메뉴 건너뛰기




Volumn 24, Issue 5, 2010, Pages 653-659

Optimizing ICD programming for shock reduction

Author keywords

device programming; implantable cardioverter defibrillator (ICD); shock reduction; ventricular tachyarrhythmia

Indexed keywords

CARDIAC PATIENT; CLINICAL TRIAL; CONVULSIVE THERAPY; DEFIBRILLATOR; DEPRESSION; HEART ATRIUM FIBRILLATION; HEART FAILURE; HEART PACING; HEART VENTRICLE ARRHYTHMIA; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HOSPITAL ADMISSION; HOSPITALIZATION; HUMAN; MONOMORPHIC VENTRICULAR TACHYCARDIA; PHYSICIAN; PRIMARY PREVENTION; PRIORITY JOURNAL; PROCESS OPTIMIZATION; QUALITY OF LIFE; REVIEW; SECONDARY PREVENTION; SHOCK; SUPRAVENTRICULAR TACHYCARDIA;

EID: 77957000401     PISSN: 07673981     EISSN: 14728206     Source Type: Journal    
DOI: 10.1111/j.1472-8206.2010.00868.x     Document Type: Review
Times cited : (5)

References (11)
  • 1
    • 33749239027 scopus 로고    scopus 로고
    • ACC/AHA/ESC 2006 Guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines
    • Zipes D., Camm A., Borggrefe M. et al. ACC/AHA/ESC 2006 Guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death) developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Europace (2006) 8 746 837.
    • (2006) Europace , vol.8 , pp. 746-837
    • Zipes, D.1    Camm, A.2    Borggrefe, M.3
  • 2
    • 0035859949 scopus 로고    scopus 로고
    • Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease
    • Wathen M.S., Sweeney M., DeGroot P.J. et al. Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease. Circulation (2001) 104 796 801.
    • (2001) Circulation , vol.104 , pp. 796-801
    • Wathen, M.S.1    Sweeney, M.2    Degroot, P.J.3
  • 3
    • 7544220287 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators pacing fast ventricular tachycardia reduces shock therapies (PainFREE Rx II) trial results
    • Wathen M.S., DeGroot P.J., Sweeney M.O. et al. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators pacing fast ventricular tachycardia reduces shock therapies (PainFREE Rx II) trial results. Circulation (2004) 110 2591 2596.
    • (2004) Circulation , vol.110 , pp. 2591-2596
    • Wathen, M.S.1    Degroot, P.J.2    Sweeney, M.O.3
  • 4
    • 34250745334 scopus 로고    scopus 로고
    • Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: Antitachycardia pacing therapy during charging
    • Schoels W., Steinhaus D., Johnson W.B. et al. Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging. Heart Rhythm (2007) 4 879 885.
    • (2007) Heart Rhythm , vol.4 , pp. 879-885
    • Schoels, W.1    Steinhaus, D.2    Johnson, W.B.3
  • 5
    • 66649114662 scopus 로고    scopus 로고
    • Termination of fast ventricular tachyarrhythmia by antitachycardia pacing in patients with implantable cardioverter-defibrillators: Comparison of the results of the entrust clinical study with the PainFREE RX II study
    • (abstract).
    • Schwab J.O., Steinhaus D., Schöls W. et al. Termination of fast ventricular tachyarrhythmia by antitachycardia pacing in patients with implantable cardioverter-defibrillators: comparison of the results of the entrust clinical study with the PainFREE RX II study. Circulation (2005) 112 (Suppl II) 374 (abstract).
    • (2005) Circulation , vol.112 , Issue.SUPPL. II , pp. 374
    • Schwab, J.O.1    Steinhaus, D.2    Schöls, W.3
  • 6
    • 33745685677 scopus 로고    scopus 로고
    • A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: Results from the prospective randomized multicenter EMPIRIC trial
    • Wilkoff B.L., Ousdigian K.T., Sterns L.D. et al. A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: results from the prospective randomized multicenter EMPIRIC trial. J. Am. Coll. Cardiol. (2006) 48 330 339.
    • (2006) J. Am. Coll. Cardiol , vol.48 , pp. 330-339
    • Wilkoff, B.L.1    Ousdigian, K.T.2    Sterns, L.D.3
  • 7
    • 0035490436 scopus 로고    scopus 로고
    • Clinical performance of a specific algorithm to reconfirm self-terminating ventricular arrhythmias in current implantable cardioverter-defibrillators
    • Raedle-Hurst T.M., Wiecha J., Schwab J.O. et al. Clinical performance of a specific algorithm to reconfirm self-terminating ventricular arrhythmias in current implantable cardioverter-defibrillators. Am. J. Cardiol. (2001) 88 744 749.
    • (2001) Am. J. Cardiol , vol.88 , pp. 744-749
    • Raedle-Hurst, T.M.1    Wiecha, J.2    Schwab, J.O.3
  • 8
    • 48449088263 scopus 로고    scopus 로고
    • Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: Results from the PREPARE (Primary Prevention Parameters Evaluation) study
    • Wilkoff B.L., Williamson B.D., Stern R.S. et al. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study. J. Am. Coll. Cardiol. (2008) 52 541 545.
    • (2008) J. Am. Coll. Cardiol , vol.52 , pp. 541-545
    • Wilkoff, B.L.1    Williamson, B.D.2    Stern, R.S.3
  • 9
    • 72949114097 scopus 로고    scopus 로고
    • A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention.
    • Gasparini M., Menozzi C., Proclemer A. et al. A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study. Eur. Heart J. (2009) 30 2758 2767.
    • (2009) Eur. Heart J , vol.30 , pp. 2758-2767
    • Gasparini, M.1    Menozzi, C.2    Proclemer, A.3
  • 10
    • 77957000825 scopus 로고    scopus 로고
    • Virtual ICD: A model to evaluate shock reduction strategies
    • Volosin K.J., Exner D.V., Wathen M.S. et al. Virtual ICD: a model to evaluate shock reduction strategies. Heart Rhythm (2010) 5 (Suppl.) P03 P125.
    • (2010) Heart Rhythm , vol.5 , Issue.SUPPL.
    • Volosin, K.J.1    Exner, D.V.2    Wathen, M.S.3
  • 11
    • 66649134745 scopus 로고    scopus 로고
    • Avoid delivering therapies for nonsustained fast ventricular tachyarrhythmia in patients with implantable cardioverter/defibrillator: The ADVANCE III Trial
    • Schwab J.O., Gasparini M., Lunati M. et al. Avoid delivering therapies for nonsustained fast ventricular tachyarrhythmia in patients with implantable cardioverter/defibrillator: the ADVANCE III Trial. J. Cardiovasc. Electrophysiol. (2009) 20 663 666.
    • (2009) J. Cardiovasc. Electrophysiol , vol.20 , pp. 663-666
    • Schwab, J.O.1    Gasparini, M.2    Lunati, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.