메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Do hipot tests damage rotating machine insulation?

Author keywords

Damage; Hipot test; Insulation; Rotating machine

Indexed keywords

ACCEPTANCE TESTS; DAMAGE; ELECTRICAL INSULATION; HIPOT TEST; INDUSTRY EXPERTS; INSULATION SYSTEM; LITERATURE REVIEWS; PLANT MANAGERS; ROTATING MACHINE; ROTATING MACHINE INSULATION; STATOR COIL;

EID: 77957355117     PISSN: 01642006     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ELINSL.2010.5549759     Document Type: Conference Paper
Times cited : (2)

References (14)
  • 6
    • 70449652305 scopus 로고    scopus 로고
    • Stator winding hipot (High Potential) testing
    • Montreal, QC, May 31-June 3, 2009, IEEE Publication CFP09EEI-PRT or ISBN 978-1- 4244-3916-4
    • B.K. Gupta, Greg C. Stone, and Jan Stein, Stator Winding Hipot (High Potential) Testing, 2009 IEEE Electrical Insulation Conference, Montreal, QC, May 31-June 3, 2009, IEEE Publication CFP09EEI-PRT or ISBN 978-1- 4244-3916-4, pp 409-413.
    • 2009 IEEE Electrical Insulation Conference , pp. 409-413
    • Gupta, B.K.1    Stone, G.C.2    Stein, J.3
  • 7
    • 1542537741 scopus 로고    scopus 로고
    • The role of AC & DC hipot testing in stator winding ageing
    • Indianapolis, Indiana, September 23-25, IEEE Publication 03CH37480
    • H.G. Sedding, R. Schwabe, J. Stein, and B.K. Gupta, The Role of AC & DC Hipot Testing in Stator Winding Ageing, Proceedings of EIC/EMCW 2003, Indianapolis, Indiana, September 23-25, 2003, IEEE Publication 03CH37480, pp 455-457.
    • (2003) Proceedings of EIC/EMCW 2003 , pp. 455-457
    • Sedding, H.G.1    Schwabe, R.2    Stein, J.3    Gupta, B.K.4
  • 8
    • 77957367045 scopus 로고    scopus 로고
    • Power frequency overpotential tests on installed stator windings of rotating electric machines, panel session on
    • IEEE/PES Winter Meeting, New York, NY, February, IEEE Publication 97TP119-0, 14-17
    • J. Timperley, Power Frequency Overpotential Tests on Installed Stator Windings of Rotating Electric Machines, Panel Session on "High Voltage Testing Of Rotating Machines", IEEE/PES Winter Meeting, New York, NY, February 1997, IEEE Publication 97TP119-0, pp 14-17.
    • (1997) High Voltage Testing of Rotating Machines
    • Timperley, J.1
  • 9
    • 0006858011 scopus 로고    scopus 로고
    • Overpotential testing of insulation in hydro generators, panel session on
    • IEEE/PES Winter Meeting, New York, NY, February, IEEE Publication 97TP119-0
    • R.E. Draper and R.H. Rehder, Overpotential Testing of Insulation in Hydro Generators, Panel Session on "High Voltage Testing Of Rotating Machines", IEEE/PES Winter Meeting, New York, NY, February 1997, IEEE Publication 97TP119-0, pp 10-13.
    • (1997) High Voltage Testing of Rotating Machines , pp. 10-13
    • Draper, R.E.1    Rehder, R.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.