메뉴 건너뛰기




Volumn 10, Issue 7, 2010, Pages 6439-6462

Enzyme immobilization strategies and electropolymerization conditions to control sensitivity and selectivity parameters of a polymer-enzyme composite glucose biosensor

Author keywords

Amperometry; Ascorbic acid interference; Brain monitoring; Enzyme modified electrode; Hydrogen peroxide; Polyphenylenediamine

Indexed keywords

AMPEROMETRY; ASCORBIC ACID INTERFERENCE; BACK GROUND ELECTROLYTE; BRAIN MONITORING; CONCENTRATION DEPENDENCE; GLUCOSE OXIDASES (GOX); ORTHO-PHENYLENEDIAMINE; POLYPHENYLENEDIAMINE;

EID: 77957143584     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s100706439     Document Type: Article
Times cited : (62)

References (88)
  • 1
    • 43449137845 scopus 로고    scopus 로고
    • Bond-rupture immunosensors-A review. Biosens
    • Hirst, E.R.; Yuan, Y.J.; Xu, W.L.; Bronlund, J.E. Bond-rupture immunosensors-A review. Biosens. Bioelectron. 2008, 23, 1759-1768.
    • (2008) Bioelectron , vol.23 , pp. 1759-1768
    • Hirst, E.R.1    Yuan, Y.J.2    Xu, W.L.3    Bronlund, J.E.4
  • 2
    • 44849121927 scopus 로고    scopus 로고
    • Recent biosensing developments in environmental security
    • Wanekaya, A.K.; Chen, W.; Mulchandani, A. Recent biosensing developments in environmental security. J. Environ. Monit. 2008, 10, 703-712.
    • (2008) J. Environ. Monit , vol.10 , pp. 703-712
    • Wanekaya, A.K.1    Chen, W.2    Mulchandani, A.3
  • 3
    • 64549099815 scopus 로고    scopus 로고
    • Status of biomolecular recognition using electrochemical techniques
    • Sadik, O.A.; Aluoch, A.O.; Zhou, A.L. Status of biomolecular recognition using electrochemical techniques. Biosens. Bioelectron. 2009, 24, 2749-2765.
    • (2009) Biosens. Bioelectron , vol.24 , pp. 2749-2765
    • Sadik, O.A.1    Aluoch, A.O.2    Zhou, A.L.3
  • 4
    • 58849127006 scopus 로고    scopus 로고
    • Nanotechnology and its applications in the food sector
    • Sozer, N.; Kokini, J.L. Nanotechnology and its applications in the food sector. Trends Biotechnol. 2009, 27, 82-89.
    • (2009) Trends Biotechnol , vol.27 , pp. 82-89
    • Sozer, N.1    Kokini, J.L.2
  • 6
    • 69549114620 scopus 로고    scopus 로고
    • Electrochemical biosensors at the nanoscale
    • Wei, D.; Bailey, M.J.A.; Andrew, P.; Ryhanen, T. Electrochemical biosensors at the nanoscale. Lab Chip 2009, 9, 2123-2131.
    • (2009) Lab Chip , vol.9 , pp. 2123-2131
    • Wei, D.1    Bailey, M.J.A.2    Andrew, P.3    Ryhanen, T.4
  • 8
    • 67650716740 scopus 로고    scopus 로고
    • Wireless, remote-query, and high sensitivity escherichia coli O157:H7 biosensor based on the recognition action of Concanavalin A
    • Lu, Q.Z.; Lin, H.L.; Ge, S.T.; Luo, S.L.; Cai, Q.Y.; Grimes, C.A. Wireless, remote-query, and high sensitivity escherichia coli O157:H7 biosensor based on the recognition action of Concanavalin A. Anal. Chem. 2009, 81, 5846-5850.
    • (2009) Anal. Chem , vol.81 , pp. 5846-5850
    • Lu, Q.Z.1    Lin, H.L.2    Ge, S.T.3    Luo, S.L.4    Cai, Q.Y.5    Grimes, C.A.6
  • 9
    • 65749098398 scopus 로고    scopus 로고
    • Microelectrode biosensor for real time monitoring of L-glutamate release
    • Tian, F.M.; Gourine, A.V.; Huckstepp, R.T.R.; Dale, N. A microelectrode biosensor for real time monitoring of L-glutamate release. Anal. Chim. Acta 2009, 645, 86-91.
    • (2009) Anal. Chim. Acta , vol.645 , pp. 86-91
    • Tian, F.M.1    Gourine, A.V.2    Huckstepp, R.T.R.3    Dale, N.A.4
  • 11
    • 39149120825 scopus 로고    scopus 로고
    • Designing sensitive and selective polymer/enzyme composite biosensors for brain monitoring in vivo
    • O'Neill, R.D.; Lowry, J.P.; Rocchitta, G.; McMahon, C.P.; Serra, P.A. Designing sensitive and selective polymer/enzyme composite biosensors for brain monitoring in vivo. Trends Anal. Chem. 2008, 27, 78-88.
    • (2008) Trends Anal. Chem , vol.27 , pp. 78-88
    • O'Neill, R.D.1    Lowry, J.P.2    Rocchitta, G.3    McMahon, C.P.4    Serra, P.A.5
  • 13
    • 40449109054 scopus 로고    scopus 로고
    • Electrochemical glucose biosensors
    • Wang, J. Electrochemical glucose biosensors. Chem. Rev. 2008, 108, 814-825.
    • (2008) Chem. Rev , vol.108 , pp. 814-825
    • Wang, J.1
  • 14
    • 18044367556 scopus 로고    scopus 로고
    • Biosensors for real-time in vivo measurements
    • Wilson, G.S.; Gifford, R. Biosensors for real-time in vivo measurements. Biosens. Bioelectron. 2005, 20, 2388-2403.
    • (2005) Biosens. Bioelectron , vol.20 , pp. 2388-2403
    • Wilson, G.S.1    Gifford, R.2
  • 15
    • 0041878432 scopus 로고    scopus 로고
    • Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals
    • Burmeister, J.J.; Gerhardt, G.A. Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals. Trends Anal. Chem. 2003, 22, 498-502.
    • (2003) Trends Anal. Chem , vol.22 , pp. 498-502
    • Burmeister, J.J.1    Gerhardt, G.A.2
  • 16
    • 84988073800 scopus 로고
    • Enzyme-modified microelectrodes for in vivo neurochemical measurements
    • Pantano, P.; Kuhr, W.G. Enzyme-modified microelectrodes for in vivo neurochemical measurements. Electroanalysis 1995, 7, 405-416.
    • (1995) Electroanalysis , vol.7 , pp. 405-416
    • Pantano, P.1    Kuhr, W.G.2
  • 17
    • 0003076865 scopus 로고    scopus 로고
    • Behaviourally induced changes in extracellular levels of brain glutamate monitored at 1 s resolution with an implanted biosensor
    • Lowry, J.P.; Ryan, M.R.; O'Neill, R.D. Behaviourally induced changes in extracellular levels of brain glutamate monitored at 1 s resolution with an implanted biosensor. Anal. Commun. 1998, 35, 87-89.
    • (1998) Anal. Commun , vol.35 , pp. 87-89
    • Lowry, J.P.1    Ryan, M.R.2    O'Neill, R.D.3
  • 18
    • 33746007463 scopus 로고    scopus 로고
    • Highly selective microbiosensors for in vivo measurement of glucose, lactate and glutamate
    • Schuvailo, O.M.; Soldatkin, O.O.; Lefebvre, A.; Cespuglio, R.; Soldatkin, A.P. Highly selective microbiosensors for in vivo measurement of glucose, lactate and glutamate. Anal. Chim. Acta 2006, 573, 110-116.
    • (2006) Anal. Chim. Acta , vol.573 , pp. 110-116
    • Schuvailo, O.M.1    Soldatkin, O.O.2    Lefebvre, A.3    Cespuglio, R.4    Soldatkin, A.P.5
  • 19
    • 33748534784 scopus 로고    scopus 로고
    • Permeability and permselectivity of polyphenylenediamine films synthesized at a palladium disk electrode
    • Dai, Y.Q.; Zhou, D.M.; Shiu, K.K. Permeability and permselectivity of polyphenylenediamine films synthesized at a palladium disk electrode. Electrochim. Acta 2006, 52, 297-303.
    • (2006) Electrochim. Acta , vol.52 , pp. 297-303
    • Dai, Y.Q.1    Zhou, D.M.2    Shiu, K.K.3
  • 20
    • 0030189432 scopus 로고    scopus 로고
    • Electropolymerization of hydroxybenzene and aminobenzene isomers on platinum electrodes to assemble interference-free electrochemical biosensors
    • Carelli, I.; Chiarotto, I.; Curulli, A.; Palleschi, G. Electropolymerization of hydroxybenzene and aminobenzene isomers on platinum electrodes to assemble interference-free electrochemical biosensors. Electrochim. Acta 1996, 41, 1793-1800.
    • (1996) Electrochim. Acta , vol.41 , pp. 1793-1800
    • Carelli, I.1    Chiarotto, I.2    Curulli, A.3    Palleschi, G.4
  • 21
    • 0036708507 scopus 로고    scopus 로고
    • Novel multifunctional polymers from aromatic diamines by oxidative polymerisations
    • Li, X.G.; Huang, M.R.; Duan, W.; Yang, Y.L. Novel multifunctional polymers from aromatic diamines by oxidative polymerisations. Chem. Rev. 2002, 102, 2925-3030.
    • (2002) Chem. Rev , vol.102 , pp. 2925-3030
    • Li, X.G.1    Huang, M.R.2    Duan, W.3    Yang, Y.L.4
  • 22
    • 48049083545 scopus 로고    scopus 로고
    • Characterization of permselective coatings electrosynthesized on Pt-Ir from the three phenylenediamine isomers for biosensor applications
    • Killoran, S.J.; O'Neill, R.D. Characterization of permselective coatings electrosynthesized on Pt-Ir from the three phenylenediamine isomers for biosensor applications. Electrochim. Acta 2008, 53, 7303-7312.
    • (2008) Electrochim. Acta , vol.53 , pp. 7303-7312
    • Killoran, S.J.1    O'Neill, R.D.2
  • 23
    • 27544496216 scopus 로고    scopus 로고
    • Design variations of a polymer-enzyme composite biosensor for glucose: Enhanced analyte sensitivity without increased oxygen dependence
    • McMahon, C.P.; Killoran, S.J.; O'Neill, R.D. Design variations of a polymer-enzyme composite biosensor for glucose: Enhanced analyte sensitivity without increased oxygen dependence. J. Electroanal. Chem. 2005, 580, 193-202.
    • (2005) J. Electroanal. Chem , vol.580 , pp. 193-202
    • McMahon, C.P.1    Killoran, S.J.2    O'Neill, R.D.3
  • 24
    • 0030727757 scopus 로고    scopus 로고
    • Biosensor for neurotransmitter L-glutamic acid designed for efficient use of L-glutamate oxidase and effective rejection of interference
    • Ryan, M.R.; Lowry, J.P.; O'Neill, R.D. Biosensor for neurotransmitter L-glutamic acid designed for efficient use of L-glutamate oxidase and effective rejection of interference. Analyst 1997, 122, 1419-1424.
    • (1997) Analyst , vol.122 , pp. 1419-1424
    • Ryan, M.R.1    Lowry, J.P.2    O'Neill, R.D.3
  • 25
    • 0001597817 scopus 로고
    • Glutamate oxidase enzyme electrodes: Microsensors for neurotransmitter determination using electrochemically polymerized permselective films
    • Cooper, J.M.; Foreman, P.L.; Glidle, A.; Ling, T.W.; Pritchard, D.J. Glutamate oxidase enzyme electrodes: microsensors for neurotransmitter determination using electrochemically polymerized permselective films. J. Electroanal. Chem. 1995, 388, 143-149.
    • (1995) J. Electroanal. Chem , vol.388 , pp. 143-149
    • Cooper, J.M.1    Foreman, P.L.2    Glidle, A.3    Ling, T.W.4    Pritchard, D.J.5
  • 26
    • 0000707017 scopus 로고
    • Electropolymerized 1, 2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors
    • Sasso, S.V.; Pierce, R.J.; Walla, R.; Yacynych, A.M. Electropolymerized 1, 2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors. Anal. Chem. 1990, 62, 1111-1117.
    • (1990) Anal. Chem , vol.62 , pp. 1111-1117
    • Sasso, S.V.1    Pierce, R.J.2    Walla, R.3    Yacynych, A.M.4
  • 27
    • 33645688056 scopus 로고    scopus 로고
    • Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate
    • McMahon, C.P.; Rocchitta, G.; Serra, P.A.; Kirwan, S.M.; Lowry, J.P.; O'Neill, R.D. Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate. Anal. Chem. 2006, 78, 2352-2359.
    • (2006) Anal. Chem , vol.78 , pp. 2352-2359
    • McMahon, C.P.1    Rocchitta, G.2    Serra, P.A.3    Kirwan, S.M.4    Lowry, J.P.5    O'Neill, R.D.6
  • 28
    • 33846341424 scopus 로고    scopus 로고
    • Oxygen tolerance of an implantable polymer/enzyme composite glutamate biosensor displaying polycation-enhanced substrate sensitivity
    • McMahon, C.P.; Rocchitta, G.; Kirwan, S.M.; Killoran, S.J.; Serra, P.A.; Lowry, J.P.; O'Neill, R.D. Oxygen tolerance of an implantable polymer/enzyme composite glutamate biosensor displaying polycation-enhanced substrate sensitivity. Biosens. Bioelectron. 2007, 22, 1466-1473.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 1466-1473
    • McMahon, C.P.1    Rocchitta, G.2    Kirwan, S.M.3    Killoran, S.J.4    Serra, P.A.5    Lowry, J.P.6    O'Neill, R.D.7
  • 29
    • 34249092953 scopus 로고    scopus 로고
    • Development and characterization in vitro of a catalase-based biosensor for hydrogen peroxide monitoring
    • O'Brien, K.B.; Killoran, S.J.; O'Neill, R.D.; Lowry, J.P. Development and characterization in vitro of a catalase-based biosensor for hydrogen peroxide monitoring. Biosens. Bioelectron. 2007, 22, 2994-3000.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 2994-3000
    • O'Brien, K.B.1    Killoran, S.J.2    O'Neill, R.D.3    Lowry, J.P.4
  • 30
    • 84987467040 scopus 로고
    • Partial characterization in vitro of glucose oxidase-modified poly(phenylenediamine)-coated electrodes for neurochemical analysis in vivo
    • Lowry, J.P.; O'Neill, R.D. Partial characterization in vitro of glucose oxidase-modified poly(phenylenediamine)-coated electrodes for neurochemical analysis in vivo. Electroanalysis 1994, 6, 369-379.
    • (1994) Electroanalysis , vol.6 , pp. 369-379
    • Lowry, J.P.1    O'Neill, R.D.2
  • 31
    • 0025671780 scopus 로고
    • Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film
    • Malitesta, C.; Palmisano, F.; Torsi, L.; Zambonin, P.G. Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film. Anal. Chem. 1990, 62, 2735-2740.
    • (1990) Anal. Chem , vol.62 , pp. 2735-2740
    • Malitesta, C.1    Palmisano, F.2    Torsi, L.3    Zambonin, P.G.4
  • 32
    • 11444255974 scopus 로고    scopus 로고
    • Improved platinization conditions produce a 60-fold increase in sensitivity of amperometric biosensors using glucose oxidase immobilized in poly-o-phenylenediamine
    • Reyes De Corcuera, J.I.; Cavalieri, R.P.; Powers, J.R. Improved platinization conditions produce a 60-fold increase in sensitivity of amperometric biosensors using glucose oxidase immobilized in poly-o-phenylenediamine. J. Electroanal. Chem. 2005, 575, 229-241.
    • (2005) J. Electroanal. Chem , vol.575 , pp. 229-241
    • De Reyes, C.J.I.1    Cavalieri, R.P.2    Powers, J.R.3
  • 34
    • 33845451709 scopus 로고    scopus 로고
    • Comparison of amperometric biosensors fabricated by palladium sputtering, palladium electrodeposition and Nafion/carbon nanotube casting on screen-printed carbon electrodes
    • Lee, C.H.; Wang, S.C.; Yuan, C.J.; Wen, M.F.; Chang, K.S. Comparison of amperometric biosensors fabricated by palladium sputtering, palladium electrodeposition and Nafion/carbon nanotube casting on screen-printed carbon electrodes. Biosens. Bioelectron. 2007, 22, 877-884.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 877-884
    • Lee, C.H.1    Wang, S.C.2    Yuan, C.J.3    Wen, M.F.4    Chang, K.S.5
  • 35
    • 84987472007 scopus 로고
    • Electrocatalytic oxidation of ascorbic acid at chemically modified electrodes
    • Kulys, J.; Drungiliene, A. Electrocatalytic oxidation of ascorbic acid at chemically modified electrodes. Electroanalysis 1991, 3, 209-214.
    • (1991) Electroanalysis , vol.3 , pp. 209-214
    • Kulys, J.1    Drungiliene, A.2
  • 36
    • 0004781998 scopus 로고
    • Characterisation in vitro of a naphthoquinone-mediated glucose oxidase-modified carbon paste electrode designed for neurochemical analysis in vivo
    • El Atrash, S.S.; O'Neill, R.D. Characterisation in vitro of a naphthoquinone-mediated glucose oxidase-modified carbon paste electrode designed for neurochemical analysis in vivo. Electrochim. Acta 1995, 40, 2791-2797.
    • (1995) Electrochim. Acta , vol.40 , pp. 2791-2797
    • El Atrash, S.S.1    O'Neill, R.D.2
  • 37
    • 37249087136 scopus 로고    scopus 로고
    • Facille electrochemical method for simultaneous and on-line measurements of glucose and lactate in brain microdialysate with prussian blue as the electrocatalyst for reduction of hydrogen peroxide
    • Lin, Y.Q.; Liu, K.; Yu, P.; Xiang, L.; Li, X.C.; Mao, L.Q. A facille electrochemical method for simultaneous and on-line measurements of glucose and lactate in brain microdialysate with prussian blue as the electrocatalyst for reduction of hydrogen peroxide. Anal. Chem. 2007, 79, 9577-9583.
    • (2007) Anal. Chem , vol.79 , pp. 9577-9583
    • Lin, Y.Q.1    Liu, K.2    Yu, P.3    Xiang, L.4    Li, X.C.5    Mao, L.Q.A.6
  • 38
    • 49449093805 scopus 로고    scopus 로고
    • Immobilization of enzymes through one-pot chemical preoxidation and electropolymerization of dithiols in enzyme-containing aqueous suspensions to develop biosensors with improved performance
    • Fu, Y.C.; Chen, C.; Xie, Q.J.; Xu, X.H.; Zou, C.; Zhou, Q.M.; Tan, L.; Tang, H.; Zhang, Y.Y.; Yao, S.Z. Immobilization of enzymes through one-pot chemical preoxidation and electropolymerization of dithiols in enzyme-containing aqueous suspensions to develop biosensors with improved performance. Anal. Chem. 2008, 80, 5829-5838.
    • (2008) Anal. Chem , vol.80 , pp. 5829-5838
    • Fu, Y.C.1    Chen, C.2    Xie, Q.J.3    Xu, X.H.4    Zou, C.5    Zhou, Q.M.6    Tan, L.7    Tang, H.8    Zhang, Y.Y.9    Yao, S.Z.10
  • 39
    • 0000953523 scopus 로고
    • Characterization of glucose oxidase-modified poly(phenylenediamine)-coated electrodes in vitro and in vivo: Homogeneous interference by ascorbic acid in hydrogen peroxide detection
    • Lowry, J.P.; McAteer, K.; El Atrash, S.S.; Duff, A.; O'Neill, R.D. Characterization of glucose oxidase-modified poly(phenylenediamine)-coated electrodes in vitro and in vivo: Homogeneous interference by ascorbic acid in hydrogen peroxide detection. Anal. Chem. 1994, 66, 1754-1761.
    • (1994) Anal. Chem , vol.66 , pp. 1754-1761
    • Lowry, J.P.1    McAteer, K.2    El Atrash, S.S.3    Duff, A.4    O'Neill, R.D.5
  • 40
    • 0001250737 scopus 로고    scopus 로고
    • Enhanced selectivity and sensitivity of first-generation enzyme electrodes based on the coupling of rhodinized carbon paste transducers and permselective poly(ophenylenediamine) coatings
    • Wang, J.; Chen, L.; Liu, J.; Lu, F. Enhanced selectivity and sensitivity of first-generation enzyme electrodes based on the coupling of rhodinized carbon paste transducers and permselective poly(ophenylenediamine) coatings. Electroanalysis 1996, 8, 1127-1130.
    • (1996) Electroanalysis , vol.8 , pp. 1127-1130
    • Wang, J.1    Chen, L.2    Liu, J.3    Lu, F.4
  • 41
    • 66149114037 scopus 로고    scopus 로고
    • Contributions by a novel edge effect to the permselectivity of an electrosynthesized polymer for microbiosensor applications
    • Rothwell, S.A.; Kinsella, M.E.; Zain, Z.M.; Serra, P.A.; Rocchitta, G.; Lowry, J.P.; O'Neill, R.D. Contributions by a novel edge effect to the permselectivity of an electrosynthesized polymer for microbiosensor applications. Anal. Chem. 2009, 81, 3911-3918.
    • (2009) Anal. Chem , vol.81 , pp. 3911-3918
    • Rothwell, S.A.1    Kinsella, M.E.2    Zain, Z.M.3    Serra, P.A.4    Rocchitta, G.5    Lowry, J.P.6    O'Neill, R.D.7
  • 42
    • 45649083622 scopus 로고    scopus 로고
    • Poly(o-phenylenediamine) electrosynthesized in the absence of added background electrolyte provides a new permselectivity benchmark for biosensor applications
    • Rothwell, S.A.; Killoran, S.J.; Neville, E.M.; Crotty, A.M.; O'Neill, R.D. Poly(o-phenylenediamine) electrosynthesized in the absence of added background electrolyte provides a new permselectivity benchmark for biosensor applications. Electrochem. Commun. 2008, 10, 1078-1081.
    • (2008) Electrochem. Commun , vol.10 , pp. 1078-1081
    • Rothwell, S.A.1    Killoran, S.J.2    Neville, E.M.3    Crotty, A.M.4    O'Neill, R.D.5
  • 43
    • 32844464818 scopus 로고    scopus 로고
    • Electrosynthesized poly(pyrrole)/poly(2-naphthol) bilayer membrane as an effective anti-interference layer for simultaneous determination of acethylcholine and choline by a dual electrode amperometric biosensor
    • Guerrieri, A.; Lattanzio, V.; Palmisano, F.; Zambonin, P.G. Electrosynthesized poly(pyrrole)/poly(2-naphthol) bilayer membrane as an effective anti-interference layer for simultaneous determination of acethylcholine and choline by a dual electrode amperometric biosensor. Biosens. Bioelectron. 2006, 21, 1710-1718.
    • (2006) Biosens. Bioelectron , vol.21 , pp. 1710-1718
    • Guerrieri, A.1    Lattanzio, V.2    Palmisano, F.3    Zambonin, P.G.4
  • 45
    • 0041344450 scopus 로고    scopus 로고
    • Comparison of simple aromatic amines for electrosynthesis of permselective polymers in biosensor fabrication
    • Craig, J.D.; O'Neill, R.D. Comparison of simple aromatic amines for electrosynthesis of permselective polymers in biosensor fabrication. Analyst 2003, 128, 905-911.
    • (2003) Analyst , vol.128 , pp. 905-911
    • Craig, J.D.1    O'Neill, R.D.2
  • 46
    • 0031592350 scopus 로고    scopus 로고
    • Poly(o-phenylenediamine) ultra-thin polymer-film composite membranes for enzyme electrodes
    • Myler, S.; Eaton, S.; Higson, S.P.J. Poly(o-phenylenediamine) ultra-thin polymer-film composite membranes for enzyme electrodes. Anal. Chim. Acta 1997, 357, 55-61.
    • (1997) Anal. Chim. Acta , vol.357 , pp. 55-61
    • Myler, S.1    Eaton, S.2    Higson, S.P.J.3
  • 47
    • 0001358471 scopus 로고    scopus 로고
    • Parameters in the design of oxygen detecting oxidase enzyme electrodes
    • Gooding, J.J.; Hall, E.A.H. Parameters in the design of oxygen detecting oxidase enzyme electrodes. Electroanalysis 1996, 8, 407-413.
    • (1996) Electroanalysis , vol.8 , pp. 407-413
    • Gooding, J.J.1    Hall, E.A.H.2
  • 48
    • 0037201686 scopus 로고    scopus 로고
    • Characterization in vitro and in vivo of the oxygen dependence of an enzyme/polymer biosensor for monitoring brain glucose
    • Dixon, B.M.; Lowry, J.P.; O'Neill, R.D. Characterization in vitro and in vivo of the oxygen dependence of an enzyme/polymer biosensor for monitoring brain glucose. J. Neurosci. Meth. 2002, 119, 135-142.
    • (2002) J. Neurosci. Meth , vol.119 , pp. 135-142
    • Dixon, B.M.1    Lowry, J.P.2    O'Neill, R.D.3
  • 49
    • 84987486579 scopus 로고    scopus 로고
    • A new conducting polymer glucose sensor based on polythianaphthene
    • Compagnone, D.; Federici, G.; Bannister, J.V. A new conducting polymer glucose sensor based on polythianaphthene. Electroanalysis 1996, 7, 1151-1155.
    • (1996) Electroanalysis , vol.7 , pp. 1151-1155
    • Compagnone, D.1    Federici, G.2    Bannister, J.V.3
  • 50
    • 0000299327 scopus 로고
    • An in-situ electrosynthesized poly-ortho-phenylenediamine/glucose oxidase amperometric biosensor for flow-injection determination of glucose in serum
    • Centonze, D.; Guerrieri, A.; Malitesta, C.; Palmisano, F.; Zambonin, P.G. An in-situ electrosynthesized poly-ortho-phenylenediamine/glucose oxidase amperometric biosensor for flow-injection determination of glucose in serum. Ann. Chim. (Rome) 1992, 82, 219-234.
    • (1992) Ann. Chim. (Rome) , vol.82 , pp. 219-234
    • Centonze, D.1    Guerrieri, A.2    Malitesta, C.3    Palmisano, F.4    Zambonin, P.G.5
  • 51
    • 0030560652 scopus 로고    scopus 로고
    • In vivo determination of extracellular brain ascorbate
    • Miele, M.; Fillenz, M. In vivo determination of extracellular brain ascorbate. J. Neurosci. Meth. 1996, 70, 15-19.
    • (1996) J. Neurosci. Meth , vol.70 , pp. 15-19
    • Miele, M.1    Fillenz, M.2
  • 52
    • 0024348695 scopus 로고
    • Rapid changes in striatal ascorbate in response to tail-pinch monitored by constant potential voltammetry
    • Boutelle, M.G.; Svensson, L.; Fillenz, M. Rapid changes in striatal ascorbate in response to tail-pinch monitored by constant potential voltammetry. Neuroscience 1989, 30, 11-17.
    • (1989) Neuroscience , vol.30 , pp. 11-17
    • Boutelle, M.G.1    Svensson, L.2    Fillenz, M.3
  • 53
    • 0020573098 scopus 로고
    • The development of linear sweep voltammetry with carbon paste electrodes in vivo
    • O'Neill, R.D.; Fillenz, M.; Albery, W.J. The development of linear sweep voltammetry with carbon paste electrodes in vivo. J. Neurosci. Meth. 1983, 8, 263-273.
    • (1983) J. Neurosci. Meth , vol.8 , pp. 263-273
    • O'Neill, R.D.1    Fillenz, M.2    Albery, W.J.3
  • 54
    • 0022557309 scopus 로고
    • Effects of light reversal on the circadian pattern of motor activity and voltammetric signals recorded in rat forebrain
    • London
    • Fillenz, M.; O'Neill, R.D. Effects of light reversal on the circadian pattern of motor activity and voltammetric signals recorded in rat forebrain. J. Physiol. (London) 1986, 374, 91-101.
    • (1986) J. Physiol , vol.374 , pp. 91-101
    • Fillenz, M.1    O'Neill, R.D.2
  • 55
    • 0023574828 scopus 로고
    • Effects of an anxiogenic benzodiazepine receptor ligand on rat motor activity and dopamine release in nucleus accumbens and striatum
    • Brose, N.; O'Neill, R.D.; Boutelle, M.G.; Anderson, S.M.P.; Fillenz, M. Effects of an anxiogenic benzodiazepine receptor ligand on rat motor activity and dopamine release in nucleus accumbens and striatum. J. Neurosci. 1987, 7, 2917-2926.
    • (1987) J. Neurosci , vol.7 , pp. 2917-2926
    • Brose, N.1    O'Neill, R.D.2    Boutelle, M.G.3    Anderson, S.M.P.4    Fillenz, M.5
  • 56
    • 61649092530 scopus 로고    scopus 로고
    • Microbiosensor based on glucose oxidase and hexokinase co-immobilised on platinum microelectrode for selective ATP detection
    • Soldatkin, O.O.; Schuvailo, O.M.; Marinesco, S.; Cespuglio, R.; Soldatkin, A.R. Microbiosensor based on glucose oxidase and hexokinase co-immobilised on platinum microelectrode for selective ATP detection. Talanta 2009, 78, 1023-1028.
    • (2009) Talanta , vol.78 , pp. 1023-1028
    • Soldatkin, O.O.1    Schuvailo, O.M.2    Marinesco, S.3    Cespuglio, R.4    Soldatkin, A.R.5
  • 59
    • 0029972048 scopus 로고    scopus 로고
    • Strategies for decreasing ascorbate interference at glucose oxidase-modified poly(o-phenylenediamine)-coated electrodes
    • McAteer, K.; O'Neill, R.D. Strategies for decreasing ascorbate interference at glucose oxidase-modified poly(o-phenylenediamine)-coated electrodes. Analyst 1996, 121, 773-777.
    • (1996) Analyst , vol.121 , pp. 773-777
    • McAteer, K.1    O'Neill, R.D.2
  • 60
    • 0031973311 scopus 로고    scopus 로고
    • Continuous monitoring of extracellular glucose concentrations in the striatum of freely moving rats with an implanted glucose biosensor
    • Lowry, J.P.; O'Neill, R.D.; Boutelle, M.G.; Fillenz, M. Continuous monitoring of extracellular glucose concentrations in the striatum of freely moving rats with an implanted glucose biosensor. J. Neurochem. 1998, 70, 391-396.
    • (1998) J. Neurochem , vol.70 , pp. 391-396
    • Lowry, J.P.1    O'Neill, R.D.2    Boutelle, M.G.3    Fillenz, M.4
  • 61
    • 8744232097 scopus 로고    scopus 로고
    • Highly sensitive amperometric glucose biosensor based on glassy carbon electrode with copper/palladium coating
    • Dai, Y.Q.; Shiu, K.K. Highly sensitive amperometric glucose biosensor based on glassy carbon electrode with copper/palladium coating. Electroanalysis 2004, 16, 1806-1813.
    • (2004) Electroanalysis , vol.16 , pp. 1806-1813
    • Dai, Y.Q.1    Shiu, K.K.2
  • 62
    • 0031944873 scopus 로고    scopus 로고
    • Measurement of low glucose concentrations using a microelectrochemical enzyme transistor
    • Bartlett, P.N.; Wang, J.H.; James, W. Measurement of low glucose concentrations using a microelectrochemical enzyme transistor. Analyst 1998, 123, 387-392.
    • (1998) Analyst , vol.123 , pp. 387-392
    • Bartlett, P.N.1    Wang, J.H.2    James, W.3
  • 63
    • 17344368264 scopus 로고    scopus 로고
    • Oxygen-rich oxidase enzyme electrodes for operation in oxygen-free solutions
    • Wang, J.; Lu, F. Oxygen-rich oxidase enzyme electrodes for operation in oxygen-free solutions. J. Am. Chem. Soc. 1998, 120, 1048-1050.
    • (1998) J. Am. Chem. Soc , vol.120 , pp. 1048-1050
    • Wang, J.1    Lu, F.2
  • 64
    • 0001578691 scopus 로고
    • Selectivity coefficients for amperometric sensors
    • Wang, J. Selectivity coefficients for amperometric sensors. Talanta 1994, 41, 857-863.
    • (1994) Talanta , vol.41 , pp. 857-863
    • Wang, J.1
  • 65
    • 0034325046 scopus 로고    scopus 로고
    • Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films
    • Palmisano, F.; Rizzi, R.; Centonze, D.; Zambonin, P.G. Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films. Biosens. Bioelectron. 2000, 15, 531-539.
    • (2000) Biosens. Bioelectron , vol.15 , pp. 531-539
    • Palmisano, F.1    Rizzi, R.2    Centonze, D.3    Zambonin, P.G.4
  • 66
    • 33846807467 scopus 로고    scopus 로고
    • Minimizing tissuematerial interaction in microsensor for subcutaneous glucose monitoring
    • Ahmad, F.; Christenson, A.; Bainbridge, M.; Yusof, A.P.M.; Ab Ghani, S. Minimizing tissuematerial interaction in microsensor for subcutaneous glucose monitoring. Biosens. Bioelectron. 2007, 22, 1625-1632.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 1625-1632
    • Ahmad, F.1    Christenson, A.2    Bainbridge, M.3    Yusof, A.P.M.4    Ab Ghani, S.5
  • 68
    • 0028413150 scopus 로고
    • Biomolecular sensors for neurotransmitter determination electrochemical immobilization of glutamate oxidase at microelectrodes in a poly (o-phenylenediamine) film
    • Cooper, J.M.; Pritchard, D.J. Biomolecular sensors for neurotransmitter determination electrochemical immobilization of glutamate oxidase at microelectrodes in a poly (o-phenylenediamine) film. J. Mater. Sci.: Mater. Electronl. 1994, 5, 111-116.
    • (1994) J. Mater. Sci.: Mater. Electronl , vol.5 , pp. 111-116
    • Cooper, J.M.1    Pritchard, D.J.2
  • 70
    • 30844474185 scopus 로고    scopus 로고
    • The efficiency of immobilised glutamate oxidase decreases with surface enzyme loading: An electrostatic effect, and reversal by a polycation significantly enhances biosensor sensitivity
    • McMahon, C.P.; Rocchitta, G.; Serra, P.A.; Kirwan, S.M.; Lowry, J.P.; O'Neill, R.D. The efficiency of immobilised glutamate oxidase decreases with surface enzyme loading: an electrostatic effect, and reversal by a polycation significantly enhances biosensor sensitivity. Analyst 2006, 131, 68-72.
    • (2006) Analyst , vol.131 , pp. 68-72
    • McMahon, C.P.1    Rocchitta, G.2    Serra, P.A.3    Kirwan, S.M.4    Lowry, J.P.5    O'Neill, R.D.6
  • 71
    • 0242586073 scopus 로고    scopus 로고
    • Ceramic-based multisite microelectrode array for rapid choline measures in brain tissue
    • Burmeister, J.J.; Palmer, M.; Gerhardt, G.A. Ceramic-based multisite microelectrode array for rapid choline measures in brain tissue. Anal. Chim. Acta 2003, 481, 65-74.
    • (2003) Anal. Chim. Acta , vol.481 , pp. 65-74
    • Burmeister, J.J.1    Palmer, M.2    Gerhardt, G.A.3
  • 72
    • 0028472185 scopus 로고
    • On-line measurement of brain glutamate with an enzyme/polymer-coated tubular electrode
    • Berners, M.O.M.; Boutelle, M.G.; Fillenz, M. On-line measurement of brain glutamate with an enzyme/polymer-coated tubular electrode. Anal. Chem. 1994, 66, 2017-2021.
    • (1994) Anal. Chem , vol.66 , pp. 2017-2021
    • Berners, M.O.M.1    Boutelle, M.G.2    Fillenz, M.3
  • 73
    • 0032713074 scopus 로고    scopus 로고
    • Monitoring glutamate and ascorbate in the extracellular space of brain tissue with electrochemical microsensors
    • Kulagina, N.V.; Shankar, L.; Michael, A.C. Monitoring glutamate and ascorbate in the extracellular space of brain tissue with electrochemical microsensors. Anal. Chem. 1999, 71, 5093-5100.
    • (1999) Anal. Chem , vol.71 , pp. 5093-5100
    • Kulagina, N.V.1    Shankar, L.2    Michael, A.C.3
  • 74
    • 24544475927 scopus 로고
    • Controlled-potential coulometric determination of hydrogen peroxide
    • Harrar, J.E. Controlled-potential coulometric determination of hydrogen peroxide. Anal. Chem. 1963, 35, 893-896.
    • (1963) Anal. Chem , vol.35 , pp. 893-896
    • Harrar, J.E.1
  • 75
    • 70549086062 scopus 로고    scopus 로고
    • Effects of polymerization potential on the permselectivity of poly(o-phenylenediamine) coatings deposited on Pt-Ir electrodes for biosensor applications
    • Rothwell, S.A.; McMahon, C.P.; O'Neill, R.D. Effects of polymerization potential on the permselectivity of poly(o-phenylenediamine) coatings deposited on Pt-Ir electrodes for biosensor applications. Electrochim. Acta 2010, 55, 1051-1060.
    • (2010) Electrochim. Acta , vol.55 , pp. 1051-1060
    • Rothwell, S.A.1    McMahon, C.P.2    O'Neill, R.D.3
  • 76
    • 38749117858 scopus 로고    scopus 로고
    • Second-by-second measures of L-glutamate in the prefrontal cortex and striatum of freely moving mice
    • Hascup, K.N.; Hascup, E.R.; Pomerleau, F.; Huettl, P.; Gerhardt, G.A. Second-by-second measures of L-glutamate in the prefrontal cortex and striatum of freely moving mice. J. Pharmacol. Exp. Ther. 2008, 324, 725-731.
    • (2008) J. Pharmacol. Exp. Ther , vol.324 , pp. 725-731
    • Hascup, K.N.1    Hascup, E.R.2    Pomerleau, F.3    Huettl, P.4    Gerhardt, G.A.5
  • 77
    • 38049069282 scopus 로고    scopus 로고
    • Simultaneous glutamate and EEG activity measurements during seizures in rat hippocampal region with the use of an electrochemical biosensor
    • Morales-Villagran, A.; Medina-Ceja, L.; Lopez-Perez, S.J. Simultaneous glutamate and EEG activity measurements during seizures in rat hippocampal region with the use of an electrochemical biosensor. J. Neurosci. Meth. 2008, 168, 48-53.
    • (2008) J. Neurosci. Meth , vol.168 , pp. 48-53
    • Morales-Villagran, A.1    Medina-Ceja, L.2    Lopez-Perez, S.J.3
  • 78
    • 34249311592 scopus 로고    scopus 로고
    • One-step electrochemically deposited interface of chitosan-gold nanoparticles for acetylcholinesterase biosensor design
    • Du, D.; Ding, J.W.; Cai, J.; Zhang, A.D. One-step electrochemically deposited interface of chitosan-gold nanoparticles for acetylcholinesterase biosensor design. J. Electroanal. Chem. 2007, 605, 53-60.
    • (2007) J. Electroanal. Chem , vol.605 , pp. 53-60
    • Du, D.1    Ding, J.W.2    Cai, J.3    Zhang, A.D.4
  • 79
    • 22744447349 scopus 로고    scopus 로고
    • Listening to the brain: Microelectrode biosensors for neurochemicals
    • Dale, N.; Hatz, S.; Tian, F.M.; Llaudet, E. Listening to the brain: microelectrode biosensors for neurochemicals. Trends Biotechnol. 2005, 23, 420-428.
    • (2005) Trends Biotechnol , vol.23 , pp. 420-428
    • Dale, N.1    Hatz, S.2    Tian, F.M.3    Llaudet, E.4
  • 80
    • 33751236818 scopus 로고    scopus 로고
    • Detection of nitric oxide release from single neurons in the pond snail, Lymnaea stagnalis
    • Patel, B.A.; Arundell, M.; Parker, K.H.; Yeoman, M.S.; O'Hare, D. Detection of nitric oxide release from single neurons in the pond snail, Lymnaea stagnalis. Anal. Chem. 2006, 78, 7643-7648.
    • (2006) Anal. Chem , vol.78 , pp. 7643-7648
    • Patel, B.A.1    Arundell, M.2    Parker, K.H.3    Yeoman, M.S.4    O'Hare, D.5
  • 81
    • 0141924474 scopus 로고    scopus 로고
    • O-Phenylenediamine electropolymerization by cyclic voltammetry combined with electrospray ionization-ion trap mass spectrometry
    • Losito, I.; Palmisano, F.; Zambonin, P.G. o-Phenylenediamine electropolymerization by cyclic voltammetry combined with electrospray ionization-ion trap mass spectrometry. Anal. Chem. 2003, 75, 4988-4995.
    • (2003) Anal. Chem , vol.75 , pp. 4988-4995
    • Losito, I.1    Palmisano, F.2    Zambonin, P.G.3
  • 82
    • 0034157849 scopus 로고    scopus 로고
    • Amperometric biosensors based on electrosynthesised polymeric films. Fresenius
    • Palmisano, F.; Zambonin, P.G.; Centonze, D. Amperometric biosensors based on electrosynthesised polymeric films. Fresenius J. Anal. Chem. 2000, 366, 586-601.
    • (2000) J. Anal. Chem , vol.366 , pp. 586-601
    • Palmisano, F.1    Zambonin, P.G.2    Centonze, D.3
  • 83
    • 0031219872 scopus 로고    scopus 로고
    • Electrochemical immobilisation of enzymes on conducting organic salt electrodes: Characterisation of an oxygen independent and interference-free glucose biosensor
    • Centonze, D.; Losito, I.; Malitesta, C.; Palmisano, F.; Zambonin, P.G. Electrochemical immobilisation of enzymes on conducting organic salt electrodes: characterisation of an oxygen independent and interference-free glucose biosensor. J. Electroanal. Chem. 1997, 435, 103-111.
    • (1997) J. Electroanal. Chem , vol.435 , pp. 103-111
    • Centonze, D.1    Losito, I.2    Malitesta, C.3    Palmisano, F.4    Zambonin, P.G.5
  • 84
    • 42049101821 scopus 로고    scopus 로고
    • The preparation and characterization of poly(o-phenylenediamine)/gold nanoparticles interface for immunoassay by surface plasmon resonance and electrochemistry
    • Wang, Q.; Tang, H.; Xie, Q.J.; Jia, X.E.; Zhang, Y.Y.; Tan, L.; Yao, S.Z. The preparation and characterization of poly(o-phenylenediamine)/gold nanoparticles interface for immunoassay by surface plasmon resonance and electrochemistry. Colloid. Surface. B 2008, 63, 254-261.
    • (2008) Colloid. Surface. B , vol.63 , pp. 254-261
    • Wang, Q.1    Tang, H.2    Xie, Q.J.3    Jia, X.E.4    Zhang, Y.Y.5    Tan, L.6    Yao, S.Z.7
  • 85
    • 27744456735 scopus 로고    scopus 로고
    • Modelling of the initial stages of the electropolymerization mechanism of o-phenylenediamine
    • Camurri, G.; Ferrarini, P.; Giovanardi, R.; Benassi, R.; Fontanesi, C. Modelling of the initial stages of the electropolymerization mechanism of o-phenylenediamine. J. Electroanal. Chem. 2005, 585, 181-190.
    • (2005) J. Electroanal. Chem , vol.585 , pp. 181-190
    • Camurri, G.1    Ferrarini, P.2    Giovanardi, R.3    Benassi, R.4    Fontanesi, C.5
  • 86
    • 0034940546 scopus 로고    scopus 로고
    • Spectroscopic investigation on polymer films obtained by oxidation of o-phenylenediamine on platinum electrodes at different pHs
    • Losito, I.; De Giglio, E.; Cioffi, N.; Malitesta, C. Spectroscopic investigation on polymer films obtained by oxidation of o-phenylenediamine on platinum electrodes at different pHs. J. Mater. Chem. 2001, 11, 1812-1817.
    • (2001) J. Mater. Chem , vol.11 , pp. 1812-1817
    • Losito, I.1    de Giglio, E.2    Cioffi, N.3    Malitesta, C.4
  • 87
    • 0035151705 scopus 로고    scopus 로고
    • Preparation, optimization, and voltammetric characteristics of poly(o-phenylenediamine) film as a dopamine-selective polymeric membrane
    • Ekinci, E.; Erdogdu, G.; Karagozler, A.E. Preparation, optimization, and voltammetric characteristics of poly(o-phenylenediamine) film as a dopamine-selective polymeric membrane. J. Appl. Polym. Sci. 2001, 79, 327-332.
    • (2001) J. Appl. Polym. Sci , vol.79 , pp. 327-332
    • Ekinci, E.1    Erdogdu, G.2    Karagozler, A.E.3
  • 88
    • 84987564714 scopus 로고
    • Permeation of solutes through an electropolymerized ultrathin poly-o-phenylenediamine film used as an enzyme-entrapping membrane
    • Centonze, D.; Malitesta, C.; Palmisano, F.; Zambonin, P.G. Permeation of solutes through an electropolymerized ultrathin poly-o-phenylenediamine film used as an enzyme-entrapping membrane. Electroanalysis 1994, 6, 423-429.
    • (1994) Electroanalysis , vol.6 , pp. 423-429
    • Centonze, D.1    Malitesta, C.2    Palmisano, F.3    Zambonin, P.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.