메뉴 건너뛰기




Volumn 34, Issue 9, 2010, Pages 707-713

The aachen MiniHLM - A miniaturized heart-lung machine for neonates with an integrated rotary blood pump

Author keywords

Heart Lung machine; Neonates; Oxygenation; Perfusion; Priming volume; Rotary blood pump

Indexed keywords

ARTIFICIAL HEART; BIOLOGICAL ORGANS; BLOOD; HEART; PUMPS; TUBING; VALVES (MECHANICAL);

EID: 77957269711     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01082.x     Document Type: Article
Times cited : (21)

References (13)
  • 3
    • 0028900625 scopus 로고
    • The pathophysiology of cardiopulmonary bypass. The risks and benefits of hemodilution
    • Hall TS. The pathophysiology of cardiopulmonary bypass. The risks and benefits of hemodilution. Chest 1995 107 : 1125 133.
    • (1995) Chest , vol.107 , pp. 1125-1133
    • Hall, T.S.1
  • 4
    • 33646831623 scopus 로고    scopus 로고
    • Effects of Circuit Miniaturization in Reducing Inflammatory Response to Infant Cardiopulmonary Bypass by Elimination of Allogeneic Blood Products
    • DOI 10.1016/j.athoracsur.2006.02.071, PII S0003497506004139
    • Hickey E, Karamlou T, You J, Ungerleider RM. Effects of circuit miniaturization in reducing inflammatory response to infant cardiopulmonary bypass by elimination of allogeneic blood products. Ann Thorac Surg 2006 81 : S2367 72. (Pubitemid 43775526)
    • (2006) Annals of Thoracic Surgery , vol.81 , Issue.6
    • Hickey, E.1    Karamlou, T.2    You, J.3    Ungerleider, R.M.4
  • 5
    • 4444226266 scopus 로고    scopus 로고
    • Compact intra- and extracorporeal oxygenator developments
    • DOI 10.1191/0267659104pf748oa
    • Cattaneo G, Strauss A, Reul H. Compact intra- and extracorporeal oxygenator developments. Perfusion 2004 19 : 251 5. (Pubitemid 39173457)
    • (2004) Perfusion , vol.19 , Issue.4 , pp. 251-255
    • Gattaneo, G.1    Strauss, A.2    Reul, H.3
  • 8
    • 77957261233 scopus 로고    scopus 로고
    • DIN EN 12022:1999. DIN Deutsches Institut für Normung e.V., Mar
    • DIN EN 12022:1999. Blutgasaustauscher. DIN Deutsches Institut für Normung e.V., Mar 1999.
    • (1999) Blutgasaustauscher
  • 9
    • 36749032878 scopus 로고    scopus 로고
    • Final Guidance for Industry and FDA Staff. Rockville, MD: Food and Drug Administration. Available at:. Accessed July 22, 2010.
    • Guidance for Cardiopulmonary Bypass Oxygenators 510(k) Submissions; Final Guidance for Industry and FDA Staff. Rockville, MD: Food and Drug Administration. Available at: http://www.fda.gov/MedicalDevices/. Accessed July 22, 2010.
    • Guidance for Cardiopulmonary Bypass Oxygenators 510(k) Submissions
  • 11
    • 0032170917 scopus 로고    scopus 로고
    • Species differences in erythrocyte mechanical fragility: Comparison of human, bovine, and ovine cells
    • Jikuya T, Tsutsui T, Shigeta O, Sankai Y, Mitsui T. Species differences in erythrocyte mechanical fragility: comparison of human, bovine, and ovine cells. ASAIO J 1998 44 : M452 5. (Pubitemid 28468875)
    • (1998) ASAIO Journal , vol.44 , Issue.5
    • Jikuya, T.1    Tsutsui, T.2    Shigeta, O.3    Sankai, Y.4    Mitsui, T.5
  • 12
    • 70450280523 scopus 로고    scopus 로고
    • The Aachen miniaturized heart-lung machine - First results in a small animal model
    • Schnoering H, Arens J, Sachweh JS, et al. The Aachen miniaturized heart-lung machine - first results in a small animal model. Artif Organs 2009 33 : 935 40.
    • (2009) Artif Organs , vol.33 , pp. 935-940
    • Schnoering, H.1    Arens, J.2    Sachweh, J.S.3
  • 13
    • 0036197495 scopus 로고    scopus 로고
    • Vacuum-assisted venous drainage: To air or not to air, that is the question. Has the bubble burst?
    • Willcox TW. Vacuum-assisted venous drainage: to air or not to air, that is the question. Has the bubble burst? J Extra Corpor Technol 2002 34 : 24 8.
    • (2002) J Extra Corpor Technol , vol.34 , pp. 24-28
    • Willcox, T.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.