메뉴 건너뛰기




Volumn 38, Issue 4, 2010, Pages 414-419

Slower progression of atherosclerosis in vein grafts harvested with 'no touch' technique compared with conventional harvesting technique in coronary artery bypass grafting: An angiographic and intravascular ultrasound study

Author keywords

CABG; Coronary artery bypass grafts; Ischaemic heart disease; IVUS; Revascularisation

Indexed keywords

AGED; ARTERY INTIMA PROLIFERATION; ARTICLE; ATHEROSCLEROSIS; ATHEROSCLEROTIC PLAQUE; CINEANGIOCARDIOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; DISEASE COURSE; FEMALE; FOLLOW UP; HUMAN; INTRAVASCULAR ULTRASOUND; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SURGICAL TECHNIQUE; VEIN GRAFT;

EID: 77957287723     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2010.02.007     Document Type: Article
Times cited : (72)

References (25)
  • 1
    • 0019441505 scopus 로고
    • Changes in venous endothelial fibrinolytic activity and histology with in vitro venous distention and arterial implantation
    • Malone J.M., Kischer C.W., Moore W.S. Changes in venous endothelial fibrinolytic activity and histology with in vitro venous distention and arterial implantation. Am J Surg 1981, 142(2):178-182.
    • (1981) Am J Surg , vol.142 , Issue.2 , pp. 178-182
    • Malone, J.M.1    Kischer, C.W.2    Moore, W.S.3
  • 2
    • 0021702087 scopus 로고
    • Optimal techniques for harvesting and preparation of reversed autogenous vein grafts for use as arterial substitutes: a review
    • Adcock O.T., Adcock G.L., Wheeler J.R., Gregory R.T., Snyder S.O., Gayle R.G. Optimal techniques for harvesting and preparation of reversed autogenous vein grafts for use as arterial substitutes: a review. Surgery 1984, 96(5):886-894.
    • (1984) Surgery , vol.96 , Issue.5 , pp. 886-894
    • Adcock, O.T.1    Adcock, G.L.2    Wheeler, J.R.3    Gregory, R.T.4    Snyder, S.O.5    Gayle, R.G.6
  • 3
    • 85047676699 scopus 로고
    • Nature and pressure dependence of damage induced by distension of human saphenous vein coronary artery bypass grafts
    • Angelini G.D., Passani S.L., Breckenridge I.M., Newby A.C. Nature and pressure dependence of damage induced by distension of human saphenous vein coronary artery bypass grafts. Cardiovasc Res 1987, 21(12):902-907.
    • (1987) Cardiovasc Res , vol.21 , Issue.12 , pp. 902-907
    • Angelini, G.D.1    Passani, S.L.2    Breckenridge, I.M.3    Newby, A.C.4
  • 4
    • 0027995533 scopus 로고
    • Long-term vein graft patency
    • Bourassa M.G. Long-term vein graft patency. Curr Opin Cardiol 1994, 9(6):685-691.
    • (1994) Curr Opin Cardiol , vol.9 , Issue.6 , pp. 685-691
    • Bourassa, M.G.1
  • 6
    • 0015449232 scopus 로고
    • Changes in vein grafts following aorto-coronary bypass induced by pressure and ischemia
    • Brody W.R., Kosek J.C., Angell W.W. Changes in vein grafts following aorto-coronary bypass induced by pressure and ischemia. J Thorac Cardiovasc Surg 1972, 64(6):847-854.
    • (1972) J Thorac Cardiovasc Surg , vol.64 , Issue.6 , pp. 847-854
    • Brody, W.R.1    Kosek, J.C.2    Angell, W.W.3
  • 7
    • 0032754227 scopus 로고    scopus 로고
    • "No-touch" technique using saphenous vein harvested with its surrounding tissue for coronary artery bypass grafting maintains an intact endothelium
    • Souza D.S., Christofferson R.H., Bomfim V., Filbey D. "No-touch" technique using saphenous vein harvested with its surrounding tissue for coronary artery bypass grafting maintains an intact endothelium. Scand Cardiovasc J 1999, 33(6):323-329.
    • (1999) Scand Cardiovasc J , vol.33 , Issue.6 , pp. 323-329
    • Souza, D.S.1    Christofferson, R.H.2    Bomfim, V.3    Filbey, D.4
  • 8
    • 0029981806 scopus 로고    scopus 로고
    • A new no-touch preparation technique. Technical notes
    • Souza D. A new no-touch preparation technique. Technical notes. Scand J Thorac Cardiovasc Surg 1996, 30(1):41-44.
    • (1996) Scand J Thorac Cardiovasc Surg , vol.30 , Issue.1 , pp. 41-44
    • Souza, D.1
  • 9
    • 1842507139 scopus 로고    scopus 로고
    • Human saphenous vein and coronary bypass surgery: ultrastructural aspects of conventional and "no-touch" vein graft preparations
    • Ahmed S.R., Johansson B.L., Karlsson M.G., Souza D.S., Dashwood M.R., Loesch A. Human saphenous vein and coronary bypass surgery: ultrastructural aspects of conventional and "no-touch" vein graft preparations. Histol Histopathol 2004, 19(2):421-433.
    • (2004) Histol Histopathol , vol.19 , Issue.2 , pp. 421-433
    • Ahmed, S.R.1    Johansson, B.L.2    Karlsson, M.G.3    Souza, D.S.4    Dashwood, M.R.5    Loesch, A.6
  • 10
    • 0036208590 scopus 로고    scopus 로고
    • Improved patency in vein grafts harvested with surrounding tissue: results of a randomized study using three harvesting techniques
    • Souza D.S., Dashwood M.R., Tsui J.C., Filbey D., Bodin L., Johansson B., Borowiec J. Improved patency in vein grafts harvested with surrounding tissue: results of a randomized study using three harvesting techniques. Ann Thorac Surg 2002, 73(4):1189-1195.
    • (2002) Ann Thorac Surg , vol.73 , Issue.4 , pp. 1189-1195
    • Souza, D.S.1    Dashwood, M.R.2    Tsui, J.C.3    Filbey, D.4    Bodin, L.5    Johansson, B.6    Borowiec, J.7
  • 11
    • 33746228346 scopus 로고    scopus 로고
    • Harvesting the saphenous vein with surrounding tissue for CABG provides long-term graft patency comparable to the left internal thoracic artery: results of a randomized longitudinal trial
    • Souza D.S., Johansson B., Bojo L., Karlsson R., Geijer H., Filbey D., Bodin L., Arbeus M., Dashwood M.R. Harvesting the saphenous vein with surrounding tissue for CABG provides long-term graft patency comparable to the left internal thoracic artery: results of a randomized longitudinal trial. J Thorac Cardiovasc Surg 2006, 132(2):373-378.
    • (2006) J Thorac Cardiovasc Surg , vol.132 , Issue.2 , pp. 373-378
    • Souza, D.S.1    Johansson, B.2    Bojo, L.3    Karlsson, R.4    Geijer, H.5    Filbey, D.6    Bodin, L.7    Arbeus, M.8    Dashwood, M.R.9
  • 12
    • 61649099880 scopus 로고    scopus 로고
    • No touch vein harvesting technique for CABG improves the long-term clinical outcome
    • Johansson B.L., Souza D.S., Bodin L., Filbey D., Bojo L. No touch vein harvesting technique for CABG improves the long-term clinical outcome. Scand Cardiovasc J 2009, 43(1):63-68.
    • (2009) Scand Cardiovasc J , vol.43 , Issue.1 , pp. 63-68
    • Johansson, B.L.1    Souza, D.S.2    Bodin, L.3    Filbey, D.4    Bojo, L.5
  • 13
    • 0014147066 scopus 로고
    • Selective coronary arterography. Part I: a percutaneous transfemoral technique
    • Judkins M.P. Selective coronary arterography. Part I: a percutaneous transfemoral technique. Radiology 1967, 89:815-824.
    • (1967) Radiology , vol.89 , pp. 815-824
    • Judkins, M.P.1
  • 14
    • 0035133978 scopus 로고    scopus 로고
    • Direct measurement of nitric oxide release from saphenous vein: abolishment by surgical preparation
    • Liu Z.G., Liu X.C., Yim A.P., He G.W. Direct measurement of nitric oxide release from saphenous vein: abolishment by surgical preparation. Ann Thorac Surg 2001, 71(1):133-137.
    • (2001) Ann Thorac Surg , vol.71 , Issue.1 , pp. 133-137
    • Liu, Z.G.1    Liu, X.C.2    Yim, A.P.3    He, G.W.4
  • 15
    • 0035672442 scopus 로고    scopus 로고
    • Preserved endothelial integrity and nitric oxide synthase in saphenous vein grafts harvested by a 'no-touch' technique
    • Tsui J.C., Souza D.S., Filbey D., Bomfim V., Dashwood M.R. Preserved endothelial integrity and nitric oxide synthase in saphenous vein grafts harvested by a 'no-touch' technique. Br J Surg 2001, 88(9):1209-1215.
    • (2001) Br J Surg , vol.88 , Issue.9 , pp. 1209-1215
    • Tsui, J.C.1    Souza, D.S.2    Filbey, D.3    Bomfim, V.4    Dashwood, M.R.5
  • 16
    • 0036482335 scopus 로고    scopus 로고
    • Localization of nitric oxide synthase in saphenous vein grafts harvested with a novel "no-touch" technique: potential role of nitric oxide contribution to improved early graft patency rates
    • Tsui J.C., Souza D.S., Filbey D., Karlsson M.G., Dashwood M.R. Localization of nitric oxide synthase in saphenous vein grafts harvested with a novel "no-touch" technique: potential role of nitric oxide contribution to improved early graft patency rates. J Vasc Surg 2002, 35(2):356-362.
    • (2002) J Vasc Surg , vol.35 , Issue.2 , pp. 356-362
    • Tsui, J.C.1    Souza, D.S.2    Filbey, D.3    Karlsson, M.G.4    Dashwood, M.R.5
  • 17
    • 0036969731 scopus 로고    scopus 로고
    • Postoperative changes in angiographically normal saphenous vein coronary bypass grafts using intravascular ultrasound
    • Higuchi Y., Hirayama A., Shimizu M., Sakakibara T., Kodama K. Postoperative changes in angiographically normal saphenous vein coronary bypass grafts using intravascular ultrasound. Heart Vessels 2002, 17(2):57-60.
    • (2002) Heart Vessels , vol.17 , Issue.2 , pp. 57-60
    • Higuchi, Y.1    Hirayama, A.2    Shimizu, M.3    Sakakibara, T.4    Kodama, K.5
  • 18
    • 0029913938 scopus 로고    scopus 로고
    • Use of intravascular ultrasound for in vivo assessment of changes in intimal thickness of angiographically normal saphenous vein grafts one year after aortocoronary bypass surgery
    • Hozumi T., Yoshikawa J., Yoshida K., Akasaka T., Takagi T., Honda Y., Okura H. Use of intravascular ultrasound for in vivo assessment of changes in intimal thickness of angiographically normal saphenous vein grafts one year after aortocoronary bypass surgery. Heart 1996, 76(4):317-320.
    • (1996) Heart , vol.76 , Issue.4 , pp. 317-320
    • Hozumi, T.1    Yoshikawa, J.2    Yoshida, K.3    Akasaka, T.4    Takagi, T.5    Honda, Y.6    Okura, H.7
  • 19
    • 0029757671 scopus 로고    scopus 로고
    • External stenting reduces early medial and neointimal thickening in a pig model of arteriovenous bypass grafting
    • Angelini G.D., Izzat M.B., Bryan A.J., Newby A.C. External stenting reduces early medial and neointimal thickening in a pig model of arteriovenous bypass grafting. J Thorac Cardiovasc Surg 1996, 112(1):79-84.
    • (1996) J Thorac Cardiovasc Surg , vol.112 , Issue.1 , pp. 79-84
    • Angelini, G.D.1    Izzat, M.B.2    Bryan, A.J.3    Newby, A.C.4
  • 20
    • 0029783846 scopus 로고    scopus 로고
    • Influence of external stent size on early medial and neointimal thickening in a pig model of saphenous vein bypass grafting
    • Izzat M.B., Mehta D., Bryan A.J., Reeves B., Newby A.C., Angelini G.D. Influence of external stent size on early medial and neointimal thickening in a pig model of saphenous vein bypass grafting. Circulation 1996, 94(7):1741-1745.
    • (1996) Circulation , vol.94 , Issue.7 , pp. 1741-1745
    • Izzat, M.B.1    Mehta, D.2    Bryan, A.J.3    Reeves, B.4    Newby, A.C.5    Angelini, G.D.6
  • 21
    • 0031045178 scopus 로고    scopus 로고
    • Nitric oxide synthase and adenylyl and guanylyl cyclase activity in porcine interposition vein grafts
    • Jeremy J.Y., Dashwood M.R., Timm M., Izzat M.B., Mehta D., Bryan A.J., Angelini G.D. Nitric oxide synthase and adenylyl and guanylyl cyclase activity in porcine interposition vein grafts. Ann Thorac Surg 1997, 63(2):470-476.
    • (1997) Ann Thorac Surg , vol.63 , Issue.2 , pp. 470-476
    • Jeremy, J.Y.1    Dashwood, M.R.2    Timm, M.3    Izzat, M.B.4    Mehta, D.5    Bryan, A.J.6    Angelini, G.D.7
  • 22
    • 0024365610 scopus 로고
    • Rapidly progressive atherosclerosis in aortocoronary saphenous vein grafts. Possible immune-mediated disease
    • Ratliff N.B., Myles J.L. Rapidly progressive atherosclerosis in aortocoronary saphenous vein grafts. Possible immune-mediated disease. Arch Pathol Lab Med 1989, 113(7):772-776.
    • (1989) Arch Pathol Lab Med , vol.113 , Issue.7 , pp. 772-776
    • Ratliff, N.B.1    Myles, J.L.2
  • 23
    • 0036754582 scopus 로고    scopus 로고
    • Understanding and treating vein graft atherosclerosis
    • Sarjeant J.M., Rabinovitch M. Understanding and treating vein graft atherosclerosis. Cardiovasc Pathol 2002, 11(5):263-271.
    • (2002) Cardiovasc Pathol , vol.11 , Issue.5 , pp. 263-271
    • Sarjeant, J.M.1    Rabinovitch, M.2
  • 25
    • 58549098524 scopus 로고    scopus 로고
    • Impact of vascular remodeling on the coronary plaque compositions: an investigation with in vivo tissue characterization using integrated backscatter-intravascular ultrasound
    • Takeuchi H., Morino Y., Matsukage T., Masuda N., Kawamura Y., Kasai S., Hashida T., Fujibayashi D., Tanabe T., Ikari Y. Impact of vascular remodeling on the coronary plaque compositions: an investigation with in vivo tissue characterization using integrated backscatter-intravascular ultrasound. Atherosclerosis 2009, 202(2):476-482.
    • (2009) Atherosclerosis , vol.202 , Issue.2 , pp. 476-482
    • Takeuchi, H.1    Morino, Y.2    Matsukage, T.3    Masuda, N.4    Kawamura, Y.5    Kasai, S.6    Hashida, T.7    Fujibayashi, D.8    Tanabe, T.9    Ikari, Y.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.