Volumn 88, Issue 1, 2011, Pages 265-271

Loss evaluation and design optimisation for direct driven permanent magnet synchronous generators for wind power

Author keywords

Electromagnetic losses; Simulation; Synchronous generators; Wind turbines

Indexed keywords

FINITE ELEMENT METHOD; MAGNETS; MATLAB; PERMANENT MAGNETS; SYNCHRONOUS GENERATORS; WIND POWER; WIND TURBINES;

EID: 77957299203     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2010.06.010     Document Type: Article
Times cited : (37)

References (29)
  • 2
    • 0000676941 scopus 로고
    • Wind energy for the 1990s and beyond
    • Bellarmin G.T., Urquhart J. Wind energy for the 1990s and beyond. Energy Convers Manage 1990, 37(1996):1741-1752.
    • (1990) Energy Convers Manage , vol.37 , Issue.1996 , pp. 1741-1752
    • Bellarmin, G.T.1    Urquhart, J.2
  • 4
    • 84889300676 scopus 로고    scopus 로고
    • Generators and power electronics for wind turbines
    • John Wiley & Sons, Ltd., England, T. Ackermann (Ed.)
    • Hansen A.D. Generators and power electronics for wind turbines. Wind power in power systems 2005, 55-65. John Wiley & Sons, Ltd., England. T. Ackermann (Ed.).
    • (2005) Wind power in power systems , pp. 55-65
    • Hansen, A.D.1
  • 5
    • 85020967461 scopus 로고
    • Turbine having its rotating shaft transverse to the flow of the current. US Patent 1.835.018, December
    • Darrieus GJM. Turbine having its rotating shaft transverse to the flow of the current. US Patent 1.835.018, December 1931.
    • (1931)
    • Darrieus, G.J.M.1
  • 6
    • 41749123209 scopus 로고    scopus 로고
    • Evaluation of different turbine concepts for wind power
    • Eriksson S., Bernhoff H., Leijon M. Evaluation of different turbine concepts for wind power. Renew Sustain Energy Rev 2008, 12(5):1419-1434.
    • (2008) Renew Sustain Energy Rev , vol.12 , Issue.5 , pp. 1419-1434
    • Eriksson, S.1    Bernhoff, H.2    Leijon, M.3
  • 7
    • 84876542774 scopus 로고    scopus 로고
    • Design of a 12kW vertical axis wind turbine equipped with a direct driven PM synchronous generator. In: Eur wind energy conf, Athens, Greece
    • Solum A, Deglaire P, Eriksson S, Stålberg M, Leijon M, Bernhoff H. Design of a 12kW vertical axis wind turbine equipped with a direct driven PM synchronous generator. In: Eur wind energy conf, Athens, Greece; 2006.
    • (2006)
    • Solum, A.1    Deglaire, P.2    Eriksson, S.3    Stålberg, M.4    Leijon, M.5    Bernhoff, H.6
  • 8
    • 84875334710 scopus 로고    scopus 로고
    • Experimental results from a 12kW vertical axis wind turbine with a direct driven PM synchronous generator. In: Eur wind energy conf, Milan, Italy, May
    • Deglaire P, Eriksson S, Kjellin J, Bernhoff H. Experimental results from a 12kW vertical axis wind turbine with a direct driven PM synchronous generator. In: Eur wind energy conf, Milan, Italy, May 2007.
    • (2007)
    • Deglaire, P.1    Eriksson, S.2    Kjellin, J.3    Bernhoff, H.4
  • 9
    • 38049186624 scopus 로고    scopus 로고
    • Simulations and experiments on a 12kW direct driven PM synchronous generator for wind power
    • Eriksson S., Solum A., Bernhoff H., Leijon M. Simulations and experiments on a 12kW direct driven PM synchronous generator for wind power. Renew Energy 2008, 33(4):674-681.
    • (2008) Renew Energy , vol.33 , Issue.4 , pp. 674-681
    • Eriksson, S.1    Solum, A.2    Bernhoff, H.3    Leijon, M.4
  • 10
    • 64549128339 scopus 로고    scopus 로고
    • FEM simulations and experiments of different loading conditions for a 12kW direct driven PM synchronous generator for wind power
    • Article 3
    • Eriksson S., Bernhoff H., Leijon M. FEM simulations and experiments of different loading conditions for a 12kW direct driven PM synchronous generator for wind power. Int J Energy Electr Power Syst 2009, 10(1). Article 3.
    • (2009) Int J Energy Electr Power Syst , vol.10 , Issue.1
    • Eriksson, S.1    Bernhoff, H.2    Leijon, M.3
  • 11
    • 85021011143 scopus 로고    scopus 로고
    • Direct driven generators for vertical axis wind turbines. Comprehensive summaries of Uppsala dissertations from the Faculty of Science and Technology 547; ISBN: 978-91-554-7264-1.
    • Eriksson S. Direct driven generators for vertical axis wind turbines. Comprehensive summaries of Uppsala dissertations from the Faculty of Science and Technology 547; 2008. ISBN: 978-91-554-7264-1.
    • (2008)
    • Eriksson, S.1
  • 12
    • 34548505048 scopus 로고    scopus 로고
    • Investigating the overload capacity of a direct-driven synchronous permanent magnet wind turbine generator designed using high-voltage cable technology
    • Solum A., Leijon M. Investigating the overload capacity of a direct-driven synchronous permanent magnet wind turbine generator designed using high-voltage cable technology. Int J Energy Res 2007, 31(11):1076-1086.
    • (2007) Int J Energy Res , vol.31 , Issue.11 , pp. 1076-1086
    • Solum, A.1    Leijon, M.2
  • 13
    • 0035330350 scopus 로고    scopus 로고
    • Windformer-A recent development in the electrical insulation systems of generators and transformers
    • Leijon M., Dahlgren M., Walfridsson L., Ming L., Jaksts A. Windformer-A recent development in the electrical insulation systems of generators and transformers. IEEE Electr Insul Mag 2001, 17(3):10-15.
    • (2001) IEEE Electr Insul Mag , vol.17 , Issue.3 , pp. 10-15
    • Leijon, M.1    Dahlgren, M.2    Walfridsson, L.3    Ming, L.4    Jaksts, A.5
  • 15
    • 0003393654 scopus 로고
    • Power system stability and control
    • McGraw-Hill, Inc., New York (USA)
    • Kundur P. Power system stability and control. The EPRI power system engineering series 1994, McGraw-Hill, Inc., New York (USA), p. 20-3.
    • (1994) The EPRI power system engineering series , pp. 20-23
    • Kundur, P.1
  • 16
    • 77957318097 scopus 로고    scopus 로고
    • Losses in a directly driven, low-speed permanent-magnet wind generator
    • Skagen, Denmark
    • Lampola P. Losses in a directly driven, low-speed permanent-magnet wind generator. Proc nordic res symp energy effic electr mot drives 1996, 358-364. Skagen, Denmark.
    • (1996) Proc nordic res symp energy effic electr mot drives , pp. 358-364
    • Lampola, P.1
  • 19
    • 0030246236 scopus 로고    scopus 로고
    • Efficiency of three wind energy generator systems
    • Grauers A. Efficiency of three wind energy generator systems. IEEE Trans Energy Convers 1996, 11(3):650-657.
    • (1996) IEEE Trans Energy Convers , vol.11 , Issue.3 , pp. 650-657
    • Grauers, A.1
  • 20
    • 33749042869 scopus 로고    scopus 로고
    • Design of a PM wind generator, optimised for energy capture over a wide operating range.
    • Khan MA, Pillay P. Design of a PM wind generator, optimised for energy capture over a wide operating range. In: Proc IEEE int conf electr mach drives, 15-18 May, 2005. p. 1501-6.
    • (2005) Proc IEEE int conf electr mach drives, 15-18 May , pp. 1501-1506
    • Khan, M.A.1    Pillay, P.2
  • 21
    • 33747049003 scopus 로고    scopus 로고
    • Dependence of the power losses of a non-oriented 3%Si-steel on frequency and gauge
    • Broddefalk A., Lindenmo M. Dependence of the power losses of a non-oriented 3%Si-steel on frequency and gauge. J Magn Magn Mater 2006, 304(2):e586-e588.
    • (2006) J Magn Magn Mater , vol.304 , Issue.2
    • Broddefalk, A.1    Lindenmo, M.2
  • 22
    • 15044359879 scopus 로고    scopus 로고
    • Minimization of iron losses of permanent magnet synchronous machines
    • Mi C.C., Slemon G.R., Bonert R. Minimization of iron losses of permanent magnet synchronous machines. IEEE Trans Energy Convers 2005, 20(1):121-127.
    • (2005) IEEE Trans Energy Convers , vol.20 , Issue.1 , pp. 121-127
    • Mi, C.C.1    Slemon, G.R.2    Bonert, R.3
  • 23
    • 0041764890 scopus 로고    scopus 로고
    • Prediction of iron loss in rotating machines with rotational loss included
    • Ma L., Sanada M., Morimoto S., Takeda Y. Prediction of iron loss in rotating machines with rotational loss included. IEEE Trans Magn 2003, 39(4):2036-2041.
    • (2003) IEEE Trans Magn , vol.39 , Issue.4 , pp. 2036-2041
    • Ma, L.1    Sanada, M.2    Morimoto, S.3    Takeda, Y.4
  • 24
    • 84881374317 scopus 로고    scopus 로고
    • Anon 1. Electric steel non oriented fully processed Cogent, Cogent 2002-11 by SIR-Gruppen Sweden, Surahammars Bruk AB, Box 201, SE-735 23 Surahammar, Sweden.
    • Anon 1. Electric steel non oriented fully processed Cogent, Cogent 2002-11 by SIR-Gruppen Sweden, Surahammars Bruk AB, Box 201, SE-735 23 Surahammar, Sweden.
  • 25
    • 84881371901 scopus 로고    scopus 로고
    • Anon 2. Ace, modified version 3.1, ABB common platform for field analysis and simulations, ABB Corporate Research Centre. ABB AB, Corporate Research, 721 78 Västerås, Sweden.
    • Anon 2. Ace, modified version 3.1, ABB common platform for field analysis and simulations, ABB Corporate Research Centre. ABB AB, Corporate Research, 721 78 Västerås, Sweden.
  • 26
    • 33746354014 scopus 로고    scopus 로고
    • Automated design of a linear generator for wave energy converters - a simplified model
    • Wolfbrandt A. Automated design of a linear generator for wave energy converters - a simplified model. IEEE Trans Magn 2006, 42(7):1812-1819.
    • (2006) IEEE Trans Magn , vol.42 , Issue.7 , pp. 1812-1819
    • Wolfbrandt, A.1
  • 27
    • 26944457367 scopus 로고    scopus 로고
    • Detailed study of the magnetic circuit in a longitudinal flux permanent-magnet synchronous linear generator
    • Danielsson O., Leijon M., Sjostedt E. Detailed study of the magnetic circuit in a longitudinal flux permanent-magnet synchronous linear generator. IEEE Trans Magn 2005, 41(9):2490-2495.
    • (2005) IEEE Trans Magn , vol.41 , Issue.9 , pp. 2490-2495
    • Danielsson, O.1    Leijon, M.2    Sjostedt, E.3
  • 28
    • 28844452904 scopus 로고    scopus 로고
    • Time stepping finite element analysis of a variable speed synchronous generator with rectifier
    • Thorburn K., Karlsson K.-E., Wolfbrandt A., Eriksson M. Time stepping finite element analysis of a variable speed synchronous generator with rectifier. Appl Energy 2006, 83(4):371-386.
    • (2006) Appl Energy , vol.83 , Issue.4 , pp. 371-386
    • Thorburn, K.1    Karlsson, K.-E.2    Wolfbrandt, A.3    Eriksson, M.4
  • 29
    • 77953306247 scopus 로고    scopus 로고
    • Maximum-power-point tracking with reduced mechanical stress applied to wind-energy-conversion-systems
    • González L.G., Figueres E., Garcerá G., Carranza O. Maximum-power-point tracking with reduced mechanical stress applied to wind-energy-conversion-systems. Appl Energy 2010, 87(7):2304-2312.
    • (2010) Appl Energy , vol.87 , Issue.7 , pp. 2304-2312
    • González, L.G.1    Figueres, E.2    Garcerá, G.3    Carranza, O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.