메뉴 건너뛰기




Volumn 11, Issue 3, 2010, Pages 225-230

Dosimetric comparison of various optimization techniques for high dose rate brachytherapy of interstitial cervix implants

Author keywords

High dose rate; Interstitial implant; Isodose reshape; Optimization; Target coverage

Indexed keywords


EID: 77957010991     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v11i3.3227     Document Type: Article
Times cited : (17)

References (11)
  • 1
    • 67349083254 scopus 로고    scopus 로고
    • High-dose-rate interstitial brachytherapy for previously untreated cervical carcinoma
    • Isohashi F, Yoshioka Y, Koizumi M, et al. High-dose-rate interstitial brachytherapy for previously untreated cervical carcinoma. Brachytherapy. 2009;8(2):234-39.
    • (2009) Brachytherapy , vol.8 , Issue.2 , pp. 234-239
    • Isohashi, F.1    Yoshioka, Y.2    Koizumi, M.3
  • 3
    • 0026099661 scopus 로고
    • Quantitative assessment of interstitial implants
    • Saw CB, Suntharalingam N. Quantitative assessment of interstitial implants. Int J Radiat Oncol Biol Phys. 1991;20(1):135-39.
    • (1991) Int J Radiat Oncol Biol Phys , vol.20 , Issue.1 , pp. 135-139
    • Saw, C.B.1    Suntharalingam, N.2
  • 4
    • 39449113056 scopus 로고    scopus 로고
    • A comparison of anatomy-based inverse planning with simulated annealing and graphical optimization for high-dose-rate prostate brachytherapy
    • Morton GC, Sankreacha R, Halina P, Loblaw A. A comparison of anatomy-based inverse planning with simulated annealing and graphical optimization for high-dose-rate prostate brachytherapy. Brachytherapy. 2008;7(1):12-16.
    • (2008) Brachytherapy , vol.7 , Issue.1 , pp. 12-16
    • Morton, G.C.1    Sankreacha, R.2    Halina, P.3    Loblaw, A.4
  • 5
    • 33746870076 scopus 로고    scopus 로고
    • Dosimetric comparison of inverse optimization with geometric optimization in combination with graphical optimization for HDR prostate implants
    • Jamema SV, Saju S, Shetty UM, Pallad S, Deshpande DD, Shrivastava SK. Dosimetric comparison of inverse optimization with geometric optimization in combination with graphical optimization for HDR prostate implants. J Med Phys. 2006;31(2):89-94.
    • (2006) J Med Phys , vol.31 , Issue.2 , pp. 89-94
    • Jamema, S.V.1    Saju, S.2    Shetty, U.M.3    Pallad, S.4    Deshpande, D.D.5    Shrivastava, S.K.6
  • 6
    • 33645341440 scopus 로고    scopus 로고
    • Anatomy-based inverse optimization in high-dose-rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer: comparison of incidence of acute genitourinary toxicity between anatomy-based inverse optimization and geometric optimization
    • Akimoto T, Katoh H, Kitamoto Y, Shirai K, Shioya M, Nakano T. Anatomy-based inverse optimization in high-dose-rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer: comparison of incidence of acute genitourinary toxicity between anatomy-based inverse optimization and geometric optimization. Int J Radiat Oncol Biol Phys. 2006;64(5):1360-66.
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , Issue.5 , pp. 1360-1366
    • Akimoto, T.1    Katoh, H.2    Kitamoto, Y.3    Shirai, K.4    Shioya, M.5    Nakano, T.6
  • 7
    • 85024402728 scopus 로고    scopus 로고
    • Treatment planning BrachyVision Version 6.5 - Instructions for use. Palo Alto, CA: Varian Medical Systems. Version 8.0 available from
    • Treatment planning BrachyVision Version 6.5 - Instructions for use. Palo Alto, CA: Varian Medical Systems; 2004. Version 8.0 available from: www.varian.com/media/oncology/brachytherapy/brachyvision-8.0-2006.pdf.
    • (2004)
  • 8
    • 0032518595 scopus 로고
    • A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy
    • Baltas D, Kolotas C, Geramani K, et al. A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy. Int J Radiat Oncol Biol Phys. 1988;40(2):515-24.
    • (1988) Int J Radiat Oncol Biol Phys , vol.40 , Issue.2 , pp. 515-524
    • Baltas, D.1    Kolotas, C.2    Geramani, K.3
  • 9
    • 0023883007 scopus 로고
    • A dose homogeneity index for evaluating Ir-192 interstitial breast implants
    • Wu A, Ulin K, Sternick ES. A dose homogeneity index for evaluating Ir-192 interstitial breast implants. Med Phys. 1988;15:104-107.
    • (1988) Med Phys , vol.15 , pp. 104-107
    • Wu, A.1    Ulin, K.2    Sternick, E.S.3
  • 10
    • 33846646460 scopus 로고    scopus 로고
    • Multi-species prostate implant treatment plans incorporating 192Ir and 125I using a Greedy Heuristic based 3D optimization algorithm
    • Chaswal V, Yoo S, Thomadsen BR, Henderson DL. Multi-species prostate implant treatment plans incorporating 192Ir and 125I using a Greedy Heuristic based 3D optimization algorithm. Med Phys. 2007;34(2):436-44.
    • (2007) Med Phys , vol.34 , Issue.2 , pp. 436-444
    • Chaswal, V.1    Yoo, S.2    Thomadsen, B.R.3    Henderson, D.L.4
  • 11
    • 0034562790 scopus 로고    scopus 로고
    • The combined use of the natural and the cumulative dose-volume histograms in planning and evaluation of permanent prostatic seed implants
    • Moerland MA, van der Laarse R, Luthmann RW, Wijrdeman HK, Battermann JJ. The combined use of the natural and the cumulative dose-volume histograms in planning and evaluation of permanent prostatic seed implants. Radiother Oncol. 2000;57(3):279-84.
    • (2000) Radiother Oncol , vol.57 , Issue.3 , pp. 279-284
    • Moerland, M.A.1    van der Laarse, R.2    Luthmann, R.W.3    Wijrdeman, H.K.4    Battermann, J.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.