메뉴 건너뛰기




Volumn 14, Issue 3, 2010, Pages 143-149

Radial Column and Volar Plating (RCVP) for distal radius fractures with a radial styloid component or severe comminution

Author keywords

distal radius fracture; radial column plating; volar plating

Indexed keywords

ARTICLE; BONE PLATE; BONE SCREW; COMMINUTED FRACTURE; HUMAN; KIRSCHNER WIRE; METHODOLOGY; OSTEOSYNTHESIS; RADIUS; RADIUS FRACTURE;

EID: 77957332209     PISSN: 10893393     EISSN: 15316572     Source Type: Journal    
DOI: 10.1097/BTH.0b013e3181cae14d     Document Type: Article
Times cited : (13)

References (18)
  • 1
    • 77957366408 scopus 로고
    • Incidence and costs to the medicare of fractures among medicare beneficiaries aged 65 years-United States
    • JA, and, July 1991-June, October 18, 1996, cited; 45: Available from:
    • JA Baron JB and Berger M. Incidence and costs to the Medicare of fractures among Medicare Beneficiaries Aged 65 Years-United States, July 1991-June 1992. Morbidity and Mortality Weekly Report October 18, 1996 [cited; 45: (Available from: http://www.cdc.gov/epo/mmwr/mmwr.html.)]
    • (1992) Morbidity and Mortality Weekly Report
    • Baron, J.B.1    Berger, M.2
  • 2
    • 33745994558 scopus 로고    scopus 로고
    • Epidemiology of adult fractures: A review
    • Court-Brown CM, Caesar B. Epidemiology of adult fractures: a review. Injury. 2006;37:691-697.
    • (2006) Injury , vol.37 , pp. 691-697
    • Court-Brown, C.M.1    Caesar, B.2
  • 4
    • 35448986115 scopus 로고    scopus 로고
    • Management of distal radial fractures
    • Chen NC, Jupiter JB. Management of distal radial fractures. J Bone Joint Surg. 2007;89:2051-2062.
    • (2007) J. Bone Joint Surg. , vol.89 , pp. 2051-2062
    • Chen, N.C.1    Jupiter, J.B.2
  • 5
    • 0001438511 scopus 로고    scopus 로고
    • Immediate internal fixation and motion of comminuted distal radius fractures using a new fragment specific fixation system
    • Medoff RJ, Kopylov P. Immediate internal fixation and motion of comminuted distal radius fractures using a new fragment specific fixation system. Orthop Trans. 1998;22:165.
    • (1998) Orthop. Trans. , vol.22 , pp. 165
    • Medoff, R.J.1    Kopylov, P.2
  • 6
    • 0004911688 scopus 로고    scopus 로고
    • Open reduction and immediate motion of intraarticular distal radius fractures with a fragment specific fixation system
    • Medoff RJ, Kopylov P. Open reduction and immediate motion of intraarticular distal radius fractures with a fragment specific fixation system. Arch Am Acad Orthop Surg. 1999;2:53-61.
    • (1999) Arch. Am. Acad. Orthop. Surg. , vol.2 , pp. 53-61
    • Medoff, R.J.1    Kopylov, P.2
  • 7
    • 67651173348 scopus 로고    scopus 로고
    • Unstable distal radius fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial
    • Wei DH, Raizman NM, Bottino CJ, et al. Unstable distal radius fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial. J Bone Joint Surg Am. 2009;91:1568-1577.
    • (2009) J. Bone Joint Surg. Am. , vol.91 , pp. 1568-1577
    • Wei, D.H.1    Raizman, N.M.2    Bottino, C.J.3
  • 8
    • 0030010872 scopus 로고    scopus 로고
    • Fractures of the distal end of the radius treated by internal fixation and early function: A preliminary report of 20 cases
    • Rikli D, Regazzoni P. Fractures of the distal end of the radius treated by internal fixation and early function: a preliminary report of 20 cases. J Bone Joint Surg Br. 1996;78:588-592.
    • (1996) J. Bone Joint Surg. Br. , vol.78 , pp. 588-592
    • Rikli, D.1    Regazzoni, P.2
  • 9
    • 0034097721 scopus 로고    scopus 로고
    • Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients
    • Jakob M, Rikli DA, Regazzoni P. Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients. J Bone Joint Surg Br. 2000;82:340-344.
    • (2000) J. Bone Joint Surg. Br. , vol.82 , pp. 340-344
    • Jakob, M.1    Rikli, D.A.2    Regazzoni, P.3
  • 10
    • 0033976014 scopus 로고    scopus 로고
    • Comparison of three different plating techniques for the dorsum of the distal radius: A biomechanical study
    • Peine R, Rikli D, Hoffman R, et al. Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study. J Hand Surg Am. 2000;25A:29-33.
    • (2000) J. Hand Surg. Am. , vol.25 A , pp. 29-33
    • Peine, R.1    Rikli, D.2    Hoffman, R.3
  • 11
    • 35748981228 scopus 로고    scopus 로고
    • Fragment-specific fracture fixation and double-column plating of unstable distal radius fractures using AO mini-fragment implants and Kirschner wires
    • Chang HC, Poh SY, Seah SC, et al. Fragment-specific fracture fixation and double-column plating of unstable distal radius fractures using AO mini-fragment implants and Kirschner wires. Injury. 2007;38:1259-1267.
    • (2007) Injury , vol.38 , pp. 1259-1267
    • Chang, H.C.1    Poh, S.Y.2    Seah, S.C.3
  • 12
    • 3543045554 scopus 로고    scopus 로고
    • Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius
    • Ring D, Prommersberger K, Jupiter JB. Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius. J Bone Joint Surg Am. 2004;86A:1646-1652.
    • (2004) J. Bone Joint Surg. Am. , vol.86 A , pp. 1646-1652
    • Ring, D.1    Prommersberger, K.2    Jupiter, J.B.3
  • 13
    • 0004136708 scopus 로고
    • Exposure of the whole shaft of the radius from in front with extensions to median and ulnar nerves
    • Henry AK, ed, 2nd ed. Edinburgh: E. & S. Livingstone
    • Henry AK. Exposure of the whole shaft of the radius from in front with extensions to median and ulnar nerves. In: Henry AK, ed. Extensile Exposure. 2nd ed. Edinburgh: E. & S. Livingstone; 1970:100-106.
    • (1970) Extensile Exposure , pp. 100-106
    • Henry, A.K.1
  • 14
    • 33846624729 scopus 로고    scopus 로고
    • Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragmentspecific fixation in a cadaveric distal radius fracture model
    • Grindel SI, Wang M, Gerlach M, et al. Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragmentspecific fixation in a Cadaveric Distal Radius Fracture Model. J Hand Surg Am. 2007;32A:194-199.
    • (2007) J. Hand Surg. Am. , vol.32 A , pp. 194-199
    • Grindel, S.I.1    Wang, M.2    Gerlach, M.3
  • 15
  • 16
    • 0034821880 scopus 로고    scopus 로고
    • Volar approach to dorsal displaced fractures of the distal radius
    • Henry MH, Griggs SM, Levaro F, et al. Volar approach to dorsal displaced fractures of the distal radius. Tech Hand Up Extrem Surg. 2001;5:31-41.
    • (2001) Tech. Hand Up Extrem Surg. , vol.5 , pp. 31-41
    • Henry, M.H.1    Griggs, S.M.2    Levaro, F.3
  • 17
    • 50249099846 scopus 로고    scopus 로고
    • Precontoured fixed-angle volar distal radius plates: A comparison of anatomic fit
    • Buzzell JE, Weikert DR, Watson JT, et al. Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg. 2008;33:1144-1152.
    • (2008) J. Hand Surg. , vol.33 , pp. 1144-1152
    • Buzzell, J.E.1    Weikert, D.R.2    Watson, J.T.3
  • 18
    • 39149097204 scopus 로고    scopus 로고
    • Flexor tendon injuries following locked volar plating of distal radius fractures
    • Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg. 2008;33:164-167.
    • (2008) J. Hand Surg. , vol.33 , pp. 164-167
    • Cross, A.W.1    Schmidt, C.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.