메뉴 건너뛰기




Volumn 25, Issue 7, 2010, Pages 1157-1161

Does ischial screw fixation improve mechanical stability in revision total hip arthroplasty?

Author keywords

Acetabulum; Revision hip arthroplasty; Screw fixation; Stability

Indexed keywords

ACETABULUM; ARTICLE; BONE SCREW; ISCHIUM; PROSTHESIS FIXATION; TOTAL HIP PROSTHESIS;

EID: 77957252418     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2009.06.025     Document Type: Article
Times cited : (23)

References (15)
  • 1
    • 2442509761 scopus 로고    scopus 로고
    • Cementless acetabular revision with the Harris-Galante porous prosthesis. Results after a minimum of ten years of follow-up
    • Hallstrom B.R., et al. Cementless acetabular revision with the Harris-Galante porous prosthesis. Results after a minimum of ten years of follow-up. J Bone Joint Surg Am 2004, 86-A:1007.
    • (2004) J Bone Joint Surg Am , pp. 1007
    • Hallstrom, B.R.1
  • 2
    • 1842528947 scopus 로고    scopus 로고
    • Cementless acetabular reconstruction in revision total hip arthroplasty
    • Della Valle C.J., et al. Cementless acetabular reconstruction in revision total hip arthroplasty. Clin Orthop 2004, 96.
    • (2004) Clin Orthop , pp. 96
    • Della Valle, C.J.1
  • 3
    • 0035181442 scopus 로고    scopus 로고
    • Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study
    • Templeton J.E., et al. Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study. J Bone Joint Surg Am 2001, 83-A:1706.
    • (2001) J Bone Joint Surg Am , pp. 1706
    • Templeton, J.E.1
  • 4
    • 0030017201 scopus 로고    scopus 로고
    • Porous-coated acetabular components with screw fixation. Five to ten-year results
    • Latimer H.A., Lachiewicz P.F. Porous-coated acetabular components with screw fixation. Five to ten-year results. J Bone Joint Surg Am 1996, 78:975.
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 975
    • Latimer, H.A.1    Lachiewicz, P.F.2
  • 5
    • 0027075129 scopus 로고
    • Acetabular micromotion as a measure of initial implant stability in primary hip arthroplasty. An in vitro comparison of different methods of initial acetabular component fixation
    • Perona P.G., et al. Acetabular micromotion as a measure of initial implant stability in primary hip arthroplasty. An in vitro comparison of different methods of initial acetabular component fixation. J Arthroplasty 1992, 7:537.
    • (1992) J Arthroplasty , vol.7 , pp. 537
    • Perona, P.G.1
  • 6
    • 0026334129 scopus 로고
    • Screw-augmented fixation of acetabular components. A mechanical model to determine optimal screw placement
    • Stranne S.K., et al. Screw-augmented fixation of acetabular components. A mechanical model to determine optimal screw placement. J Arthroplasty 1991, 6:301.
    • (1991) J Arthroplasty , vol.6 , pp. 301
    • Stranne, S.K.1
  • 7
    • 0029004699 scopus 로고
    • Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation
    • Won C.H., Hearn T.C., Tile M. Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation. J Bone Joint Surg Br 1995, 77:484.
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 484
    • Won, C.H.1    Hearn, T.C.2    Tile, M.3
  • 8
    • 0033622796 scopus 로고    scopus 로고
    • Mechanical validation of whole bone composite tibia models
    • Cristofolini L., Viceconti M. Mechanical validation of whole bone composite tibia models. J Biomech 2000, 33:279.
    • (2000) J Biomech , vol.33 , pp. 279
    • Cristofolini, L.1    Viceconti, M.2
  • 9
    • 0030131155 scopus 로고    scopus 로고
    • Mechanical validation of whole bone composite femur models
    • Cristofolini L., et al. Mechanical validation of whole bone composite femur models. J Biomech 1996, 29:525.
    • (1996) J Biomech , vol.29 , pp. 525
    • Cristofolini, L.1
  • 10
    • 0034922981 scopus 로고    scopus 로고
    • Structural properties of a new design of composite replicate femurs and tibias
    • Heiner A.D., Brown T.D. Structural properties of a new design of composite replicate femurs and tibias. J Biomech 2001, 34:773.
    • (2001) J Biomech , vol.34 , pp. 773
    • Heiner, A.D.1    Brown, T.D.2
  • 11
    • 0038351046 scopus 로고    scopus 로고
    • A biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell
    • Haft G.F., et al. A biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell. J Bone Joint Surg Am 2003, 85-A:1100.
    • (2003) J Bone Joint Surg Am , pp. 1100
    • Haft, G.F.1
  • 12
    • 0032616716 scopus 로고    scopus 로고
    • Press-fit acetabular cup fixation: principles and testing
    • Macdonald W., et al. Press-fit acetabular cup fixation: principles and testing. Proc Inst Mech Eng [H] 1999, 213:33.
    • (1999) Proc Inst Mech Eng [H] , vol.213 , pp. 33
    • Macdonald, W.1
  • 13
    • 0032905061 scopus 로고    scopus 로고
    • The Harris-Galante porous-coated acetabular component with screw fixation. An average ten-year follow-up study
    • Clohisy J.C., Harris W.H. The Harris-Galante porous-coated acetabular component with screw fixation. An average ten-year follow-up study. J Bone Joint Surg Am 1999, 81:66.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 66
    • Clohisy, J.C.1    Harris, W.H.2
  • 14
    • 0942301365 scopus 로고    scopus 로고
    • Factors influencing the longer-term survival of uncemented acetabular components used in total hip revisions
    • Jones C.P., Lachiewicz P.F. Factors influencing the longer-term survival of uncemented acetabular components used in total hip revisions. J Bone Joint Surg Am 2004, 86-A:342.
    • (2004) J Bone Joint Surg Am , pp. 342
    • Jones, C.P.1    Lachiewicz, P.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.