메뉴 건너뛰기




Volumn 28, Issue 8, 2010, Pages 1244-1250

NMR at very low fields

Author keywords

Low field NMR; Relaxometry; SQUID

Indexed keywords

IMAGE ANALYSIS; IMAGE QUALITY; INTERMETHOD COMPARISON; MAGNETIC FIELD; NUCLEAR MAGNETIC RESONANCE; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; PRIORITY JOURNAL; RADIOFREQUENCY; REVIEW; TEMPERATURE SENSITIVITY;

EID: 77956871166     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2010.02.004     Document Type: Review
Times cited : (41)

References (22)
  • 1
    • 3042581653 scopus 로고
    • NMR field cycling spectroscopy: principles and applications
    • Noack F. NMR field cycling spectroscopy: principles and applications. Prog NMR Spectrosc 1986, 18:171-276.
    • (1986) Prog NMR Spectrosc , vol.18 , pp. 171-276
    • Noack, F.1
  • 2
  • 4
    • 0001554044 scopus 로고
    • Free nuclear induction in the Earth's magnetic field
    • Packard M., Varian R. Free nuclear induction in the Earth's magnetic field. Phys Rev 1954, 93:941.
    • (1954) Phys Rev , vol.93 , pp. 941
    • Packard, M.1    Varian, R.2
  • 5
    • 84891026021 scopus 로고    scopus 로고
    • Wiley, J. Clarke, A.I. Braginski (Eds.)
    • The SQUID handbook 2006, Wiley. J. Clarke, A.I. Braginski (Eds.).
    • (2006) The SQUID handbook
  • 6
    • 0032345068 scopus 로고    scopus 로고
    • Application of superconducting quantum interference devices to nuclear magnetic resonance
    • Greenberg Y.S. Application of superconducting quantum interference devices to nuclear magnetic resonance. Rev Mod Phys 1998, 70:175.
    • (1998) Rev Mod Phys , vol.70 , pp. 175
    • Greenberg, Y.S.1
  • 9
    • 84855874723 scopus 로고    scopus 로고
    • Nuclear magnetic resonance on room temperature samples in nanotesla fields using a two-stage dc superconducting quantum interference device sensor
    • Körber R., Casey A., Shibahara A., Piscitelli M., Cowan B.P., Lusher C.P., et al. Nuclear magnetic resonance on room temperature samples in nanotesla fields using a two-stage dc superconducting quantum interference device sensor. Appl Phys Lett 2007, 91:142501.
    • (2007) Appl Phys Lett , vol.91 , pp. 142501
    • Körber, R.1    Casey, A.2    Shibahara, A.3    Piscitelli, M.4    Cowan, B.P.5    Lusher, C.P.6
  • 11
    • 34548022858 scopus 로고    scopus 로고
    • Nuclear magnetic resonance in the Earth's magnetic field using a nitrogen-cooled superconducting quantum interference device
    • Qui L., Zhang Y., Krause H.J., Braginski A.I., Burghoff M., Trahms L. Nuclear magnetic resonance in the Earth's magnetic field using a nitrogen-cooled superconducting quantum interference device. Appl Phys Lett 2007, 91:072505.
    • (2007) Appl Phys Lett , vol.91 , pp. 072505
    • Qui, L.1    Zhang, Y.2    Krause, H.J.3    Braginski, A.I.4    Burghoff, M.5    Trahms, L.6
  • 12
    • 31444437341 scopus 로고    scopus 로고
    • Trahms L. J-coupling nuclear magnetic resonance spectroscopy of liquids in nT fields
    • Bernarding J., Buntkowsky G., Macholl S., Hartwig S., Burghoff M. Trahms L. J-coupling nuclear magnetic resonance spectroscopy of liquids in nT fields. J Am Chem Soc 2006, 128:714-715.
    • (2006) J Am Chem Soc , vol.128 , pp. 714-715
    • Bernarding, J.1    Buntkowsky, G.2    Macholl, S.3    Hartwig, S.4    Burghoff, M.5
  • 15
    • 15844389107 scopus 로고    scopus 로고
    • Liquid helium cryostat for SQUID-based MRI receivers
    • Seton H., Hutchison J.M.S., Bussell D.M. Liquid helium cryostat for SQUID-based MRI receivers. Cryogenics 2005, 45(5):348-355.
    • (2005) Cryogenics , vol.45 , Issue.5 , pp. 348-355
    • Seton, H.1    Hutchison, J.M.S.2    Bussell, D.M.3
  • 18
    • 17644399479 scopus 로고    scopus 로고
    • Image artifacts in very low magnetic field MRI: the role of concomitant gradients
    • Yablonskiy D.A., Sukstanskii A.L., Ackerman J.J. Image artifacts in very low magnetic field MRI: the role of concomitant gradients. J Magn Reson 2005, 174:279-286.
    • (2005) J Magn Reson , vol.174 , pp. 279-286
    • Yablonskiy, D.A.1    Sukstanskii, A.L.2    Ackerman, J.J.3
  • 20
    • 51349166190 scopus 로고    scopus 로고
    • Fluid flow characterization with nuclear spins without magnetic resonance
    • 092507
    • Crawford C.W., Xu S., Siegel E., Budker D., Pines A. Fluid flow characterization with nuclear spins without magnetic resonance. Appl Phys Lett 2008, 092507:93.
    • (2008) Appl Phys Lett , pp. 93
    • Crawford, C.W.1    Xu, S.2    Siegel, E.3    Budker, D.4    Pines, A.5
  • 21
    • 3442902841 scopus 로고    scopus 로고
    • MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT)
    • Bidinosti C.P., Choukeife J., Tastevin G., Vignaud A., Nacher P.J. MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT). MAGMA 2004, 16:255-258.
    • (2004) MAGMA , vol.16 , pp. 255-258
    • Bidinosti, C.P.1    Choukeife, J.2    Tastevin, G.3    Vignaud, A.4    Nacher, P.J.5
  • 22
    • 70249140913 scopus 로고    scopus 로고
    • Neuronal current detection with low field magnetic resonance: simulations and methods
    • Cassara A., Maraviglia B., Hartwig S., Trahms L., Burghoff M. Neuronal current detection with low field magnetic resonance: simulations and methods. Magn Reson Imaging 2009, 27:1131-1139.
    • (2009) Magn Reson Imaging , vol.27 , pp. 1131-1139
    • Cassara, A.1    Maraviglia, B.2    Hartwig, S.3    Trahms, L.4    Burghoff, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.