메뉴 건너뛰기




Volumn , Issue , 2009, Pages 61-93

Biomechanical Modeling of Stents. Survey 1997-2007.

Author keywords

[No Author keywords available]

Indexed keywords


EID: 77957343409     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-0-444-53075-2.00002-2     Document Type: Chapter
Times cited : (5)

References (72)
  • 2
    • 0036315739 scopus 로고    scopus 로고
    • Coronary artery stents: evaluating new designs for contemporary percutaneous intervention
    • Kandzari D.E., Tcheng J.E., Zidar J.P. Coronary artery stents: evaluating new designs for contemporary percutaneous intervention. Catherization and Cardiovascular Interventions 2002, 56(4):562-576.
    • (2002) Catherization and Cardiovascular Interventions , vol.56 , Issue.4 , pp. 562-576
    • Kandzari, D.E.1    Tcheng, J.E.2    Zidar, J.P.3
  • 4
    • 2442493094 scopus 로고    scopus 로고
    • The influence of physical stent parameters upon restenosis
    • Morton A.C., Crossman D., Gunn J. The influence of physical stent parameters upon restenosis. Pathol Biol (Paris) 2004, 52(4):196-205.
    • (2004) Pathol Biol (Paris) , vol.52 , Issue.4 , pp. 196-205
    • Morton, A.C.1    Crossman, D.2    Gunn, J.3
  • 5
    • 0033525544 scopus 로고    scopus 로고
    • Balloon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury
    • Rogers C., Tseng D.Y., Squire J.C., Edelman E.R. Balloon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury. Circ Res. 1999, 84(4):378-383.
    • (1999) Circ Res. , vol.84 , Issue.4 , pp. 378-383
    • Rogers, C.1    Tseng, D.Y.2    Squire, J.C.3    Edelman, E.R.4
  • 6
    • 33344459110 scopus 로고    scopus 로고
    • Role of shear stress in atherosclerosis and restenosis after coronary stent implantation
    • Mongrain R., Rodes-Cabau J. Role of shear stress in atherosclerosis and restenosis after coronary stent implantation. Rev Esp Cardiol. 2006, 59(1):1-4.
    • (2006) Rev Esp Cardiol. , vol.59 , Issue.1 , pp. 1-4
    • Mongrain, R.1    Rodes-Cabau, J.2
  • 10
    • 24644523719 scopus 로고    scopus 로고
    • Incremental cost-effectiveness of drug-eluting stents compared with a third-generation bare-metal stent in a real-world setting: randomised Basel Stent Kosten Effektivitats Trial (BASKET)
    • Kaiser C., Brunner-La Rocca H.P., Buser P.T., Bonetti P.O., Osswald S., Linka A., Bernheim A., Zutter A., Zellweger M., Grize L., Pfisterer M.E. Incremental cost-effectiveness of drug-eluting stents compared with a third-generation bare-metal stent in a real-world setting: randomised Basel Stent Kosten Effektivitats Trial (BASKET). Lancet 2005, 366(9489):921-929.
    • (2005) Lancet , vol.366 , Issue.9489 , pp. 921-929
    • Kaiser, C.1    Brunner-La Rocca, H.P.2    Buser, P.T.3    Bonetti, P.O.4    Osswald, S.5    Linka, A.6    Bernheim, A.7    Zutter, A.8    Zellweger, M.9    Grize, L.10    Pfisterer, M.E.11
  • 13
    • 25644443215 scopus 로고    scopus 로고
    • Finite element modelling and simulations in cardiovascular mechanics and cardiology: a bibliography 1993-2004
    • Mackerle J. Finite element modelling and simulations in cardiovascular mechanics and cardiology: a bibliography 1993-2004. Comput Methods Biomech Biomed Engin 2005, 8(2):59-81.
    • (2005) Comput Methods Biomech Biomed Engin , vol.8 , Issue.2 , pp. 59-81
    • Mackerle, J.1
  • 15
    • 84882557369 scopus 로고    scopus 로고
    • UGCT
    • UGCT. http://www.UGCT.UGent.be.
  • 18
    • 0038610567 scopus 로고    scopus 로고
    • The stress-strain behavior of coronary stent struts is size dependent
    • Murphy B.P., Savage P., McHugh P.E., Quinn D.F. The stress-strain behavior of coronary stent struts is size dependent. Ann Biomed Eng. 2003, 31(6):686-691.
    • (2003) Ann Biomed Eng. , vol.31 , Issue.6 , pp. 686-691
    • Murphy, B.P.1    Savage, P.2    McHugh, P.E.3    Quinn, D.F.4
  • 22
    • 0034333737 scopus 로고    scopus 로고
    • Mechanical behaviour modelling of balloon-expandable stents
    • Dumoulin C., Cochelin B. Mechanical behaviour modelling of balloon-expandable stents. J Biomech. 2000, 33(11):1461-1470.
    • (2000) J Biomech. , vol.33 , Issue.11 , pp. 1461-1470
    • Dumoulin, C.1    Cochelin, B.2
  • 23
    • 84871513333 scopus 로고    scopus 로고
    • Finite element analysis of a stenotic artery revascularization through a stent insertion
    • Auricchio F., Di Loreto M., Sacco E. Finite element analysis of a stenotic artery revascularization through a stent insertion. Comput Methods Biomech Biomed Engin 2001, 4:249-263.
    • (2001) Comput Methods Biomech Biomed Engin , vol.4 , pp. 249-263
    • Auricchio, F.1    Di Loreto, M.2    Sacco, E.3
  • 24
    • 0034930155 scopus 로고    scopus 로고
    • Mechanical properties of coronary stents determined by using finite element analysis
    • Etave F., Finet G., Boivin M., Boyer J.C., Rioufol G., Thollet G. Mechanical properties of coronary stents determined by using finite element analysis. J Biomech. 2001, 34(8):1065-1075.
    • (2001) J Biomech. , vol.34 , Issue.8 , pp. 1065-1075
    • Etave, F.1    Finet, G.2    Boivin, M.3    Boyer, J.C.4    Rioufol, G.5    Thollet, G.6
  • 25
    • 0036000226 scopus 로고    scopus 로고
    • Mechanical behavior of coronary stents investigated through the finite element method
    • Migliavacca F., Petrini L., Colombo M., Auricchio F., Pietrabissa R. Mechanical behavior of coronary stents investigated through the finite element method. J Biomech. 2002, 35(6):803-811.
    • (2002) J Biomech. , vol.35 , Issue.6 , pp. 803-811
    • Migliavacca, F.1    Petrini, L.2    Colombo, M.3    Auricchio, F.4    Pietrabissa, R.5
  • 26
    • 7544232441 scopus 로고    scopus 로고
    • Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modelling
    • McGarry J., O'Donnell B., McHugh P., McGarry J.G. Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modelling. Comp Mater Sci. 2004, 31:421-438.
    • (2004) Comp Mater Sci. , vol.31 , pp. 421-438
    • McGarry, J.1    O'Donnell, B.2    McHugh, P.3    McGarry, J.G.4
  • 27
    • 18044372225 scopus 로고    scopus 로고
    • Finite element analysis of covered microstents
    • Gu L., Santra S., Mericle R.A., Kumar A.V. Finite element analysis of covered microstents. J Biomech. 2005, 38(6):1221-1227.
    • (2005) J Biomech. , vol.38 , Issue.6 , pp. 1221-1227
    • Gu, L.1    Santra, S.2    Mericle, R.A.3    Kumar, A.V.4
  • 28
    • 16344362656 scopus 로고    scopus 로고
    • Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs
    • Holzapfel G.A., Stadler M., Gasser T.C. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs. J Biomech Eng. 2005, 127(1):166-180.
    • (2005) J Biomech Eng. , vol.127 , Issue.1 , pp. 166-180
    • Holzapfel, G.A.1    Stadler, M.2    Gasser, T.C.3
  • 29
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stresses: a finite element analysis
    • Lally C., Dolan F., Prendergast P.J. Cardiovascular stent design and vessel stresses: a finite element analysis. J Biomech. 2005, 38(8):1574-1581.
    • (2005) J Biomech. , vol.38 , Issue.8 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 32
    • 34147182302 scopus 로고    scopus 로고
    • Plasticity in the mechanical behaviour of cardiovascular stents during stent preparation (crimping) and placement (expansion)
    • De Beule M., Mortier P., Van Impe R., Verhegghe B., Segers P., Verdonck P. Plasticity in the mechanical behaviour of cardiovascular stents during stent preparation (crimping) and placement (expansion). Key Eng Mater. 2007, 340-341:847-852.
    • (2007) Key Eng Mater. , vol.340-341 , pp. 847-852
    • De Beule, M.1    Mortier, P.2    Van Impe, R.3    Verhegghe, B.4    Segers, P.5    Verdonck, P.6
  • 34
    • 33750378236 scopus 로고    scopus 로고
    • Effects of stent design parameters on normal artery wall mechanics
    • Bedoya J., Meyer C.A., Timmins L.H., Moreno M.R., Moore J.E. Effects of stent design parameters on normal artery wall mechanics. J Biomech Eng. 2006, 128(5):757-765.
    • (2006) J Biomech Eng. , vol.128 , Issue.5 , pp. 757-765
    • Bedoya, J.1    Meyer, C.A.2    Timmins, L.H.3    Moreno, M.R.4    Moore, J.E.5
  • 37
    • 0035982807 scopus 로고    scopus 로고
    • A layer-specific three-dimensional model for the simulation of balloon angioplasty using magnetic resonance imaging and mechanical testing
    • Holzapfel G.A., Stadler M., Schulze-Bauer C.A.J. A layer-specific three-dimensional model for the simulation of balloon angioplasty using magnetic resonance imaging and mechanical testing. Ann Biomed Eng. 2002, 30(6):753-767.
    • (2002) Ann Biomed Eng. , vol.30 , Issue.6 , pp. 753-767
    • Holzapfel, G.A.1    Stadler, M.2    Schulze-Bauer, C.A.J.3
  • 38
    • 25444471259 scopus 로고    scopus 로고
    • Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery
    • Liang D.K., Yang D.Z., Qi M., Wang W.Q. Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery. Int J Cardiol. 2005, 104(3):314-318.
    • (2005) Int J Cardiol. , vol.104 , Issue.3 , pp. 314-318
    • Liang, D.K.1    Yang, D.Z.2    Qi, M.3    Wang, W.Q.4
  • 39
    • 33748250062 scopus 로고    scopus 로고
    • Intramural stress increases exponentially with stent diameter: a stress threshold for neointimal hyperplasia
    • Ballyk P.D. Intramural stress increases exponentially with stent diameter: a stress threshold for neointimal hyperplasia. J Vasc Interv Radiol. 2006, 17(7):1139-1145.
    • (2006) J Vasc Interv Radiol. , vol.17 , Issue.7 , pp. 1139-1145
    • Ballyk, P.D.1
  • 40
    • 28844502833 scopus 로고    scopus 로고
    • Fatigue and life prediction for cobalt-chromium stents: a fracture mechanics analysis
    • Marrey R.V., Burgermeister R., Grishaber R.B., Ritchie R.O. Fatigue and life prediction for cobalt-chromium stents: a fracture mechanics analysis. Biomaterials 2006, 27(9):1988-2000.
    • (2006) Biomaterials , vol.27 , Issue.9 , pp. 1988-2000
    • Marrey, R.V.1    Burgermeister, R.2    Grishaber, R.B.3    Ritchie, R.O.4
  • 41
    • 33750338097 scopus 로고    scopus 로고
    • Comparison of element technologies for modeling stent expansion
    • Hall G.J., Kasper E.P. Comparison of element technologies for modeling stent expansion. J Biomech Eng. 2006, 128(5):751-756.
    • (2006) J Biomech Eng. , vol.128 , Issue.5 , pp. 751-756
    • Hall, G.J.1    Kasper, E.P.2
  • 42
    • 27744557004 scopus 로고    scopus 로고
    • Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method
    • Wang W.-Q., Liang D.-K., Yang D.-Z., Qi M. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method. J Biomech. 2006, 39(1):21-32.
    • (2006) J Biomech. , vol.39 , Issue.1 , pp. 21-32
    • Wang, W.-Q.1    Liang, D.-K.2    Yang, D.-Z.3    Qi, M.4
  • 43
    • 33845296472 scopus 로고    scopus 로고
    • Simulation and experimental observation of contact conditions between stents and artery models
    • Takashima K., Kitou T., Mori K., Ikeuchi K. Simulation and experimental observation of contact conditions between stents and artery models. Med Eng Phys. 2007, 29(3):326-335.
    • (2007) Med Eng Phys. , vol.29 , Issue.3 , pp. 326-335
    • Takashima, K.1    Kitou, T.2    Mori, K.3    Ikeuchi, K.4
  • 44
    • 34447645340 scopus 로고    scopus 로고
    • Stent expansion in curved vessel and their interactions: a finite element analysis
    • Wu W., Wang W.-Q., Yang D.-Z., Qi M. Stent expansion in curved vessel and their interactions: a finite element analysis. J Biomech. 2007, 10.1016/j.jbiomech.2006.11.009.
    • (2007) J Biomech.
    • Wu, W.1    Wang, W.-Q.2    Yang, D.-Z.3    Qi, M.4
  • 45
    • 0035079178 scopus 로고    scopus 로고
    • A method for investigating the mechanical properties of intracoronary stents using finite element numerical simulation
    • Tan L.B., Webb D.C., Kormi K., Al-Hassani S.T. A method for investigating the mechanical properties of intracoronary stents using finite element numerical simulation. Int J Cardiol. 2001, 78(1):51-67.
    • (2001) Int J Cardiol. , vol.78 , Issue.1 , pp. 51-67
    • Tan, L.B.1    Webb, D.C.2    Kormi, K.3    Al-Hassani, S.T.4
  • 46
    • 0142231887 scopus 로고    scopus 로고
    • Analysis of prolapse in cardiovascular stents: a constitutive equation for vascular tissue and finite-element modelling
    • Prendergast P.J., Lally C., Daly S., Reid A.J., Lee T.C., Quinn D., Dolan F. Analysis of prolapse in cardiovascular stents: a constitutive equation for vascular tissue and finite-element modelling. J Biomech Eng. 2003, 125(5):692-699.
    • (2003) J Biomech Eng. , vol.125 , Issue.5 , pp. 692-699
    • Prendergast, P.J.1    Lally, C.2    Daly, S.3    Reid, A.J.4    Lee, T.C.5    Quinn, D.6    Dolan, F.7
  • 47
    • 1442299848 scopus 로고    scopus 로고
    • Numerical investigation of the intravascular coronary stent flexibility
    • Petrini L., Migliavacca F., Auricchio F., Dubini G. Numerical investigation of the intravascular coronary stent flexibility. J Biomech. 2004, 37(4):495-501.
    • (2004) J Biomech. , vol.37 , Issue.4 , pp. 495-501
    • Petrini, L.1    Migliavacca, F.2    Auricchio, F.3    Dubini, G.4
  • 48
    • 21144448039 scopus 로고    scopus 로고
    • Effects of stent structure on stent flexibility measurements
    • Mori K., Saito T. Effects of stent structure on stent flexibility measurements. Ann Biomed Eng. 2005, 33(6):733-742.
    • (2005) Ann Biomed Eng. , vol.33 , Issue.6 , pp. 733-742
    • Mori, K.1    Saito, T.2
  • 49
    • 2942597872 scopus 로고    scopus 로고
    • Coronary stent strut size dependent stress-strain response investigated using micromechanical finite element models
    • Savage P., O'Donnell B.P., McHugh P.E., Murphy B.P., Quinn D.F. Coronary stent strut size dependent stress-strain response investigated using micromechanical finite element models. Ann Biomed Eng. 2004, 32(2):202-211.
    • (2004) Ann Biomed Eng. , vol.32 , Issue.2 , pp. 202-211
    • Savage, P.1    O'Donnell, B.P.2    McHugh, P.E.3    Murphy, B.P.4    Quinn, D.F.5
  • 50
    • 0001040614 scopus 로고    scopus 로고
    • Simulation of in vivo loading conditions of nitinol vascular stent structures
    • Whitcher F. Simulation of in vivo loading conditions of nitinol vascular stent structures. Comput Struct. 1997, 64(5/6):1005-1011.
    • (1997) Comput Struct. , vol.64 , Issue.5-6 , pp. 1005-1011
    • Whitcher, F.1
  • 51
    • 10444282238 scopus 로고    scopus 로고
    • Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall
    • Migliavacca F., Petrini L., Massarotti P., Schievano S., Auricchio F., Dubini G. Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall. Biomech Model Mechanobiol. 2004, 2(4):205-217.
    • (2004) Biomech Model Mechanobiol. , vol.2 , Issue.4 , pp. 205-217
    • Migliavacca, F.1    Petrini, L.2    Massarotti, P.3    Schievano, S.4    Auricchio, F.5    Dubini, G.6
  • 53
    • 33750380924 scopus 로고    scopus 로고
    • Finite element modeling of a progressively expanding shape memory stent
    • Theriault P., Terriault P., Brailovski V., Gallo R. Finite element modeling of a progressively expanding shape memory stent. J Biomech. 2006, 39(15):2837-2844.
    • (2006) J Biomech. , vol.39 , Issue.15 , pp. 2837-2844
    • Theriault, P.1    Terriault, P.2    Brailovski, V.3    Gallo, R.4
  • 54
    • 34548593681 scopus 로고    scopus 로고
    • Delivery and release of nitinol stent in carotid artery and their interactions: a finite element analysis
    • Wu W., Qi M., Liu X., Yang D., Wang W. Delivery and release of nitinol stent in carotid artery and their interactions: a finite element analysis. J Biomech. 2007, 10.1016/j.jbiomech.2007.02.024.
    • (2007) J Biomech.
    • Wu, W.1    Qi, M.2    Liu, X.3    Yang, D.4    Wang, W.5
  • 55
    • 0035100742 scopus 로고    scopus 로고
    • Use of metallic stents balloonsthe esophagus gastrointestinal tract
    • Morgan R., Adam A. Use of metallic stents balloonsthe esophagus gastrointestinal tract. J Vasc Interv Radiol. 2001, 12(3):283-297.
    • (2001) J Vasc Interv Radiol. , vol.12 , Issue.3 , pp. 283-297
    • Morgan, R.1    Adam, A.2
  • 57
    • 2342572329 scopus 로고    scopus 로고
    • Clinical outcomes with airway stents for proximal versus distal malignant tracheobronchial obstructions
    • Walser E.M., Robinson B., Raza S.A., Ozkan O.S., Ustuner E., Zwischenberger J. Clinical outcomes with airway stents for proximal versus distal malignant tracheobronchial obstructions. J Vasc Interv Radiol. 2004, 15(5):471-477.
    • (2004) J Vasc Interv Radiol. , vol.15 , Issue.5 , pp. 471-477
    • Walser, E.M.1    Robinson, B.2    Raza, S.A.3    Ozkan, O.S.4    Ustuner, E.5    Zwischenberger, J.6
  • 58
    • 33746862198 scopus 로고    scopus 로고
    • Use of a partially deployed wallstent to act as an inferior vena cava filtration device during coil embolization of a high-flow arteriovenous fistula
    • Resnick S., Rome V., Vogelzang R. Use of a partially deployed wallstent to act as an inferior vena cava filtration device during coil embolization of a high-flow arteriovenous fistula. J Vasc Interv Radiol. 2006, 17(2 Pt 1):369-372.
    • (2006) J Vasc Interv Radiol. , vol.17 , Issue.2 PT 1 , pp. 369-372
    • Resnick, S.1    Rome, V.2    Vogelzang, R.3
  • 59
    • 0027567438 scopus 로고
    • A study of the geometrical and mechanical properties of a self-expanding metallic stent-theory and experiment
    • Jedwab M.R., Clerc C.O. A study of the geometrical and mechanical properties of a self-expanding metallic stent-theory and experiment. J Appl Biomater. 1993, 4(1):77-85.
    • (1993) J Appl Biomater. , vol.4 , Issue.1 , pp. 77-85
    • Jedwab, M.R.1    Clerc, C.O.2
  • 60
    • 12344281943 scopus 로고    scopus 로고
    • Mechanical response of a metallic aortic stent - Part I: Pressure-diameter relationship
    • Wang R., Ravi-Chandar K. Mechanical response of a metallic aortic stent - Part I: Pressure-diameter relationship. J Appl Mech. 2004, 71:697-705.
    • (2004) J Appl Mech. , vol.71 , pp. 697-705
    • Wang, R.1    Ravi-Chandar, K.2
  • 61
    • 12344262933 scopus 로고    scopus 로고
    • Mechanical response of a metallic aortic stent - Part II: A beam on elastic foundation model
    • Wang R., Ravi-Chandar K. Mechanical response of a metallic aortic stent - Part II: A beam on elastic foundation model. J Appl Mech. 2004, 71:706-712.
    • (2004) J Appl Mech. , vol.71 , pp. 706-712
    • Wang, R.1    Ravi-Chandar, K.2
  • 62
    • 33244492139 scopus 로고    scopus 로고
    • Mathematical model analysis of Wallstent and AneuRx - dynamic responses of bare-metal endoprosthesis compared with those of stent-graft
    • Canic S., Ravi-Chandar K., Krajcer Z., Mirkovic D., Lapin S. Mathematical model analysis of Wallstent and AneuRx - dynamic responses of bare-metal endoprosthesis compared with those of stent-graft. Tex Heart I J 2005, 32(4):502-506.
    • (2005) Tex Heart I J , vol.32 , Issue.4 , pp. 502-506
    • Canic, S.1    Ravi-Chandar, K.2    Krajcer, Z.3    Mirkovic, D.4    Lapin, S.5
  • 63
    • 18644368989 scopus 로고    scopus 로고
    • The cardiocoil stent-artery interaction
    • Brand M., Ryvkin M., Einav S., Slepyan L. The cardiocoil stent-artery interaction. J Biomech Eng. 2005, 127(2):337-344.
    • (2005) J Biomech Eng. , vol.127 , Issue.2 , pp. 337-344
    • Brand, M.1    Ryvkin, M.2    Einav, S.3    Slepyan, L.4
  • 64
    • 0042172955 scopus 로고    scopus 로고
    • Theoretical and experimental evaluation of the radial force of self-expanding braided bioabsorbable stents
    • Nuutinen J.-P., Clerc C., Tormala P. Theoretical and experimental evaluation of the radial force of self-expanding braided bioabsorbable stents. J Biomater Sci Polym Ed. 2003, 14(7):677-687.
    • (2003) J Biomater Sci Polym Ed. , vol.14 , Issue.7 , pp. 677-687
    • Nuutinen, J.-P.1    Clerc, C.2    Tormala, P.3
  • 65
    • 0035985035 scopus 로고    scopus 로고
    • Computational fluid dynamics and stent design
    • Frank A.O., Walsh P.W., Moore J.E.J. Computational fluid dynamics and stent design. Artif Organs 2002, 26(7):614-621.
    • (2002) Artif Organs , vol.26 , Issue.7 , pp. 614-621
    • Frank, A.O.1    Walsh, P.W.2    Moore, J.E.J.3
  • 66
    • 23644444112 scopus 로고    scopus 로고
    • Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions
    • He Y., Duraiswamy N., Frank A.O., Moore J.E.J. Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. J Biomech Eng. 2005, 127(4):637-647.
    • (2005) J Biomech Eng. , vol.127 , Issue.4 , pp. 637-647
    • He, Y.1    Duraiswamy, N.2    Frank, A.O.3    Moore, J.E.J.4
  • 67
    • 14144250735 scopus 로고    scopus 로고
    • Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models
    • LaDisa J.F.J., Olson L.E., Guler I., Hettrick D.A., Kersten J.R., Warltier D.C., Pagel P.S. Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models. J Appl Physiol. 2005, 98(3):947-957.
    • (2005) J Appl Physiol. , vol.98 , Issue.3 , pp. 947-957
    • LaDisa, J.F.J.1    Olson, L.E.2    Guler, I.3    Hettrick, D.A.4    Kersten, J.R.5    Warltier, D.C.6    Pagel, P.S.7
  • 68
    • 33748766360 scopus 로고    scopus 로고
    • Computational approach to estimating the effects of blood properties on changes in intra-stent flow
    • Benard N., Perrault R., Coisne D. Computational approach to estimating the effects of blood properties on changes in intra-stent flow. Ann Biomed Eng. 2006, 34(8):1259-1271.
    • (2006) Ann Biomed Eng. , vol.34 , Issue.8 , pp. 1259-1271
    • Benard, N.1    Perrault, R.2    Coisne, D.3
  • 69
    • 20444432377 scopus 로고    scopus 로고
    • Strut position, blood flow, and drug deposition: implications for single and overlapping drug-eluting stents
    • Balakrishnan B., Tzafriri A.R., Seifert P., Groothuis A., Rogers C., Edelman E.R. Strut position, blood flow, and drug deposition: implications for single and overlapping drug-eluting stents. Circulation 2005, 111(22):2958-2965.
    • (2005) Circulation , vol.111 , Issue.22 , pp. 2958-2965
    • Balakrishnan, B.1    Tzafriri, A.R.2    Seifert, P.3    Groothuis, A.4    Rogers, C.5    Edelman, E.R.6
  • 70
    • 33646172838 scopus 로고    scopus 로고
    • Stent modeling using immersed finite element method
    • Gay M., Zhang L., Liu W.K. Stent modeling using immersed finite element method. Comput Methods Appl Mech Eng. 2006, 195:4358-4370.
    • (2006) Comput Methods Appl Mech Eng. , vol.195 , pp. 4358-4370
    • Gay, M.1    Zhang, L.2    Liu, W.K.3
  • 72
    • 84882483067 scopus 로고    scopus 로고
    • Stent-Research-Unit
    • Stent-Research-Unit. http://www.stent-IBiTech.UGent.be.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.