-
1
-
-
33750313558
-
Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis
-
Sun Z, Jiang W. Diagnostic value of multislice computed tomography angiography in coronary artery disease: a meta-analysis. Eur J Radiol 2006;60:79-86.
-
(2006)
Eur J Radiol
, vol.60
, pp. 79-86
-
-
Sun, Z.1
Jiang, W.2
-
2
-
-
34848867564
-
Cardiac CT: State of the art for the detection of coronary arterial stenosis
-
Achenbach S. Cardiac CT: state of the art for the detection of coronary arterial stenosis. J Cardiovasc Comput Tomogr 2007;1:3-20.
-
(2007)
J Cardiovasc Comput Tomogr
, vol.1
, pp. 3-20
-
-
Achenbach, S.1
-
3
-
-
31144447047
-
Usefulness of multidetector row spiral computed tomography with 64- 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses
-
Ropers D, Rixe J, Anders K, Ku?ttner A, Baum U, Bautz W, Daniel WG, Achenbach S. Usefulness of multidetector row spiral computed tomography with 64- ? 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol 2006;97:343-348.
-
(2006)
Am J Cardiol
, vol.97
, pp. 343-348
-
-
Ropers, D.1
Rixe, J.2
Anders, K.3
Küttner, A.4
Baum, U.5
Bautz, W.6
Daniel, W.G.7
Achenbach, S.8
-
4
-
-
33747121014
-
Accuracy of 64-MDCT in the diagnosis of ischemic heart disease
-
Nikolaou K, Knez A, Rist C, Wintersperger BJ, Leber A, Johnson T, Reiser MF, Becker CR. Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR Am J Roentgenol 2006;187:111-117.
-
(2006)
AJR Am J Roentgenol
, vol.187
, pp. 111-117
-
-
Nikolaou, K.1
Knez, A.2
Rist, C.3
Wintersperger, B.J.4
Leber, A.5
Johnson, T.6
Reiser, M.F.7
Becker, C.R.8
-
5
-
-
33751574663
-
Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation
-
Ropers D, Pohle FK, Kuettner A, Pflederer T, Anders K, Daniel WG, Bautz W, Baum U, Achenbach S. Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation. Circulation 2006;114:2334-2341.
-
(2006)
Circulation
, vol.114
, pp. 2334-2341
-
-
Ropers, D.1
Pohle, F.K.2
Kuettner, A.3
Pflederer, T.4
Anders, K.5
Daniel, W.G.6
Bautz, W.7
Baum, U.8
Achenbach, S.9
-
6
-
-
35148867562
-
Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
-
Leber AW, Johnson T, Becker A, von Ziegler F, Tittus J, Nikolaou K, Reiser M, Steinbeck G, Becker CR, Knez A. Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J 2007;28:2354-2360.
-
(2007)
Eur Heart J
, vol.28
, pp. 2354-2360
-
-
Leber, A.W.1
Johnson, T.2
Becker, A.3
Von Ziegler, F.4
Tittus, J.5
Nikolaou, K.6
Reiser, M.7
Steinbeck, G.8
Becker, C.R.9
Knez, A.10
-
7
-
-
41349096091
-
Randomized Comparison of 64-Slice Single- and Dual-Source Computed Tomography Coronary Angiography for the Detection of Coronary Artery Disease
-
DOI 10.1016/j.jcmg.2007.11.006, PII S1936878X08000090
-
Achenbach S, Ropers U, Kuettner A, Anders K, Pflederer T, Komatsu S, Bautz W, Daniel WG, Ropers D. Randomized comparison of 64-slice single- and dualsource computed tomography coronary angiography for the detection of coronary artery disease. JACC Cardiovasc Imaging 2008;1:177-186. (Pubitemid 351447183)
-
(2008)
JACC: Cardiovascular Imaging
, vol.1
, Issue.2
, pp. 177-186
-
-
Achenbach, S.1
Ropers, U.2
Kuettner, A.3
Anders, K.4
Pflederer, T.5
Komatsu, S.6
Bautz, W.7
Daniel, W.G.8
Ropers, D.9
-
8
-
-
37449003958
-
Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography
-
DOI 10.1016/j.jacc.2007.09.017, PII S0735109707031117
-
Ropers U, Ropers D, Pflederer T, Anders K, Kuettner A, Stilianakis NI, Komatsu S, Kalender W, Bautz W, Daniel WG, Achenbach S. Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 2007;50:2393-2398. (Pubitemid 50011578)
-
(2007)
Journal of the American College of Cardiology
, vol.50
, Issue.25
, pp. 2393-2398
-
-
Ropers, U.1
Ropers, D.2
Pflederer, T.3
Anders, K.4
Kuettner, A.5
Stilianakis, N.I.6
Komatsu, S.7
Kalender, W.8
Bautz, W.9
Daniel, W.G.10
Achenbach, S.11
-
9
-
-
41149084470
-
Dual-source computed tomography coronary angiography: Influence of obesity, calcium load, and heart rate on diagnostic accuracy
-
Alkadhi H, Scheffel H, Desbiolles L, Gaemperli O, Stolzmann P, Plass A, Goerres GW, Luescher TF, Genoni M, Marincek B, Kaufmann PA, Leschka S. Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy. Eur Heart J 2008;29:766-776.
-
(2008)
Eur Heart J
, vol.29
, pp. 766-776
-
-
Alkadhi, H.1
Scheffel, H.2
Desbiolles, L.3
Gaemperli, O.4
Stolzmann, P.5
Plass, A.6
Goerres, G.W.7
Luescher, T.F.8
Genoni, M.9
Marincek, B.10
Kaufmann, P.A.11
Leschka, S.12
-
10
-
-
56349113761
-
Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with singlesource CT
-
Wang Y, Zhang Z, Kong L, Song L, Merges RD, Chen J, Jin Z. Dual-source CT coronary angiography in patients with atrial fibrillation: comparison with singlesource CT. Eur J Radiol 2008;68:434-441.
-
(2008)
Eur J Radiol
, vol.68
, pp. 434-441
-
-
Wang, Y.1
Zhang, Z.2
Kong, L.3
Song, L.4
Merges, R.D.5
Chen, J.6
Jin, Z.7
-
11
-
-
43449087618
-
Dual-source cardiac computed tomography: Image quality and dose considerations
-
Achenbach S, Anders K, Kalender WA. Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 2008;18:1188-1198.
-
(2008)
Eur Radiol
, vol.18
, pp. 1188-1198
-
-
Achenbach, S.1
Anders, K.2
Kalender, W.A.3
-
12
-
-
34447338023
-
Image quality and reconstruction intervals of dual-source CT coronary angiography: Recommendations for ECG-pulsing windowing
-
Leschka S, Scheffel H, Desbiolles L, Plass A, Gaemperli O, Valenta I, Husmann L, Flohr TG, Genoni M, Marincek B, Kaufmann PA, Alkadhi H. Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 2007;42:543-549.
-
(2007)
Invest Radiol
, vol.42
, pp. 543-549
-
-
Leschka, S.1
Scheffel, H.2
Desbiolles, L.3
Plass, A.4
Gaemperli, O.5
Valenta, I.6
Husmann, L.7
Flohr, T.G.8
Genoni, M.9
Marincek, B.10
Kaufmann, P.A.11
Alkadhi, H.12
-
13
-
-
44449098165
-
Dual-source CT: Effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy
-
Brodoefel H, Burgstahler C, Tsiflikas I, Reimann A, Schroeder S, Claussen CD, Heuschmid M, Kopp AF. Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 2008;247: 346-355.
-
(2008)
Radiology
, vol.247
, pp. 346-355
-
-
Brodoefel, H.1
Burgstahler, C.2
Tsiflikas, I.3
Reimann, A.4
Schroeder, S.5
Claussen, C.D.6
Heuschmid, M.7
Kopp, A.F.8
-
14
-
-
36249014925
-
Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: Initial experience
-
Oncel D, Oncel G, Tastan A. Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: initial experience. Radiology 2007;245:703-711.
-
(2007)
Radiology
, vol.245
, pp. 703-711
-
-
Oncel, D.1
Oncel, G.2
Tastan, A.3
-
15
-
-
67651018756
-
Noninvasive coronary angiography using dual-source computed tomography in patients with atrial fibrillation
-
Rist C, Johnson TR, Müller-Starck J, Arnoldi E, Saam T, Becker A, Leber AW, Wintersperger BJ, Becker CR, Reiser MF, Nikolaou K. Noninvasive coronary angiography using dual-source computed tomography in patients with atrial fibrillation. Invest Radiol 2009;44:159-167.
-
(2009)
Invest Radiol
, vol.44
, pp. 159-167
-
-
Rist, C.1
Johnson, T.R.2
Müller-Starck, J.3
Arnoldi, E.4
Saam, T.5
Becker, A.6
Leber, A.W.7
Wintersperger, B.J.8
Becker, C.R.9
Reiser, M.F.10
Nikolaou, K.11
-
16
-
-
77956942761
-
-
March 2004. Contract No. FIGM-CT2000-20078-CT-TIP (12 January 2009)
-
BongartzG,Golding SJ, Jurik AG, LeonardiM, van Persijn van Meerten E, Rodriguez R, Schneider K, Calzado A, Geleijns J, Jessen KA, Panzer W. European Guidelines for Multislice Computed Tomography: Appendix C. Funded by the European Commission; March 2004. Contract No. FIGM-CT2000-20078-CT-TIP. http:// www.msct.eu/PDF-FILES/EC%20CA%20Report%20D5%20-%20Dosimetry.pdf (12 January 2009).
-
European Guidelines for Multislice Computed Tomography: Appendix C. Funded by the European Commission
-
-
Bongartzggolding, S.J.1
Jurik, A.G.2
Leonardim Van Persijn Van Meerten, E.3
Rodriguez, R.4
Schneider, K.5
Calzado, A.6
Geleijns, J.7
Jessen, K.A.8
Panzer, W.9
-
17
-
-
16044368012
-
Statistical methodology: I. Incorporating the prevalence of disease into the sample size calculation for sensitivity and specificity
-
Buderer NM. Statistical methodology: I. Incorporating the prevalence of disease into the sample size calculation for sensitivity and specificity. Acad Emerg Med 1996;3:895-900.
-
(1996)
Acad Emerg Med
, vol.3
, pp. 895-900
-
-
Buderer, N.M.1
-
18
-
-
18844395876
-
Sensitivity, specificity and other diagnostic measures with multiple sites per unit
-
Drake C, Levine RA. Sensitivity, specificity and other diagnostic measures with multiple sites per unit. Contemp Clin Trials 2005;26:252-259.
-
(2005)
Contemp Clin Trials
, vol.26
, pp. 252-259
-
-
Drake, C.1
Levine, R.A.2
-
19
-
-
84946650481
-
Probable inference, the law of succession, and statistical inference
-
Wilson EB. Probable inference, the law of succession, and statistical inference. J Am Stat Assoc 22:209-212.
-
J Am Stat Assoc
, vol.22
, pp. 209-212
-
-
Wilson, E.B.1
-
20
-
-
0018750969
-
Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease
-
Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. N Engl J Med 1979;300:1350-1358.
-
(1979)
N Engl J Med
, vol.300
, pp. 1350-1358
-
-
Diamond, G.A.1
Forrester, J.S.2
-
21
-
-
33645822745
-
Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing
-
Cademartiri F, Mollet NR, Runza G, Baks T, Midiri M, McFadden EP, Flohr TG, Ohnesorge B, de Feyter PJ, Krestin GP. Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing. AJR Am J Roentgenol 2006;186:634-638.
-
(2006)
AJR Am J Roentgenol
, vol.186
, pp. 634-638
-
-
Cademartiri, F.1
Mollet, N.R.2
Runza, G.3
Baks, T.4
Midiri, M.5
McFadden, E.P.6
Flohr, T.G.7
Ohnesorge, B.8
De Feyter, P.J.9
Krestin, G.P.10
-
22
-
-
44049096704
-
Dual-source coronary computed tomography angiography in patients with atrial fibrillation: Initial experience
-
Wolak A, Gutstein A, Cheng VY, Suzuki Y, Thomson LE, Friedman J, Dey D, Hayes SW, Slomka PJ, Germano G, Berman DS. Dual-source coronary computed tomography angiography in patients with atrial fibrillation: initial experience. J Cardiovasc Comput Tomogr 2008;2:172-180.
-
(2008)
J Cardiovasc Comput Tomogr
, vol.2
, pp. 172-180
-
-
Wolak, A.1
Gutstein, A.2
Cheng, V.Y.3
Suzuki, Y.4
Thomson, L.E.5
Friedman, J.6
Dey, D.7
Hayes, S.W.8
Slomka, P.J.9
Germano, G.10
Berman, D.S.11
-
23
-
-
70349611312
-
First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography
-
Herzog BA, Wyss CA, Husmann L, Gaemperli O, Valenta I, Treyer V, Landmesser U, Kaufmann PA. First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography. Heart 2009;95:1656-1661.
-
(2009)
Heart
, vol.95
, pp. 1656-1661
-
-
Herzog, B.A.1
Wyss, C.A.2
Husmann, L.3
Gaemperli, O.4
Valenta, I.5
Treyer, V.6
Landmesser, U.7
Kaufmann, P.A.8
|