-
2
-
-
77956837984
-
-
EUROPYRO Beaune, France
-
B. Mahé, M. Tanguy, L. Minguet and B. Nouguez, Automated casting line for projectiles. EUROPYRO 2007, Beaune, France
-
(2007)
Automated Casting Line for Projectiles.
-
-
Mahé, B.1
Tanguy, M.2
Minguet, L.3
Nouguez, B.4
-
7
-
-
77956798079
-
-
12th International Detonation Symposium, San Diego, USA
-
S. Karlsson, H. Ostmark, C. Eldsäter. T. Carlson, H. Bergman, S. Walin and A. Pettersson, Detonation and sensitivity properties of FOX-7, 12th International Detonation Symposium, San Diego, USA, 2002
-
(2002)
Detonation and Sensitivity Properties of FOX-7
-
-
Karlsson, S.1
Ostmark, H.2
Eldsäter, C.3
Carlson, T.4
Bergman, H.5
Walin, S.6
Pettersson, A.7
-
8
-
-
0037170211
-
Nguanylurea-dinitramide: A new energetic material with low sensitivity for propellants and explosives applications
-
February (7).
-
H. Östmark U. Bemm, H. Bergmann and A. Langlet Nguanylurea- dinitramide : a new energetic material with low sensitivity for propellants and explosives applications, Thermochimica Acta, Volume 384, Number 125 February 2002. pp. 253-259 (7).
-
(2002)
Thermochimica Acta
, vol.384
, Issue.125
, pp. 253-259
-
-
Östmark, H.1
Bemm, U.2
Bergmann, H.3
Langlet, A.4
-
9
-
-
77956811479
-
-
Patent n° EP0581838. Elément peu vulnérable de munition explosive comportant un chargement explosif multicomposition et procédé d'obtention d'un effet de souffle/bulles.
-
Patent n° EP0581838. Elément peu vulnérable de munition explosive comportant un chargement explosif multicomposition et procédé d'obtention d'un effet de souffle/bulles.
-
-
-
-
10
-
-
77956845970
-
-
Patent n°EP0527054. Elément peu vulnérable de munition explosive comportant un chargement explosif bicomposition et procédé d'obtention d'un effet d'éclats
-
Patent n°EP0527054. Elément peu vulnérable de munition explosive comportant un chargement explosif bicomposition et procédé d'obtention d'un effet d'éclats
-
-
-
-
11
-
-
77956799345
-
-
a ISGT stands for Intermediate Scale Gap Test : a confined F40 mm-L200mm substance acceptor is stimulated by a F40-L 40 mm RDX/Wax (95/5,1.6 indensity) donor. The number of acetate cards (0.19 mm in thickness) under which no detonation is obtained, is the measure of the shock sensitivity of the acceptor substance.
-
a ISGT stands for Intermediate Scale Gap Test : a confined F40 mm-L200mm substance acceptor is stimulated by a F40-L 40 mm RDX/Wax (95/5,1.6 indensity) donor. The number of acetate cards (0.19 mm in thickness) under which no detonation is obtained, is the measure of the shock sensitivity of the acceptor substance.
-
-
-
-
12
-
-
77956808616
-
-
b ELSGT stands for Expanded Large Scale Gap Test : a confined F73.2mm-L279mm substance acceptor is stimulated by a F95.3-L47.6mm RDX/Wax (95/5.1.6 indensity) donor. The thickness of the PMMA barrier under which no detonation is obtained, is the measure of the shock sensitivity of the acceptor substance.
-
b ELSGT stands for Expanded Large Scale Gap Test : a confined F73.2mm-L279mm substance acceptor is stimulated by a F95.3-L47.6mm RDX/Wax (95/5.1.6 indensity) donor. The thickness of the PMMA barrier under which no detonation is obtained, is the measure of the shock sensitivity of the acceptor substance.
-
-
-
-
13
-
-
77956844726
-
-
c EIDS stands for Extremely Insensitive Detonating Substance
-
c EIDS stands for Extremely Insensitive Detonating Substance
-
-
-
|