메뉴 건너뛰기




Volumn 6, Issue 1, 2010, Pages 149-160

Safety and efficacy of drug-eluting stents versus bare-metal stents in saphenous vein grafts lesions: A meta-analysis

Author keywords

Bare metal stent; Coronary artery bypass graft; Drug eluting stent; Saphenous vein graft

Indexed keywords

AGED; ARTICLE; BARE METAL STENT; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; DRUG ELUTING STENT; HEART INFARCTION; HEART MUSCLE REVASCULARIZATION; HUMAN; MAJOR CLINICAL STUDY; META ANALYSIS; MORTALITY; OUTCOME ASSESSMENT; PATIENT SAFETY; RANDOMIZED CONTROLLED TRIAL; RISK ASSESSMENT; RISK REDUCTION; SAPHENOUS VEIN GRAFT; STENT THROMBOSIS; SYSTEMATIC REVIEW; VEIN GRAFT DISEASE; CORONARY ARTERY BYPASS GRAFT; GRAFT OCCLUSION; INSTRUMENTATION; MIDDLE AGED; PROSTHESIS; REVIEW; RISK; RISK FACTOR; SAPHENOUS VEIN; STENT; THROMBOSIS; TRANSLUMINAL CORONARY ANGIOPLASTY; TRANSPLANTATION; TREATMENT OUTCOME;

EID: 77957286794     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV6I1A22     Document Type: Article
Times cited : (34)

References (32)
  • 2
    • 45849084649 scopus 로고    scopus 로고
    • Drug-eluting stent in saphenous vein graft lesions
    • DOI 10.1002/ccd.21615
    • Kornowski R. Drug-eluting stent in saphenous vein graft lesions. Catheter Cardiovasc Interv 2008;71:894-895. (Pubitemid 351951306)
    • (2008) Catheterization and Cardiovascular Interventions , vol.71 , Issue.7 , pp. 894-895
    • Kornowski, R.1
  • 5
    • 34848856445 scopus 로고    scopus 로고
    • Utility of sirolimus-eluting Cypher stents to reduce 12-month target vessel revascularization in saphenous vein graft stenoses: Results of a multicenter 350-patient case-control study
    • Ellis SG, Kandzari D, Kereiakes DJ, Pichard A, Huber K, Resnic F, Yakubov S, Callahan K, Borgman M, Cohen SA. Utility of sirolimus-eluting Cypher stents to reduce 12-month target vessel revascularization in saphenous vein graft stenoses: results of a multicenter 350-patient case-control study. J Invasive Cardiol 2007;19:404-409. (Pubitemid 47509462)
    • (2007) Journal of Invasive Cardiology , vol.19 , Issue.10 , pp. 404-409
    • Ellis, S.G.1    Kandzari, D.2    Kereiakes, D.J.3    Pichard, A.4    Huber, K.5    Resnic, F.6    Yakubov, S.7    Callahan, K.8    Borgman, M.9    Cohen, S.A.10
  • 7
    • 34147197569 scopus 로고    scopus 로고
    • Implantation of paclitaxel-eluting stents in saphenous vein grafts: Clinical and angiographic follow-up results from a multicentre study
    • DOI 10.1136/hrt.2006.094722
    • Hoffmann R, Pohl T, Koster R, Blindt R, Boeckstegers P, Heitzer T. Implantation of paclitaxel-eluting stents in saphenous vein grafts: clinical and angiographic follow-up results from a multicentre study. Heart 2007;93:331-334. (Pubitemid 46579523)
    • (2007) Heart , vol.93 , Issue.3 , pp. 331-334
    • Hoffmann, R.1    Pohl, T.2    Koster, R.3    Blindt, R.4    Boeckstegers, P.5    Heitzer, T.6
  • 8
    • 45849134854 scopus 로고    scopus 로고
    • Immediate procedural and long-term clinical outcomes following drug-eluting stent implantation to ostial saphenous vein graft lesions
    • DOI 10.1080/17482940701885400, PII 793648339
    • Kaplan S, Barlis P, Kiris A, Dimopoulos K, Celik S, Di Mario C. Immediate procedural and long-term clinical outcomes following drugeluting stent implantation to ostial saphenous vein graft lesions. Acute Card Care 2008;10:88-92. (Pubitemid 351883440)
    • (2008) Acute Cardiac Care , vol.10 , Issue.2 , pp. 88-92
    • Kaplan, S.1    Barlis, P.2    Kiris, A.3    Dimopoulos, K.4    Celik, S.5    Di, M.C.6
  • 10
    • 33845410666 scopus 로고    scopus 로고
    • Randomized Double-Blind Comparison of Sirolimus-Eluting Stent Versus Bare-Metal Stent Implantation in Diseased Saphenous Vein Grafts. Six-Month Angiographic, Intravascular Ultrasound, and Clinical Follow-Up of the RRISC Trial
    • DOI 10.1016/j.jacc.2006.09.021, PII S0735109706024491
    • Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, Bruining N, Van den Branden F, Van Langenhove G. Randomized doubleblind comparison of sirolimus-eluting stent versus bare-metal stent implantation in diseased saphenous vein grafts: six-month angiographic, intravascular ultrasound, and clinical follow-up of the RRISC Trial. J Am Coll Cardiol 2006;48:2423-2431. (Pubitemid 44895571)
    • (2006) Journal of the American College of Cardiology , vol.48 , Issue.12 , pp. 2423-2431
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    Van Den, H.P.4    Convens, C.5    Bruining, N.6    Van Den, B.F.7    Van Langenhove, G.8
  • 12
    • 33846927284 scopus 로고    scopus 로고
    • Comparison of the slow-release polymerbased paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions
    • DOI 10.1007/s00392-006-0460-1
    • Wohrle J, Nusser T, Kestler HA, Kochs M, Hombach V. Comparison of the slow-release polymer-based paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions. Clin Res Cardiol 2007;96:70-76. (Pubitemid 46233208)
    • (2007) Clinical Research in Cardiology , vol.96 , Issue.2 , pp. 70-76
    • Wohrle, J.1    Nusser, T.2    Kestler, H.A.3    Kochs, M.4    Hombach, V.5
  • 13
    • 34447120247 scopus 로고    scopus 로고
    • Increased Late Mortality after Sirolimus-Eluting Stents Versus Bare-Metal Stents in Diseased Saphenous Vein Grafts. Results from the Randomized DELAYED RRISC Trial
    • DOI 10.1016/j.jacc.2007.05.010, PII S0735109707016658
    • Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, Van den Branden F, Van Langenhove G; DELAYED RRISC (Death and Events at Long-term follow-up AnalYsis: Extended Duration of the Reduction of Restenosis In Saphenous vein grafts with Cypher stent) Investigators Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts: results from the randomized DELAYED RRISC Trial. J Am Coll Cardiol 2007;50:261-267. (Pubitemid 47039289)
    • (2007) Journal of the American College of Cardiology , vol.50 , Issue.3 , pp. 261-267
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    Van Den, H.P.4    Convens, C.5    Van Den, B.F.6    Van Langenhove, G.7
  • 14
    • 47549096848 scopus 로고    scopus 로고
    • Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts
    • Gioia G, Benassi A, Mohendra R, Chowdhury K, Masood I, MatthaiW. Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts. Catheter Cardiovasc Interv 2008;72:13-20.
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 13-20
    • Gioia, G.1    Benassi, A.2    Mohendra, R.3    Chowdhury, K.4    Masood, I.5    Matthai, W.6
  • 15
    • 74249090627 scopus 로고    scopus 로고
    • Long-term outcomes of drug-eluting stents versus bare-metal stents in saphenous vein graft disease: Results from the Prairie "Real World" Stent Registry
    • Goswami NJ, Gaffigan M, Berrio G, Plessa AL, Pfeiffer AM, Markwell SJ, Mishkel GJ. Long-term outcomes of drug-eluting stents versus bare-metal stents in saphenous vein graft disease: results From the Prairie "Real World" Stent Registry. Catheter Cardiovasc Interv 2010;75:93-100.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 93-100
    • Goswami, N.J.1    Gaffigan, M.2    Berrio, G.3    Plessa, A.L.4    Pfeiffer, A.M.5    Markwell, S.J.6    Mishkel, G.J.7
  • 18
    • 59049086905 scopus 로고    scopus 로고
    • Four-year safety and efficacy of the unrestricted use of sirolimus- And paclitaxel-eluting stents in coronary artery bypass grafts
    • van Twisk PH, Daemen J, Kukreja N, van Domburg RT, Serruys PW. Four-year safety and efficacy of the unrestricted use of sirolimus- and paclitaxel-eluting stents in coronary artery bypass grafts. EuroIntervention 2008;4:311-317.
    • (2008) EuroIntervention , vol.4 , pp. 311-317
    • Van Twisk, P.H.1    Daemen, J.2    Kukreja, N.3    Van Domburg, R.T.4    Serruys, P.W.5
  • 21
    • 0037098199 scopus 로고    scopus 로고
    • Quantifying heterogeneity in a metaanalysis
    • Higgins JP, Thompson SG. Quantifying heterogeneity in a metaanalysis. Stat Med 2002;21:1539-1558.
    • (2002) Stat Med , vol.21 , pp. 1539-1558
    • Higgins, J.P.1    Thompson, S.G.2
  • 27
    • 57049165763 scopus 로고    scopus 로고
    • Drug-eluting stents compared with bare metal stents improve late outcome after saphenous vein graft but not after large native vessel interventions
    • BASKET Investigators.
    • Jeger RV, Schneiter S, Kaiser C, Bonetti PO, Brunner-La Rocca H, Handke M, Osswald S, Buser PT, Pfisterer ME; BASKET Investigators. Drug-eluting stents compared with bare metal stents improve late outcome after saphenous vein graft but not after large native vessel interventions. Cardiology 2009;112:49-55.
    • (2009) Cardiology , vol.112 , pp. 49-55
    • Jeger, R.V.1    Schneiter, S.2    Kaiser, C.3    Bonetti, P.O.4    Brunner-La Rocca, H.5    Handke, M.6    Osswald, S.7    Buser, P.T.8    Pfisterer, M.E.9
  • 28
    • 36549008097 scopus 로고    scopus 로고
    • Long-term clinical benefit of sirolimus-eluting stents compared to bare metal stents in the treatment of saphenous vein graft disease
    • DOI 10.1111/j.1540-8183.2007.00301.x
    • Minutello RM, Bhagan S, Sharma A, Slotwiner AJ, Feldman DN, Cuomo LJ, Wong SC. Long-term clinical benefit of sirolimus-eluting stents compared to bare metal stents in the treatment of saphenous vein graft disease. J Interv Cardiol 2007;20:458-465. (Pubitemid 350179467)
    • (2007) Journal of Interventional Cardiology , vol.20 , Issue.6 , pp. 458-465
    • Minutello, R.M.1    Bhagan, S.2    Sharma, A.3    Slotwiner, A.J.4    Feldman, D.N.5    Cuomo, L.J.6    Wong, S.C.7
  • 31
    • 0037133682 scopus 로고    scopus 로고
    • Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
    • Saphenous vein graft Angioplasty Free of Emboli Randomized (SAFER) Trial Investigators.
    • Baim DS, Wahr D, George B, Leon MB, Greenberg J, Cutlip DE, Kaya U, Popma JJ, Ho KK, Kuntz RE; Saphenous vein graft Angioplasty Free of Emboli Randomized (SAFER) Trial Investigators. Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts. Circulation 2002;105:1285-1290.
    • (2002) Circulation , vol.105 , pp. 1285-1290
    • Baim, D.S.1    Wahr, D.2    George, B.3    Leon, M.B.4    Greenberg, J.5    Cutlip, D.E.6    Kaya, U.7    Popma, J.J.8    Ho, K.K.9    Kuntz, R.E.10
  • 32
    • 34250812581 scopus 로고    scopus 로고
    • Intravascular Ultrasound Comparison of Sirolimus-Eluting Stent Versus Bare Metal Stent Implantation in Diseased Saphenous Vein Grafts (from the RRISC [Reduction of Restenosis in Saphenous Vein Grafts with Cypher Sirolimus-Eluting Stent] Trial)
    • DOI 10.1016/j.amjcard.2007.02.052, PII S0002914907005693
    • Agostoni P, Vermeersch P, Semeraro O, Verheye S, Van Langenhove G, Van den Heuvel P, Convens C, Van den Branden F, Bruining N Intravascular ultrasound comparison of sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts (from the RRISC [Reduction of Restenosis In Saphenous Vein Grafts With Cypher Sirolimus-Eluting Stent] trial). Am J Cardiol 2007;100:52-58. (Pubitemid 46970699)
    • (2007) American Journal of Cardiology , vol.100 , Issue.1 , pp. 52-58
    • Agostoni, P.1    Vermeersch, P.2    Semeraro, O.3    Verheye, S.4    Van Langenhove, G.5    Van Den, H.P.6    Convens, C.7    Van Den, B.F.8    Bruining, N.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.