Balloon atrial septostomy guided by echocardiography in a neonatal intensive care unit;Atriosseptostomia por cateter balão guiada pela ecocardiografia em unidade de terapia intensiva neonatal

Author keywords

Balloon dilatation; Echocardiography; Heart atria; Heart defects, congenital

Indexed keywords

ARTICLE; BALLOON ATRIAL SEPTOSTOMY; BALLOON CATHETER; FATALITY; FEMALE; GREAT VESSELS TRANSPOSITION; HEART ATRIUM FIBRILLATION; HEART ATRIUM SEPTUM; HEART ATRIUM SEPTUM DEFECT; HEART SURGERY; HEART TAMPONADE; HEART VENTRICLE TACHYCARDIA; HUMAN; HYPOPLASTIC LEFT HEART SYNDROME; MAJOR CLINICAL STUDY; MALE; NEWBORN; NEWBORN INTENSIVE CARE; OUTCOME ASSESSMENT; OXYGEN SATURATION; PALLIATIVE THERAPY; RISK REDUCTION; SURGICAL TECHNIQUE; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 77957300033     PISSN: 0066782X     EISSN: 16784170     Source Type: Journal    
DOI: 10.1590/S0066-782X2010005000076     Document Type: Article
Times cited : (9)

References (16)
  • 1
    • 0014013778 scopus 로고
    • Creation of an atrial septal defect without thoracotomy: A palliative approach to complete transposition of the great arteries
    • Rashkind WJ, Miller WW. Creation of an atrial septal defect without thoracotomy: a palliative approach to complete transposition of the great arteries. JAMA. 1966; 196 (11): 991-2.
    • (1966) JAMA , vol.196 , Issue.11 , pp. 991-992
    • Rashkind, W.J.1    Miller, W.W.2
  • 3
    • 17644385624 scopus 로고
    • The complications of balloon atrioseptostomy
    • Rashkind WJ. The complications of balloon atrioseptostomy. J Pediatrics. 1970; 76 (4): 649-50.
    • (1970) J Pediatrics , vol.76 , Issue.4 , pp. 649-650
    • Rashkind, W.J.1
  • 4
    • 0019407584 scopus 로고
    • Two-dimensional echocardiography for catheter location and placement in infants and children
    • Perry LW, Galioto FM Jr, Blair T, Shapiro SR, Ruckman RN, Scott LP. Two-dimensional echocardiography for catheter location and placement in infants and children. Pediatrics. 1981; 67 (4): 541-7.
    • (1981) Pediatrics , vol.67 , Issue.4 , pp. 541-547
    • Perry, L.W.1    Galioto Jr., F.M.2    Blair, T.3    Shapiro, S.R.4    Ruckman, R.N.5    Scott, L.P.6
  • 5
    • 0019772793 scopus 로고
    • Application of two dimensional echocardiography for the intracardiac manipulation: The evaluation of atrial septal movement before and after balloon atrial septostomy
    • Matsunaga S, Suzuki K, Ichinose E, Takeuchi S, Yoshioka F, Yokochi K, et al. Application of two dimensional echocardiography for the intracardiac manipulation: the evaluation of atrial septal movement before and after balloon atrial septostomy. J Cardiogr. 1981; 11 (1): 217-24.
    • (1981) J Cardiogr , vol.11 , Issue.1 , pp. 217-224
    • Matsunaga, S.1    Suzuki, K.2    Ichinose, E.3    Takeuchi, S.4    Yoshioka, F.5    Yokochi, K.6
  • 7
    • 0020025862 scopus 로고
    • Balloon atrial septostomy under two dimensional echocardiographic control
    • Allan LD, Leanage R, Wainwright R, Joseph MC, Tynan M. Balloon atrial septostomy under two dimensional echocardiographic control. Br Heart J. 1982; 47 (1): 41-3. (Pubitemid 12171548)
    • (1982) British Heart Journal , vol.47 , Issue.1 , pp. 41-43
    • Allan, L.D.1    Leanage, R.2    Wainwright, R.3
  • 10
    • 0031000187 scopus 로고    scopus 로고
    • Balloon atrial septostomy under two-dimensional echocardiographic control: A new outlook
    • Jamjureeruk V, Sangtawesin C, Layangool T. Balloon atrial septostomy under two-dimensional echocardiographic control: a new outlook. Pediatr Cardiol. 1997; 18 (3): 197-200.
    • (1997) Pediatr Cardiol , vol.18 , Issue.3 , pp. 197-200
    • Jamjureeruk, V.1    Sangtawesin, C.2    Layangool, T.3
  • 11
    • 0036499047 scopus 로고    scopus 로고
    • Bedside balloon atrial septostomy is safe, efficacious, and cost-effective compared with septostomy performed in the cardiac catheterization laboratory
    • Zellers TM, Dixon K, Moake L, Wright J, Ramaciotti C. Bedside balloon atrial septostomy is safe, efficacious, and cost-effective compared with septostomy performed in the cardiac catheterization laboratory. Am J Cardiol. 2002; 89 (5): 613-5.
    • (2002) Am J Cardiol , vol.89 , Issue.5 , pp. 613-615
    • Zellers, T.M.1    Dixon, K.2    Moake, L.3    Wright, J.4    Ramaciotti, C.5
  • 13
    • 17144454375 scopus 로고
    • Atriosseptostomia em unidade de terapia intensiva sob monitorização ecocardiográfica: Experiência inicial do Instituto do Coração de Pernambuco
    • et al.
    • Mattos SS, Severi R, Marques DL, Parpinelli RC, Mabesoone PA, Francisco S Fo, et al. et al. Atriosseptostomia em unidade de terapia intensiva sob monitorização ecocardiográfica: experiência inicial do Instituto do Coração de Pernambuco. Arq Bras Cardiol. 1993; 61 (1): 33-6.
    • (1993) Arq Bras Cardiol , vol.61 , Issue.1 , pp. 33-36
    • Mattos, S.S.1    Severi, R.2    Marques, D.L.3    Parpinelli, R.C.4    Mabesoone, P.A.5    Fo, F.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.