-
1
-
-
0035950239
-
Human ocular dominance columns as revealed by high-field functional magnetic resonance imaging
-
Cheng K., Waggoner R.A., Tanaka K. Human ocular dominance columns as revealed by high-field functional magnetic resonance imaging. Neuron 2001, 32(2):359-374.
-
(2001)
Neuron
, vol.32
, Issue.2
, pp. 359-374
-
-
Cheng, K.1
Waggoner, R.A.2
Tanaka, K.3
-
2
-
-
34548534644
-
Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 Tesla
-
Yacoub E., Shmuel A., Logothetis N., Ugurbil K. Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 Tesla. Neuroimage 2007, 37(4):1161-1177.
-
(2007)
Neuroimage
, vol.37
, Issue.4
, pp. 1161-1177
-
-
Yacoub, E.1
Shmuel, A.2
Logothetis, N.3
Ugurbil, K.4
-
3
-
-
33646149376
-
Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fMRI: insights into hemodynamic regulation
-
Zhao F., Wang P., Hendrich K., Ugurbil K., Kim S.G. Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fMRI: insights into hemodynamic regulation. Neuroimage 2006, 30(4):1149-1160.
-
(2006)
Neuroimage
, vol.30
, Issue.4
, pp. 1149-1160
-
-
Zhao, F.1
Wang, P.2
Hendrich, K.3
Ugurbil, K.4
Kim, S.G.5
-
4
-
-
31044443991
-
Combined imaging-histological study of cortical laminar specificity of fMRI signals
-
Harel N., Lin J., Moeller S., Ugurbil K., Yacoub E. Combined imaging-histological study of cortical laminar specificity of fMRI signals. Neuroimage 2006, 29(3):879-887.
-
(2006)
Neuroimage
, vol.29
, Issue.3
, pp. 879-887
-
-
Harel, N.1
Lin, J.2
Moeller, S.3
Ugurbil, K.4
Yacoub, E.5
-
5
-
-
0037130448
-
Ultra high-resolution fMRI in monkeys with implanted RF coils
-
Logothetis N.K., Merkle H., Augath M., Trinath T., Ugurbil K. Ultra high-resolution fMRI in monkeys with implanted RF coils. Neuron 2002, 35(2):227-242.
-
(2002)
Neuron
, vol.35
, Issue.2
, pp. 227-242
-
-
Logothetis, N.K.1
Merkle, H.2
Augath, M.3
Trinath, T.4
Ugurbil, K.5
-
7
-
-
0037069442
-
Laminar specificity of functional MRI onset times during somatosensory stimulation in rat
-
Silva A.C., Koretsky A.P. Laminar specificity of functional MRI onset times during somatosensory stimulation in rat. Proc Natl Acad Sci U S A 2002, 99(23):15182-15187.
-
(2002)
Proc Natl Acad Sci U S A
, vol.99
, Issue.23
, pp. 15182-15187
-
-
Silva, A.C.1
Koretsky, A.P.2
-
8
-
-
0036708143
-
Mapping at glomerular resolution: fMRI of rat olfactory bulb
-
Kida I., Xu F., Shulman R.G., Hyder F. Mapping at glomerular resolution: fMRI of rat olfactory bulb. Magn Reson Med 2002, 48(3):570-576.
-
(2002)
Magn Reson Med
, vol.48
, Issue.3
, pp. 570-576
-
-
Kida, I.1
Xu, F.2
Shulman, R.G.3
Hyder, F.4
-
9
-
-
33751252835
-
Structural and functional MRI reveals multiple retinal layers
-
Cheng H., Nair G., Walker T.A., Kim M.K., Pardue M.T., Thule P.M., et al. Structural and functional MRI reveals multiple retinal layers. Proc Natl Acad Sci U S A 2006, 103(46):17525-17530.
-
(2006)
Proc Natl Acad Sci U S A
, vol.103
, Issue.46
, pp. 17525-17530
-
-
Cheng, H.1
Nair, G.2
Walker, T.A.3
Kim, M.K.4
Pardue, M.T.5
Thule, P.M.6
-
10
-
-
43049104255
-
What we can do and what we cannot do with fMRI
-
Logothetis N.K. What we can do and what we cannot do with fMRI. Nature 2008, 453(7197):869-878.
-
(2008)
Nature
, vol.453
, Issue.7197
, pp. 869-878
-
-
Logothetis, N.K.1
-
11
-
-
39749185278
-
The effect of labeling parameters on perfusion-based fMRI in nonhuman primates
-
Zappe A.C., Pfeuffer J., Merkle H., Logothetis N.K., Goense J.B. The effect of labeling parameters on perfusion-based fMRI in nonhuman primates. J Cereb Blood Flow Metab 2008, 28(3):640-652.
-
(2008)
J Cereb Blood Flow Metab
, vol.28
, Issue.3
, pp. 640-652
-
-
Zappe, A.C.1
Pfeuffer, J.2
Merkle, H.3
Logothetis, N.K.4
Goense, J.B.5
-
12
-
-
0037381051
-
Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields
-
Yacoub E., Duong T.Q., Van de Moortele P.F., Lindquist M., Adriany G., Kim S.G., et al. Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields. Magn Reson Med 2003, 49(4):655-664.
-
(2003)
Magn Reson Med
, vol.49
, Issue.4
, pp. 655-664
-
-
Yacoub, E.1
Duong, T.Q.2
Van de Moortele, P.F.3
Lindquist, M.4
Adriany, G.5
Kim, S.G.6
-
13
-
-
33646133407
-
Laminar specificity in monkey V1 using high-resolution SE-fMRI
-
Goense J.B., Logothetis N.K. Laminar specificity in monkey V1 using high-resolution SE-fMRI. Magn Reson Imaging 2006, 24(4):381-392.
-
(2006)
Magn Reson Imaging
, vol.24
, Issue.4
, pp. 381-392
-
-
Goense, J.B.1
Logothetis, N.K.2
-
14
-
-
0025226022
-
The NMR phased array
-
Roemer P.B., Edelstein W.A., Hayes C.E., Souza S.P., Mueller O.M. The NMR phased array. Magn Reson Med 1990, 16(2):192-225.
-
(1990)
Magn Reson Med
, vol.16
, Issue.2
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
15
-
-
0031425055
-
Theory and application of array coils in MR spectroscopy
-
Wright S.M., Wald L.L. Theory and application of array coils in MR spectroscopy. NMR Biomed 1997, 10(8):394-410.
-
(1997)
NMR Biomed
, vol.10
, Issue.8
, pp. 394-410
-
-
Wright, S.M.1
Wald, L.L.2
-
16
-
-
33745685594
-
32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry
-
Wiggins G.C., Triantafyllou C., Potthast A., Reykowski A., Nittka M., Wald L.L. 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med 2006, 56(1):216-223.
-
(2006)
Magn Reson Med
, vol.56
, Issue.1
, pp. 216-223
-
-
Wiggins, G.C.1
Triantafyllou, C.2
Potthast, A.3
Reykowski, A.4
Nittka, M.5
Wald, L.L.6
-
17
-
-
4744373321
-
Large field-of-view real-time MRI with a 32-channel system
-
Hardy C.J., Darrow R.D., Saranathan M., Giaquinto R.O., Zhu Y., Dumoulin C.L., et al. Large field-of-view real-time MRI with a 32-channel system. Magn Reson Med 2004, 52(4):878-884.
-
(2004)
Magn Reson Med
, vol.52
, Issue.4
, pp. 878-884
-
-
Hardy, C.J.1
Darrow, R.D.2
Saranathan, M.3
Giaquinto, R.O.4
Zhu, Y.5
Dumoulin, C.L.6
-
19
-
-
69449091437
-
Wald LL. 96-Channel receive-only head coil for 3 Tesla: design optimization and evaluation
-
Wiggins G.C., Polimeni J.R., Potthast A., Schmitt M., Alagappan V. Wald LL. 96-Channel receive-only head coil for 3 Tesla: design optimization and evaluation. Magn Reson Med 2009, 62(3):754-762.
-
(2009)
Magn Reson Med
, vol.62
, Issue.3
, pp. 754-762
-
-
Wiggins, G.C.1
Polimeni, J.R.2
Potthast, A.3
Schmitt, M.4
Alagappan, V.5
-
20
-
-
4744340025
-
Highly parallel volumetric imaging with a 32-element RF coil array
-
Zhu Y., Hardy C.J., Sodickson D.K., Giaquinto R.O., Dumoulin C.L., Kenwood G., et al. Highly parallel volumetric imaging with a 32-element RF coil array. Magn Reson Med 2004, 52(4):869-877.
-
(2004)
Magn Reson Med
, vol.52
, Issue.4
, pp. 869-877
-
-
Zhu, Y.1
Hardy, C.J.2
Sodickson, D.K.3
Giaquinto, R.O.4
Dumoulin, C.L.5
Kenwood, G.6
-
21
-
-
33644842651
-
Phase compensation in single echo acquisition imaging. Phase effects of voxel-sized coils in planar and cylindrical arrays
-
McDougall M.P., Wright S.M. Phase compensation in single echo acquisition imaging. Phase effects of voxel-sized coils in planar and cylindrical arrays. IEEE Eng Med Biol Mag 2005, 24(6):17-22.
-
(2005)
IEEE Eng Med Biol Mag
, vol.24
, Issue.6
, pp. 17-22
-
-
McDougall, M.P.1
Wright, S.M.2
-
22
-
-
22744435455
-
64-channel array coil for single echo acquisition magnetic resonance imaging
-
McDougall M.P., Wright S.M. 64-channel array coil for single echo acquisition magnetic resonance imaging. Magn Reson Med 2005, 54(2):386-392.
-
(2005)
Magn Reson Med
, vol.54
, Issue.2
, pp. 386-392
-
-
McDougall, M.P.1
Wright, S.M.2
-
23
-
-
0036260602
-
Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging
-
de Zwart J.A., Ledden P.J., Kellman P., van Gelderen P., Duyn J.H. Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging. Magn Reson Med 2002, 47(6):1218-1227.
-
(2002)
Magn Reson Med
, vol.47
, Issue.6
, pp. 1218-1227
-
-
de Zwart, J.A.1
Ledden, P.J.2
Kellman, P.3
van Gelderen, P.4
Duyn, J.H.5
-
24
-
-
43049101984
-
Neurophysiology of the BOLD fMRI signal in awake monkeys
-
Goense J.B., Logothetis N.K. Neurophysiology of the BOLD fMRI signal in awake monkeys. Curr Biol 2008, 18(9):631-640.
-
(2008)
Curr Biol
, vol.18
, Issue.9
, pp. 631-640
-
-
Goense, J.B.1
Logothetis, N.K.2
-
25
-
-
0035849892
-
Neurophysiological investigation of the basis of the fMRI signal
-
Logothetis N.K., Pauls J., Augath M., Trinath T., Oeltermann A. Neurophysiological investigation of the basis of the fMRI signal. Nature 2001, 412(6843):150-157.
-
(2001)
Nature
, vol.412
, Issue.6843
, pp. 150-157
-
-
Logothetis, N.K.1
Pauls, J.2
Augath, M.3
Trinath, T.4
Oeltermann, A.5
-
26
-
-
0033365133
-
Functional imaging of the monkey brain
-
Logothetis N.K., Guggenberger H., Peled S., Pauls J. Functional imaging of the monkey brain. Nat Neurosci 1999, 2(6):555-562.
-
(1999)
Nat Neurosci
, vol.2
, Issue.6
, pp. 555-562
-
-
Logothetis, N.K.1
Guggenberger, H.2
Peled, S.3
Pauls, J.4
-
27
-
-
13544268552
-
Anatomical and functional MR imaging in the macaque monkey using a vertical large-bore 7 Tesla setup
-
Pfeuffer J., Merkle H., Beyerlein M., Steudel T., Logothetis N.K. Anatomical and functional MR imaging in the macaque monkey using a vertical large-bore 7 Tesla setup. Magn Reson Imaging 2004, 22(10):1343-1359.
-
(2004)
Magn Reson Imaging
, vol.22
, Issue.10
, pp. 1343-1359
-
-
Pfeuffer, J.1
Merkle, H.2
Beyerlein, M.3
Steudel, T.4
Logothetis, N.K.5
-
28
-
-
77956884587
-
Baseline BOLD signal shift in macaque primary visual cortex (V1) after local application of acetylcholine
-
[in preparation]
-
Rauch A, Zhang X, Biessmann F, Meinecke F, Goense J, Muller KR, et al. Baseline BOLD signal shift in macaque primary visual cortex (V1) after local application of acetylcholine. 2010 [in preparation].
-
(2010)
-
-
Rauch, A.1
Zhang, X.2
Biessmann, F.3
Meinecke, F.4
Goense, J.5
Muller, K.R.6
-
29
-
-
77956873391
-
RF coils for whole head fMRI and MEMRI of primates and rodents in a vertical 4.7T and 7T scanner setup
-
[in preparation]
-
Augath MA, Beyerlein M, Logothetis NK, Merkle H. RF coils for whole head fMRI and MEMRI of primates and rodents in a vertical 4.7T and 7T scanner setup. 2010 [in preparation].
-
(2010)
-
-
Augath, M.A.1
Beyerlein, M.2
Logothetis, N.K.3
Merkle, H.4
-
31
-
-
0033653299
-
Impact of signal-to-noise on functional MRI
-
Parrish T.B., Gitelman D.R., Labar K.S., Mesulam M.M. Impact of signal-to-noise on functional MRI. Magn Reson Med 2000, 44(6):925-932.
-
(2000)
Magn Reson Med
, vol.44
, Issue.6
, pp. 925-932
-
-
Parrish, T.B.1
Gitelman, D.R.2
Labar, K.S.3
Mesulam, M.M.4
-
32
-
-
34249719407
-
Radio frequency coil technology for small-animal MRI
-
Doty F.D., Entzminger G., Kulkarni J., Pamarthy K., Staab J.P. Radio frequency coil technology for small-animal MRI. NMR Biomed 2007, 20(3):304-325.
-
(2007)
NMR Biomed
, vol.20
, Issue.3
, pp. 304-325
-
-
Doty, F.D.1
Entzminger, G.2
Kulkarni, J.3
Pamarthy, K.4
Staab, J.P.5
-
33
-
-
18044385764
-
Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters
-
Triantafyllou C., Hoge R.D., Krueger G., Wiggins C.J., Potthast A., Wiggins G.C., et al. Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters. Neuroimage 2005, 26(1):243-250.
-
(2005)
Neuroimage
, vol.26
, Issue.1
, pp. 243-250
-
-
Triantafyllou, C.1
Hoge, R.D.2
Krueger, G.3
Wiggins, C.J.4
Potthast, A.5
Wiggins, G.C.6
-
34
-
-
46849095682
-
Modular design of receiver coil arrays
-
De Zanche N., Massner J.A., Leussler C., Pruessmann K.P. Modular design of receiver coil arrays. NMR Biomed 2008, 21(6):644-654.
-
(2008)
NMR Biomed
, vol.21
, Issue.6
, pp. 644-654
-
-
De Zanche, N.1
Massner, J.A.2
Leussler, C.3
Pruessmann, K.P.4
-
35
-
-
0035091609
-
Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging
-
Kruger G., Kastrup A., Glover G.H. Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging. Magn Reson Med 2001, 45(4):595-604.
-
(2001)
Magn Reson Med
, vol.45
, Issue.4
, pp. 595-604
-
-
Kruger, G.1
Kastrup, A.2
Glover, G.H.3
-
36
-
-
34548813221
-
Mapping the MRI voxel volume in which thermal noise matches physiological noise - implications for fMRI
-
Bodurka J., Ye F., Petridou N., Murphy K., Bandettini P.A. Mapping the MRI voxel volume in which thermal noise matches physiological noise - implications for fMRI. Neuroimage 2007, 34(2):542-549.
-
(2007)
Neuroimage
, vol.34
, Issue.2
, pp. 542-549
-
-
Bodurka, J.1
Ye, F.2
Petridou, N.3
Murphy, K.4
Bandettini, P.A.5
|