메뉴 건너뛰기




Volumn 26, Issue 3, 2010, Pages 379-382

Comparison of hemodynamic changes and ease of endotracheal intubation through I-gel vs. ILMA

Author keywords

Endotracheal intubation; Haemodynamics; I gel; Intubating laryngeal mask airway

Indexed keywords

ADULT; ANESTHETIC EQUIPMENT; ARTERIAL OXYGEN SATURATION; ARTICLE; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; END TIDAL CARBON DIOXIDE TENSION; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; FEMALE; HEMODYNAMIC MONITORING; HUMAN; INSTRUMENT VALIDATION; INTERMETHOD COMPARISON; LARYNGEAL MASK; MALE; MEAN ARTERIAL PRESSURE; PATIENT SAFETY; POSTOPERATIVE COMPLICATION; PULSE RATE; RESPIRATORY TRACT INJURY; SORE THROAT;

EID: 77957095671     PISSN: 09709185     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (16)
  • 1
    • 41349109832 scopus 로고    scopus 로고
    • A new single use supraglottic airway with a noninflatable cuff and an esophageal vent: An observational study of the i-gel
    • Richez B, Saltel L, Banchereau F, Torrielli, Cros AM: A new single use supraglottic airway with a noninflatable cuff and an esophageal vent: An observational study of the i-gel: Anesth Analg 2008; 106(4): 1137-1139.
    • (2008) Anesth Analg , vol.106 , Issue.4 , pp. 1137-1139
    • Richez, B.1    Saltel, L.2    Banchereau, F.3    Torrielli, C.A.M.4
  • 2
    • 40949105091 scopus 로고    scopus 로고
    • Effect of chest compressions on the time taken to insert airway devices in a manikin
    • Gatward JJ, Thomas MJC, Nolan JP, Cook TM: Effect of chest compressions on the time taken to insert airway devices in a manikin: Br J Anaesth 2008; 100(3): 351-356
    • (2008) Br J Anaesth , vol.100 , Issue.3 , pp. 351-356
    • Gatward, J.J.1    Thomas, M.J.C.2    Nolan, J.P.3    Cook, T.M.4
  • 3
    • 33847369136 scopus 로고    scopus 로고
    • The i-gel supraglottic airway: A potential role for resuscitation?
    • Gabbott DA, Beringer R: The i-gel supraglottic airway: A potential role for resuscitation?: Resuscitation 2007; 73(1): 161-162.
    • (2007) Resuscitation , vol.73 , Issue.1 , pp. 161-162
    • Gabbott, D.A.1    Beringer, R.2
  • 4
    • 34250020474 scopus 로고    scopus 로고
    • The i-gel supraglottic airway and resuscitation - some initial thoughts
    • Soar J: The i-gel supraglottic airway and resuscitation - some initial thoughts: Resuscitation 2007; 74(1): 197.
    • (2007) Resuscitation , vol.74 , Issue.1 , pp. 197
    • Soar, J.1
  • 5
    • 42449161500 scopus 로고    scopus 로고
    • Fiberoptic intubation through an I-Gel supraglottic airway in two patients with predicted difficult airway and intellectual disability
    • Michalek P, Hodgkinson P, and Donaldson W. Fiberoptic intubation through an I-Gel supraglottic airway in two patients with predicted difficult airway and intellectual disability. Anesth Analg 2008; 106: 1501-1504
    • (2008) Anesth Analg , vol.106 , pp. 1501-1504
    • Michalek, P.1    Hodgkinson, P.2    Donaldson, W.3
  • 6
    • 0033017079 scopus 로고    scopus 로고
    • The intubating laryngeal mask airway with and without fiberoptic guidance
    • Joo HS, Rose DK. The intubating laryngeal mask airway with and without fiberoptic guidance. Anesth Analg 1999; 88: 662-666.
    • (1999) Anesth Analg , vol.88 , pp. 662-666
    • Joo, H.S.1    Rose, D.K.2
  • 7
    • 0036799359 scopus 로고    scopus 로고
    • Intubating laryngeal mask airway
    • Caponas G. Intubating laryngeal mask airway. Anaesth Intensive care 2002; 30: 551-569.
    • (2002) Anaesth Intensive Care , vol.30 , pp. 551-569
    • Caponas, G.1
  • 8
    • 0036791669 scopus 로고    scopus 로고
    • Difficulty in use and device failure with the intubating laryngeal mask airway
    • Caponas G, Popat M. Difficulty in use and device failure with the intubating laryngeal mask airway. Eur J Anaesthesiol 2002; 19: 764-766
    • (2002) Eur J Anaesthesiol , vol.19 , pp. 764-766
    • Caponas, G.1    Popat, M.2
  • 9
    • 0032929862 scopus 로고    scopus 로고
    • An unexpected complication of the intubating laryngeal mask
    • Branthwaite MA. An unexpected complication of the intubating laryngeal mask. Anaesthesia 1999; 54: 166-171
    • (1999) Anaesthesia , vol.54 , pp. 166-171
    • Branthwaite, M.A.1
  • 10
    • 51349098907 scopus 로고    scopus 로고
    • Evaluation of the i-gel airway in 300 patients
    • Bamgbade OA, Macnab WR, Khalaf WM: Evaluation of the i-gel airway in 300 patients. Eur J Anaesthesiol. 2008; 25(10): 865-866.
    • (2008) Eur J Anaesthesiol , vol.25 , Issue.10 , pp. 865-866
    • Bamgbade, O.A.1    Macnab, W.R.2    Khalaf, W.M.3
  • 11
    • 33947654834 scopus 로고    scopus 로고
    • Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices
    • Jackson KM, Cook TM. Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia 2007; 62: 388-393.
    • (2007) Anaesthesia , vol.62 , pp. 388-393
    • Jackson, K.M.1    Cook, T.M.2
  • 12
    • 72049087705 scopus 로고    scopus 로고
    • A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: A Manikin Study
    • Michalek P, Donaldson W, Graham C, Hinds J. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: A manikin study. Resuscitation 81; 1:74-77
    • Resuscitation , vol.81 , Issue.1 , pp. 74-77
    • Michalek, P.1    Donaldson, W.2    Graham, C.3    Hinds, J.4
  • 13
    • 34547887992 scopus 로고    scopus 로고
    • Intubating laryngeal mask airway for difficult out of hospital airway management: A prospective evaluation
    • Timmermann A, Russo SG, Rosenblatt WH et al. Intubating laryngeal mask airway for difficult out of hospital airway management: a prospective evaluation. Br J Anaesth 2007; 99(2) 286-291.
    • (2007) Br J Anaesth , vol.99 , Issue.2 , pp. 286-291
    • Timmermann, A.1    Russo, S.G.2    Rosenblatt, W.H.3
  • 14
    • 0031723361 scopus 로고    scopus 로고
    • The intubating Laryngeal mask: Results of multicentric trial with experience
    • Baskett PJ, Parr MJ, Nolan JP. The intubating Laryngeal mask: results of multicentric trial with experience. Anaesthesia 1998; 53: 1174-1179.
    • (1998) Anaesthesia , vol.53 , pp. 1174-1179
    • Baskett, P.J.1    Parr, M.J.2    Nolan, J.P.3
  • 15
    • 51349155510 scopus 로고    scopus 로고
    • Evaluation of size 4 I-gel airway in one hundred non-paralyzed patients
    • Gatward J J, Cook T M, Seller C et al. Evaluation of size 4 I-gel airway in one hundred non-paralyzed patients. Anaesthesia; 63; 10: 1124-1130.
    • Anaesthesia , vol.63 , Issue.10 , pp. 1124-1130
    • Gatward, J.J.1    Cook, T.M.2    Seller, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.