메뉴 건너뛰기




Volumn , Issue , 2010, Pages

Transformer condition analyzing expert system using fuzzy neural system

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL NEURAL NETWORK; DATA SAMPLE; DIAGNOSTIC SYSTEMS; DISSOLVED GAS ANALYSIS; DISSOLVED GAS IN OIL ANALYSIS; FAULT DIAGNOSIS; FUZZY DIAGNOSIS; FUZZY NEURAL SYSTEMS; FUZZY-NEURAL; INCIPIENT FAULTS; LIFE SPAN; NATIONAL STANDARD; OIL IMMERSED TRANSFORMERS; OPERATING CONDITION; POWER SYSTEMS; SYSTEM DEVELOPMENT; TAP CHANGERS; VOLTAGE LEVELS;

EID: 77957355116     PISSN: 01642006     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ELINSL.2010.5549779     Document Type: Conference Paper
Times cited : (20)

References (10)
  • 3
    • 0035761479 scopus 로고    scopus 로고
    • A fuzzy dissolved gas analysis method for the diagnosis of multiple incipient faults in a transformer
    • Hong Kong, October
    • Q. Su, L.L. Lai, P. Austin, "A Fuzzy Dissolved Gas Analysis Method for the Diagnosis of Multiple Incipient Faults in a Transformer." Proceedings of the 5th APSCOM, 2MU., Hong Kong, October 2000., pp. 344-348.
    • (2000) Proceedings of the 5th APSCOM, 2MU , pp. 344-348
    • Su, Q.1    Lai, L.L.2    Austin, P.3
  • 4
    • 0033750975 scopus 로고    scopus 로고
    • A novel fuzzy logic approach to transformer fault diagnosis
    • April
    • S.M. Islam et al., "A Novel Fuzzy Logic Approach to Transformer Fault Diagnosis." IEEE Transactions and Dielectrics and Electrical Insulation, April 2000. Vol. 7., No. 2., pp. 177-186.
    • (2000) IEEE Transactions and Dielectrics and Electrical Insulation , vol.7 , Issue.2 , pp. 177-186
    • Islam, S.M.1
  • 5
    • 84856358444 scopus 로고    scopus 로고
    • Improvement of Dissolved Gas Analysis (DGA) by means of experimental investigations of generated fault gases and a fuzzy logic based interpretation scheme
    • Slovenia, August, T7-157
    • J. Aragón-Patil* et al., "Improvement of Dissolved Gas Analysis (DGA) by means of Experimental Investigations of Generated Fault Gases and a Fuzzy Logic Based Interpretation Scheme." XV International Symposium on High Voltage Engineering the University of Ljubljana, Slovenia, August 27-31, 2007., T7-157.
    • (2007) XV International Symposium on High Voltage Engineering the University of Ljubljana , pp. 27-31
    • Aragón-Patilal, J.1
  • 6
    • 0035248143 scopus 로고    scopus 로고
    • FLVQ networks for power transformer condition assessment
    • February
    • Yang et al., "FLVQ Networks for Power Transformer Condition Assessment." IEEE Transactions on Dielectrics and Electrical Insulation, February 2001., Vol. 8 No. 1, pp. 143-149.
    • (2001) IEEE Transactions on Dielectrics and Electrical Insulation , vol.8 , Issue.1 , pp. 143-149
    • Yang1
  • 9
    • 0035481368 scopus 로고    scopus 로고
    • A comparative study of neural network efficiency in power transformers diagnosis using dissolved gas analysis
    • October
    • J. L. Guardado, J. L. Naredo, P. Moreno, and C. R. Fuerte, "A Comparative Study of Neural Network Efficiency in Power Transformers Diagnosis using Dissolved Gas Analysis," IEEE Trans. Power Del., October 2001., Vol. 16, No. 4, pp. 643-647.
    • (2001) IEEE Trans. Power Del. , vol.16 , Issue.4 , pp. 643-647
    • Guardado, J.L.1    Naredo, J.L.2    Moreno, P.3    Fuerte, C.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.