; CONDUCTIMETRIC; ELECTRICAL CHARACTERISTIC; FOCUSSED ION BEAM MILLINGS; IMPEDANCE SPECTROSCOPY; NITROGEN ATOM; POLYANILINE COMPOSITES; POLYMER BACKBONES; POLYMER BINDERS; RESPONSE MECHANISMS; SENSING CHARACTERISTICS; SENSING LAYERS; SENSOR RESPONSE; SENSOR SENSITIVITY;

EID: 77957374323     PISSN: 00143057     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.eurpolymj.2010.07.012     Document Type: Article
Times cited : (16)

References (21)
  • 4
    • 1342304795 scopus 로고    scopus 로고
    • A conductimetric humidity sensor based on proton conducting perovskite oxides
    • W. Wang, and A.V. Virkar A conductimetric humidity sensor based on proton conducting perovskite oxides Sens Actuators B: Chem 98 2004 282 290
    • (2004) Sens Actuators B: Chem , vol.98 , pp. 282-290
    • Wang, W.1    Virkar, A.V.2
  • 5
    • 0033991965 scopus 로고    scopus 로고
    • Sol-gel-derived thick-film conductometric biosensor for urea determination in serum
    • W.-Y. Lee, S.-R. Kim, T.-H. Kim, K.S. Lee, M.-C. Shin, and J.-K. Park Sol-gel-derived thick-film conductometric biosensor for urea determination in serum Anal Chim Acta 404 2000 195 203
    • (2000) Anal Chim Acta , vol.404 , pp. 195-203
    • Lee, W.-Y.1    Kim, S.-R.2    Kim, T.-H.3    Lee, K.S.4    Shin, M.-C.5    Park, J.-K.6
  • 6
    • 0033978399 scopus 로고    scopus 로고
    • A membrane-moderated conductimetric sensor for the detection and measurement of specific organic solutes in aqueous solutions
    • F.H. Arnold, W. Zheng, and A.S. Michaels A membrane-moderated conductimetric sensor for the detection and measurement of specific organic solutes in aqueous solutions J Membr Sci 167 2000 227 239
    • (2000) J Membr Sci , vol.167 , pp. 227-239
    • Arnold, F.H.1    Zheng, W.2    Michaels, A.S.3
  • 9
    • 5244321746 scopus 로고
    • The potential difference between glass and electrolytes in contact with the glass
    • W.S. Hughes The potential difference between glass and electrolytes in contact with the glass J Am Chem Soc 44 1922 2860 2867
    • (1922) J Am Chem Soc , vol.44 , pp. 2860-2867
    • Hughes, W.S.1
  • 10
    • 0030723770 scopus 로고    scopus 로고
    • Potentiometric pH sensors based on chemically modified electrodes with electropolymerized metal-tetraaminophthalocyanine
    • T.-F. Kang, Z.-Y. Xie, H. Tang, G.-L. Shen, and R.-Q. Yu Potentiometric pH sensors based on chemically modified electrodes with electropolymerized metal-tetraaminophthalocyanine Talanta 45 1997 291 296
    • (1997) Talanta , vol.45 , pp. 291-296
    • Kang, T.-F.1    Xie, Z.-Y.2    Tang, H.3    Shen, G.-L.4    Yu, R.-Q.5
  • 12
    • 11144272702 scopus 로고    scopus 로고
    • PH sensor using nano electrodes in organic semiconductor. Engineering in medicine and biology society, 2004
    • Xiaoshan Z, Ahn CH. pH sensor using nano electrodes in organic semiconductor. Engineering in medicine and biology society, 2004. In: IEMBS '04. 26th annual international conference of the IEEE; 2004. p. 1968-71.
    • (2004) IEMBS '04. 26th Annual International Conference of the IEEE , pp. 1968-1971
    • Xiaoshan, Z.1    Ahn, C.H.2
  • 13
    • 39749091675 scopus 로고    scopus 로고
    • PH sensitivity of novel PANI/PVB/PS3 composite films
    • E. Gill, A. Arshak, K. Arshak, and O. Korostynska pH sensitivity of novel PANI/PVB/PS3 composite films Sens J 7 2007 3329 3346
    • (2007) Sens J , vol.7 , pp. 3329-3346
    • Gill, E.1    Arshak, A.2    Arshak, K.3    Korostynska, O.4
  • 15
    • 85008039160 scopus 로고    scopus 로고
    • Investigation of thick film polyaniline-based conductimetric pH sensors for medical applications
    • E. Gill, A. Arshak, K. Arshak, and O. Korostynska Investigation of thick film polyaniline-based conductimetric pH sensors for medical applications IEEE Sens J 9 2009 555 562
    • (2009) IEEE Sens J , vol.9 , pp. 555-562
    • Gill, E.1    Arshak, A.2    Arshak, K.3    Korostynska, O.4
  • 17
    • 0031104158 scopus 로고    scopus 로고
    • Conducting polymer based pH detector: A new outlook to pH sensing technology
    • A. Talaie Conducting polymer based pH detector: a new outlook to pH sensing technology Polymer 38 1997 1145 1150
    • (1997) Polymer , vol.38 , pp. 1145-1150
    • Talaie, A.1
  • 18
    • 0037047232 scopus 로고    scopus 로고
    • PH sensitivity of polyaniline and its substituted derivatives
    • T. Lindfors, and A. Ivaska pH sensitivity of polyaniline and its substituted derivatives J Electroanal Chem 531 2002 43 52
    • (2002) J Electroanal Chem , vol.531 , pp. 43-52
    • Lindfors, T.1    Ivaska, A.2
  • 20
    • 13444257815 scopus 로고    scopus 로고
    • Determination of the electrical behaviour of surfactant treated polymer/carbon black composite gas sensors
    • K. Arshak, E. Moore, L. Cavanagh, J. Harris, B. McConigly, and C. Cunniffe Determination of the electrical behaviour of surfactant treated polymer/carbon black composite gas sensors Compos Part A: Appl Sci Manuf 36 2005 487 491
    • (2005) Compos Part A: Appl Sci Manuf , vol.36 , pp. 487-491
    • Arshak, K.1    Moore, E.2    Cavanagh, L.3    Harris, J.4    McConigly, B.5    Cunniffe, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.