-
1
-
-
0030926834
-
Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump
-
Yamada T, Nishimura K, Akamatsu T, et al. In vivo testing of a magnetically suspended centrifugal pump designed for long-term use. Int J Artif Organs 1997 20 : 562 9. (Pubitemid 27238858)
-
(1997)
Artificial Organs
, vol.21
, Issue.5
, pp. 396-401
-
-
Tsukiya, T.1
Akamatsu, T.2
Nishimura, K.3
Yamada, T.4
Nakazeki, T.5
-
2
-
-
0016412524
-
Response of human platelets to shear stress
-
Brown CH III., Lemuth RF, Hellums JD, Leverett LB, Alfrey CP. Response of human platelets to shear stress. ASAIO J 1975 21 : 35 9.
-
(1975)
ASAIO J
, vol.21
, pp. 35-39
-
-
Brown III, C.H.1
Lemuth, R.F.2
Hellums, J.D.3
Leverett, L.B.4
Alfrey, C.P.5
-
3
-
-
0029916176
-
A quantitative visualization study of flow in a scaled-up model of a centrifugal blood pump
-
Ikeda T, Yamane T, Orita T, Tateishi T. A quantitative visualization study of flow in a scaled-up model of a centrifugal blood pump. Artif Organs 1996 20 : 132 8. (Pubitemid 26132607)
-
(1996)
Artificial Organs
, vol.20
, Issue.2
, pp. 132-138
-
-
Ikeda, T.1
Yamane, T.2
Orita, T.3
Tateishi, T.4
-
4
-
-
0030946449
-
Flow rate measurement for the Magnetically Suspended Centrifugal Blood Pump
-
Yamada T, Tsukiya T, Akamatsu T, Kono S, Yamada T, Ban T. Chronic animal experiment with magnetically suspended centrifugal pump. Artif Organs 1997 21 : 635 8. (Pubitemid 27136560)
-
(1997)
Japanese Journal of Artificial Organs
, vol.26
, Issue.1
, pp. 98-102
-
-
Tsukiya, T.1
Akamatsu, T.2
Nishimura, K.3
-
5
-
-
26444519934
-
Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics-based design optimization
-
DOI 10.1097/01.mat.0000178966.79876.3d
-
Wu J, Antaki JF, Wagner WR, Snyder TA, Paden BE, Borovetz HS. Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics-based design optimization. ASAIO J 2005 51 : 636 43. (Pubitemid 41434253)
-
(2005)
ASAIO Journal
, vol.51
, Issue.5
, pp. 636-643
-
-
Wu, J.1
Antaki, J.F.2
Wagner, W.R.3
Snyder, T.A.4
Paden, B.E.5
Borovetz, H.S.6
-
6
-
-
0033803536
-
Analytical investigation of leakage flow in disk clearance of a magnetically suspended centrifugal impeller
-
Chan WK, Akamatsu T, Li HD. Analytical investigation of leakage flow in disk clearance of a magnetically suspended centrifugal impeller. Artif Organs 2000 24 : 734 42.
-
(2000)
Artif Organs
, vol.24
, pp. 734-742
-
-
Chan, W.K.1
Akamatsu, T.2
Li, H.D.3
-
7
-
-
0034940556
-
Particle image velocimetry measurements of blood velocity in a continuous flow ventricular assist device
-
Day SW, McDaniel JC, Wood HG, Allaire PE, Landrot N, Curtas A. Particle image velocimetry measurements of blood velocity in a continuous flow ventricular assist device. ASAIO J 2001 47 : 406 11. (Pubitemid 32655816)
-
(2001)
ASAIO Journal
, vol.47
, Issue.4
, pp. 406-411
-
-
Day, S.W.1
McDaniel, J.C.2
Wood, H.G.3
Allaire, P.E.4
Landrot, N.5
Curtas, A.6
-
8
-
-
0033918274
-
Numerical analysis of blood flow in the clearance regions of a continuous flow artificial heart pump
-
DOI 10.1046/j.1525-1594.2000.06580.x
-
Anderson J, Wood HG, Allaire PE, Olsen DB. Numerical analysis of blood flow in the clearance regions of a continuous flow artificial heart pump. Artif Organs 2000 24 : 492 500. (Pubitemid 30430514)
-
(2000)
Artificial Organs
, vol.24
, Issue.6
, pp. 492-500
-
-
Anderson, J.1
Wood, H.G.2
Allaire, P.E.3
Olsen, D.B.4
-
9
-
-
33646236822
-
A review of leakage flow in centrifugal blood pumps
-
Chan WK, Wong YW. A review of leakage flow in centrifugal blood pumps. Artif Organs 2006 30 : 354 9.
-
(2006)
Artif Organs
, vol.30
, pp. 354-359
-
-
Chan, W.K.1
Wong, Y.W.2
-
10
-
-
27844445708
-
Hydrodynamic design and performance analysis of a centrifugal blood pump for cardiopulmonary circulation
-
Oh HW, Suzuki M, Hoshi H, Ohuchi K, Fujimoto T, Takatani S. Hydrodynamic design and performance analysis of a centrifugal blood pump for cardiopulmonary circulation. Proc Inst Mech Eng A J Power Energy 2005 219 : 525 32.
-
(2005)
Proc Inst Mech Eng A J Power Energy
, vol.219
, pp. 525-532
-
-
Oh, H.W.1
Suzuki, M.2
Hoshi, H.3
Ohuchi, K.4
Fujimoto, T.5
Takatani, S.6
-
11
-
-
41149145906
-
Computational fluid dynamics investigation of a centrifugal blood pump
-
DOI 10.1111/j.1525-1594.2008.00552.x
-
Legendre D, Antunes P, Bock E, Andrade A, Biscegli JF, Ortiz JP. Computational fluid dynamics investigation of a centrifugal blood pump. Artif Organs 2008 32 : 342 8. (Pubitemid 351442648)
-
(2008)
Artificial Organs
, vol.32
, Issue.4
, pp. 342-348
-
-
Legendre, D.1
Antunes, P.2
Bock, E.3
Andrade, A.4
Biscegli, J.F.5
Ortiz, J.P.6
-
12
-
-
33644993283
-
Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump
-
Zhang J, Gellman B, Koert A, Dasse KA, Gilbert RJ, Griffith BP, Wu ZJ. Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump. Artif Organs 2006 30 : 168 77.
-
(2006)
Artif Organs
, vol.30
, pp. 168-177
-
-
Zhang, J.1
Gellman, B.2
Koert, A.3
Dasse, K.A.4
Gilbert, R.J.5
Griffith, B.P.6
Wu, Z.J.7
-
13
-
-
33646239626
-
Computational fluid dynamics analysis of the pediatric tiny centrifugal blood pump (TinyPump)
-
Kido K, Hoshi H, Watanabe N, et al. Computational fluid dynamics analysis of the pediatric tiny centrifugal blood pump (TinyPump). Artif Organs 2006 30 : 392 9.
-
(2006)
Artif Organs
, vol.30
, pp. 392-399
-
-
Kido, K.1
Hoshi, H.2
Watanabe, N.3
-
14
-
-
33644873240
-
Design considerations of volute geometry of a centrifugal blood pump
-
DOI 10.1111/j.1525-1594.2005.00163.x
-
Chan WK, Wong YW, Hu W. Design considerations of volute geometry of a centrifugal blood pump. Artif Organs 2005 29 : 937 48. (Pubitemid 43943029)
-
(2005)
Artificial Organs
, vol.29
, Issue.12
, pp. 937-948
-
-
Chan, W.K.1
Wong, Y.W.2
Hu, W.3
|