Volumn 61, Issue 2, 2010, Pages 231-233

Simple, inexpensive attainment and measurement of very high cooling and warming rates

Author keywords

Cooling; Cryotop; High rate; Inexpensive temperature measurement; Type T thermocouple; USB oscilloscope; Warming

Indexed keywords

ICE; METAL; POLYPROPYLENE;

EID: 77956937779     PISSN: 00112240     EISSN: 10902392     Source Type: Journal    
DOI: 10.1016/j.cryobiol.2010.06.011     Document Type: Article
Times cited : (28)

References (8)
  • 1
    • 77956902635 scopus 로고    scopus 로고
    • Hillsboro, Oregon, USA
    • EasySync Ltd., Hillsboro, Oregon, USA,http://www.easysync-ltd.com/.
    • EasySync Ltd.
  • 2
    • 77956924352 scopus 로고    scopus 로고
    • Japan
    • Kitazato Biopharma, Japan,http://www.kitazato-biopharma.com/cryotop/method.html.
    • Kitazato Biopharma
  • 3
    • 77956935165 scopus 로고    scopus 로고
    • Abstract presented at Cryo-2009: simple, inexpensive measurement of very rapid cooling and warming rates
    • Kleinhans F.W., Seki S., Mazur P. Abstract presented at Cryo-2009: simple, inexpensive measurement of very rapid cooling and warming rates. Cryobiology 2009, 59:381.
    • (2009) Cryobiology , vol.59 , pp. 381
    • Kleinhans, F.W.1    Seki, S.2    Mazur, P.3
  • 4
    • 24644455926 scopus 로고    scopus 로고
    • Highly efficient vitrification method for cryopreservation of human oocytes
    • Kuwayama M. Highly efficient vitrification method for cryopreservation of human oocytes. Reproductive BioMedicine Online 2005, 11:300-308.
    • (2005) Reproductive BioMedicine Online , vol.11 , pp. 300-308
    • Kuwayama, M.1
  • 5
    • 77956902917 scopus 로고    scopus 로고
    • Abstract presented at Cryo-2009: survival of mouse oocytes suspended in EAFS 10/10 vitrification solution after being cooled to -196°C on Cryotops at rates ranging from 95°C/min to 70,000°C/min and warmed at 610°C/min to 118,000°C/min
    • Mazur P., Seki S., Kleinhans F.W. Abstract presented at Cryo-2009: survival of mouse oocytes suspended in EAFS 10/10 vitrification solution after being cooled to -196°C on Cryotops at rates ranging from 95°C/min to 70,000°C/min and warmed at 610°C/min to 118,000°C/min. Cryobiology 2009, 59:396.
    • (2009) Cryobiology , vol.59 , pp. 396
    • Mazur, P.1    Seki, S.2    Kleinhans, F.W.3
  • 6
    • 84874443450 scopus 로고    scopus 로고
    • Stamford, Connecticut, USA,The 50μm wire Type T thermocouple is part # COCO-002. I.e. Copper-Constantan 0.002" wire thermocouple
    • Omega Engineering Inc., Stamford, Connecticut, USA,The 50μm wire Type T thermocouple is part # COCO-002. I.e. Copper-Constantan 0.002" wire thermocouple. http://www.omega.com/.
    • Omega Engineering Inc.
  • 7
    • 84874443450 scopus 로고    scopus 로고
    • Stamford, Connecticut, USA. These response data appear on the web order page for " Unsheathed Fine Gage Microtemp Thermocouples, J, K, T, E, R &S" ; specifically
    • Omega Engineering Inc., Stamford, Connecticut, USA. These response data appear on the web order page for " Unsheathed Fine Gage Microtemp Thermocouples, J, K, T, E, R &S" ; specifically,http://www.omega.com/ppt/pptsc.asp?ref=IRCO_CHAL_P13R_P10R&Nav=tema02.
    • Omega Engineering Inc.
  • 8
    • 67649404589 scopus 로고    scopus 로고
    • The dominance of warming rate over cooling rate in the survival of mouse oocytes subjected to a vitrification procedure
    • Seki S., Mazur P. The dominance of warming rate over cooling rate in the survival of mouse oocytes subjected to a vitrification procedure. Cryobiology 2009, 59:75-82.
    • (2009) Cryobiology , vol.59 , pp. 75-82
    • Seki, S.1    Mazur, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.