메뉴 건너뛰기




Volumn 52, Issue 4 SUPPL., 2010, Pages 50S-59S

Intraprocedural imaging: Flat panel detectors, rotational angiography, FluoroCT, IVUS, or still the portable C-arm?

Author keywords

[No Author keywords available]

Indexed keywords

CARDIAC RESYNCHRONIZATION THERAPY; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; DIAGNOSTIC IMAGING; FLUOROSCOPY; HUMAN; INTRAVASCULAR ULTRASOUND; MULTIDETECTOR COMPUTED TOMOGRAPHY; MYOCARDIAL PERFUSION IMAGING; PHOTOGRAPHY; PRIORITY JOURNAL; REVIEW; THREE DIMENSIONAL ECHOCARDIOGRAPHY; ANGIOGRAPHY; DEVICES; ENDOSCOPIC ECHOGRAPHY; IMAGE ENHANCEMENT; IMAGE PROCESSING; INTERVENTIONAL RADIOLOGY; PROCEDURES; STANDARDS; VASCULAR SURGERY;

EID: 77957370132     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvs.2010.06.144     Document Type: Editorial
Times cited : (17)

References (22)
  • 1
    • 8544226224 scopus 로고    scopus 로고
    • Flat-panel detectors in the cardiac catheterization laboratory: Revolution or evolution - What are the issues?
    • D. Holmes Jr, W. Laskey, M. Wondrow, and J. Cusma Flat-panel detectors in the cardiac catheterization laboratory: revolution or evolution - what are the issues? Catheter Cardiovasc Interv 63 2004 324 330
    • (2004) Catheter Cardiovasc Interv , vol.63 , pp. 324-330
    • Holmes, Jr.D.1    Laskey, W.2    Wondrow, M.3    Cusma, J.4
  • 2
    • 0029014292 scopus 로고
    • Automated and accurate assessment of the distribution, magnitude, and direction of pincusion distortion in angiographic images
    • P. van der Zwet, D. Meyer, and J. Reiber Automated and accurate assessment of the distribution, magnitude, and direction of pincusion distortion in angiographic images Invest Radiol 30 1995 204 213
    • (1995) Invest Radiol , vol.30 , pp. 204-213
    • Van Der Zwet, P.1    Meyer, D.2    Reiber, J.3
  • 3
    • 33746599563 scopus 로고    scopus 로고
    • Flat-panel detectors: How much better are they?
    • J. Seibert Flat-panel detectors: how much better are they? Pediatr Radiol 36 Supp 2 2006 173 181
    • (2006) Pediatr Radiol , vol.36 , Issue.SUPPL. 2 , pp. 173-181
    • Seibert, J.1
  • 4
    • 0035185721 scopus 로고    scopus 로고
    • Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems - A contrast detail phantom study
    • X. Rong, C. Shaw, X. Liu, M. Lemacks, and S. Thompson Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems - a contrast detail phantom study Med Phys 28 2001 2328 2335
    • (2001) Med Phys , vol.28 , pp. 2328-2335
    • Rong, X.1    Shaw, C.2    Liu, X.3    Lemacks, M.4    Thompson, S.5
  • 5
    • 0035119131 scopus 로고    scopus 로고
    • Imaging characteristics of an amorphous silicon flat-panel detector for digital chest imaging
    • C.J. Floyd, R. Warp, J. Dobbins 3, H. Chotas, A. Baydush, and R. Vargas-Voracek Imaging characteristics of an amorphous silicon flat-panel detector for digital chest imaging Radiology 218 2001 683 688
    • (2001) Radiology , vol.218 , pp. 683-688
    • Floyd, C.J.1    Warp, R.2    Chotas, H.3    Baydush, A.4    Vargas-Voracek, R.5
  • 6
    • 25644437912 scopus 로고    scopus 로고
    • Indirect flat panel detector with avalanche gain: Fundamental feasibility investigtion for SHARP-AMFPI (scintillator HARP active matrix flat panel imager)
    • W. Zhao, D. Li, A. Reznik, B. Lui, D. Hunt, and J. Rowlands Indirect flat panel detector with avalanche gain: fundamental feasibility investigtion for SHARP-AMFPI (scintillator HARP active matrix flat panel imager) Med Phys 32 2005 2954 2966
    • (2005) Med Phys , vol.32 , pp. 2954-2966
    • Zhao, W.1    Li, D.2    Reznik, A.3    Lui, B.4    Hunt, D.5    Rowlands, J.6
  • 8
    • 42449142411 scopus 로고    scopus 로고
    • DynaCT soft-tissue visualization using an angiographic C-arm system: Initial clinical experience in the operating room
    • K. Irie, Y. Murayama, T. Saguchi, T. Ishibashi, M. Ebara, and H. Takao DynaCT soft-tissue visualization using an angiographic C-arm system: initial clinical experience in the operating room Oper Neurosurg 62 2007 266 272
    • (2007) Oper Neurosurg , vol.62 , pp. 266-272
    • Irie, K.1    Murayama, Y.2    Saguchi, T.3    Ishibashi, T.4    Ebara, M.5    Takao, H.6
  • 9
    • 0036328179 scopus 로고    scopus 로고
    • Current technology and clinical applications of three-dimensional angiography
    • R. Klucznik Current technology and clinical applications of three-dimensional angiography Radiol Clin North Am 40 2002 711 728
    • (2002) Radiol Clin North Am , vol.40 , pp. 711-728
    • Klucznik, R.1
  • 10
    • 57049090112 scopus 로고    scopus 로고
    • Evaluation of the quality of CT-like images obtained during a commercial flat panel detector system
    • J. Smyth, D. Sutton, and J. Huston Evaluation of the quality of CT-like images obtained during a commercial flat panel detector system Biomed Imagin Interv J 2 2006 e48
    • (2006) Biomed Imagin Interv J , vol.2 , pp. 48
    • Smyth, J.1    Sutton, D.2    Huston, J.3
  • 11
    • 56049106562 scopus 로고    scopus 로고
    • Intra-operative dynaCT in visceral-hybrid repair of an extensive thoracoabdominal aortic aneurysm
    • L. Biasi, T. Ali, and M. Thompson Intra-operative dynaCT in visceral-hybrid repair of an extensive thoracoabdominal aortic aneurysm Eur J Cardiothorac Surg 34 2008 1251 1252
    • (2008) Eur J Cardiothorac Surg , vol.34 , pp. 1251-1252
    • Biasi, L.1    Ali, T.2    Thompson, M.3
  • 12
    • 0036694867 scopus 로고    scopus 로고
    • Virtual angioscopy using 3-dimensional rotational digital subtraction angiography for endovascular assessment
    • N. Unno, H. Mitsuoka, Y. Takei, T. Igarashi, T. Uchiyama, and N. Yamamoto Virtual angioscopy using 3-dimensional rotational digital subtraction angiography for endovascular assessment J Endovasc Ther 9 2002 529 534
    • (2002) J Endovasc Ther , vol.9 , pp. 529-534
    • Unno, N.1    Mitsuoka, H.2    Takei, Y.3    Igarashi, T.4    Uchiyama, T.5    Yamamoto, N.6
  • 13
    • 0036136287 scopus 로고    scopus 로고
    • Using three-dimensional rotational angiography for sizing of covered stents
    • J. van den Berg, T. Overtoom, J. de Valois, and F. Moll Using three-dimensional rotational angiography for sizing of covered stents Am J Radiol 178 2002 149 152
    • (2002) Am J Radiol , vol.178 , pp. 149-152
    • Van Den Berg, J.1    Overtoom, T.2    De Valois, J.3    Moll, F.4
  • 14
    • 0141478967 scopus 로고    scopus 로고
    • Three-dimensional rotational angiograph in peripheral endovascular interventions
    • J. van den Berg, and F. Moll Three-dimensional rotational angiograph in peripheral endovascular interventions J Endovasc Ther 10 2003 595 600
    • (2003) J Endovasc Ther , vol.10 , pp. 595-600
    • Van Den Berg, J.1    Moll, F.2
  • 15
    • 67349110849 scopus 로고    scopus 로고
    • Intraoperative DynaCT detection and immediate correction of a Type 1a endoleak following endovascular repair of abdominal aortic aneurysm
    • L. Biasi, T. Ali, R. Hinchcliffe, and R. Morgan Intraoperative DynaCT detection and immediate correction of a Type 1a endoleak following endovascular repair of abdominal aortic aneurysm Cardiovasc Intervent Radiol 32 2009 535 538
    • (2009) Cardiovasc Intervent Radiol , vol.32 , pp. 535-538
    • Biasi, L.1    Ali, T.2    Hinchcliffe, R.3    Morgan, R.4
  • 16
    • 71049141662 scopus 로고    scopus 로고
    • Accuracy and usefulness of fusion imaging between three-dimensional coronary sinus and coronary veins computed tomographic images with projection images obtained using fluoroscopy
    • A. Auricchio, A. Sorgent, E. Soubelet, F. Regoli, G. Spinucci, and R. Vaillant Accuracy and usefulness of fusion imaging between three-dimensional coronary sinus and coronary veins computed tomographic images with projection images obtained using fluoroscopy Europace 11 2009 1483 1490
    • (2009) Europace , vol.11 , pp. 1483-1490
    • Auricchio, A.1    Sorgent, A.2    Soubelet, E.3    Regoli, F.4    Spinucci, G.5    Vaillant, R.6
  • 17
    • 48749130258 scopus 로고    scopus 로고
    • Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia
    • S. Knecht, H. Skali, M. O'Neill, M. Wright, S. Matsuo, and G. Chaudhry Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia Europace 10 2008 931 938
    • (2008) Europace , vol.10 , pp. 931-938
    • Knecht, S.1    Skali, H.2    O'Neill, M.3    Wright, M.4    Matsuo, S.5    Chaudhry, G.6
  • 18
    • 33748688200 scopus 로고    scopus 로고
    • Intravascular ultrasound use in the treatment of thoracoabdominal dissections, aneurysms, and transections
    • T. Song, C. Donayre, G. Kopchok, and R. White Intravascular ultrasound use in the treatment of thoracoabdominal dissections, aneurysms, and transections Semin Vasc Surg 19 2006 145 149
    • (2006) Semin Vasc Surg , vol.19 , pp. 145-149
    • Song, T.1    Donayre, C.2    Kopchok, G.3    White, R.4
  • 19
    • 52049117889 scopus 로고    scopus 로고
    • Intravascular ultrasound imaging as applied to the aorta: A new tool for the cardiovascular surgeon
    • J. Kpodonu, V. Ramaiah, and E. Dietrich Intravascular ultrasound imaging as applied to the aorta: a new tool for the cardiovascular surgeon Ann Thorac Surg 86 2008 1391 1398
    • (2008) Ann Thorac Surg , vol.86 , pp. 1391-1398
    • Kpodonu, J.1    Ramaiah, V.2    Dietrich, E.3
  • 20
    • 44949175946 scopus 로고    scopus 로고
    • The future of imaging in the management of abdominal aortic aneurysm
    • R. Nyman, and M. Eriksson The future of imaging in the management of abdominal aortic aneurysm Scand J Su 97 2008 110 115
    • (2008) Scand J Su , vol.97 , pp. 110-115
    • Nyman, R.1    Eriksson, M.2
  • 22
    • 70350007038 scopus 로고    scopus 로고
    • Intravascular ultrasound with a vector phased-array probe (AcuNav) is feasible in endovascular abdominal aortic aneurysm repair
    • M.-O. Eriksson, A. Wanhainen, and R. Nyman Intravascular ultrasound with a vector phased-array probe (AcuNav) is feasible in endovascular abdominal aortic aneurysm repair Acta Radiol 8 2009 870 875
    • (2009) Acta Radiol , vol.8 , pp. 870-875
    • Eriksson, M.-O.1    Wanhainen, A.2    Nyman, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.