메뉴 건너뛰기




Volumn 87, Issue C, 2001, Pages 21-35

Accelerators for ultrafast phenomena

Author keywords

[No Author keywords available]

Indexed keywords


EID: 77957075255     PISSN: 01676881     EISSN: None     Source Type: Book Series    
DOI: 10.1016/S0167-6881(01)80004-5     Document Type: Article
Times cited : (27)

References (20)
  • 1
    • 33845211006 scopus 로고    scopus 로고
    • Ultrafast electron transfer and short-lived prereactive steps in solutions
    • Photochemistry and Radiation Chemistry: Complementary Methods for the Study of Electron Transfer. Wishart J.F., and Nocera D.G. (Eds), American Chemical Society, Washington, DC
    • Gauduel Y., and Gelabert H. Ultrafast electron transfer and short-lived prereactive steps in solutions. In: Wishart J.F., and Nocera D.G. (Eds). Photochemistry and Radiation Chemistry: Complementary Methods for the Study of Electron Transfer. Adv. Chem. Ser. 254, Ch. 6 (1998), American Chemical Society, Washington, DC 331
    • (1998) Adv. Chem. Ser. 254, Ch. 6 , pp. 331
    • Gauduel, Y.1    Gelabert, H.2
  • 2
    • 0000888812 scopus 로고    scopus 로고
    • Detailed Investigation of the Femtosecond Pump-Probe Spectroscopy of the Hydrated Electron
    • Yokoyama K., Silva C., Son D.-H., Walhout P.K., and Barbara P.F. Detailed Investigation of the Femtosecond Pump-Probe Spectroscopy of the Hydrated Electron. J. Phys. Chem. A 102 (1998) 6957
    • (1998) J. Phys. Chem. A , vol.102 , pp. 6957
    • Yokoyama, K.1    Silva, C.2    Son, D.-H.3    Walhout, P.K.4    Barbara, P.F.5
  • 7
    • 0032047201 scopus 로고    scopus 로고
    • Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera
    • Uesaka M., Ueda T., Kozawa T., and Kobayashi T. Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera. Nucl. Inst. Meth. Phys. Res. A 406 (1998) 371
    • (1998) Nucl. Inst. Meth. Phys. Res. A , vol.406 , pp. 371
    • Uesaka, M.1    Ueda, T.2    Kozawa, T.3    Kobayashi, T.4
  • 8
    • 0016916828 scopus 로고
    • Optimization of isolated electron pulses in the picosecond range from a linear accelerator using a streak camera-TV diagnostic system
    • Mavrogenes G.S., Jonah C., Schmidt K.H., Gordon S., Tripp G.R., and Coleman L.W. Optimization of isolated electron pulses in the picosecond range from a linear accelerator using a streak camera-TV diagnostic system. Rev. Sci. Instrum. 47 (1976) 187
    • (1976) Rev. Sci. Instrum. , vol.47 , pp. 187
    • Mavrogenes, G.S.1    Jonah, C.2    Schmidt, K.H.3    Gordon, S.4    Tripp, G.R.5    Coleman, L.W.6
  • 11
    • 0032093968 scopus 로고    scopus 로고
    • Bunch length measurement of picosecond electron beams from a photoinjector using coherent transition radiation
    • Murokh A., Rosenzweig J.B., Hogan M., Suk H., Travish G., and Happek U. Bunch length measurement of picosecond electron beams from a photoinjector using coherent transition radiation. Nucl. Inst. Meth. Phys. Res. A 410 (1998) 452
    • (1998) Nucl. Inst. Meth. Phys. Res. A , vol.410 , pp. 452
    • Murokh, A.1    Rosenzweig, J.B.2    Hogan, M.3    Suk, H.4    Travish, G.5    Happek, U.6
  • 15
    • 0030835225 scopus 로고    scopus 로고
    • Coherent Smith-Purcell radiation as a pulse length diagnostic
    • D. C. Nguyen, Electron bunch length diagnostic with coherent Smith-Purcell radiation, Proceedings of the 1998 European Particle Accelerator Conference (EPAC 98) page 1990
    • D. C. Nguyen, Electron bunch length diagnostic with coherent Smith-Purcell radiation, Proceedings of the 1998 European Particle Accelerator Conference (EPAC 98) page 1990. Lampel M.C. Coherent Smith-Purcell radiation as a pulse length diagnostic. Nucl. Inst. Meth. Phys. Res. A 385 (1997) 19
    • (1997) Nucl. Inst. Meth. Phys. Res. A , vol.385 , pp. 19
    • Lampel, M.C.1
  • 16
    • 0343022675 scopus 로고
    • A pulse-radiolysis system for the observation of short-lived transients
    • Bronskill M.J., and Hunt J.W. A pulse-radiolysis system for the observation of short-lived transients. J. Phys. Chem. 72 (1968) 3762
    • (1968) J. Phys. Chem. , vol.72 , pp. 3762
    • Bronskill, M.J.1    Hunt, J.W.2
  • 17
    • 0014744343 scopus 로고
    • Design and performance of a pulse radiolysis system capable of picosecond time resolution
    • Bronskill M.J., Taylor W.B., Wolff R.K., and Hunt J.W. Design and performance of a pulse radiolysis system capable of picosecond time resolution. Rev. Sci. Instrum. 41 (1970) 333
    • (1970) Rev. Sci. Instrum. , vol.41 , pp. 333
    • Bronskill, M.J.1    Taylor, W.B.2    Wolff, R.K.3    Hunt, J.W.4
  • 18
    • 0016431347 scopus 로고
    • A wide-time range pulse radiolysis system of picosecond time resolution
    • Jonah C.D. A wide-time range pulse radiolysis system of picosecond time resolution. Rev. Sci. Instrum. 46 (1975) 62
    • (1975) Rev. Sci. Instrum. , vol.46 , pp. 62
    • Jonah, C.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.