메뉴 건너뛰기




Volumn , Issue , 2003, Pages 124-128

Frequency converter influence on induction motor rotor faults detection using motor current signature analysis-experimental research

Author keywords

Bars; Current measurement; Fault detection; Fault diagnosis; Frequency conversion; Induction motors; Performance evaluation; Rotors; Stators; Testing

Indexed keywords

BARS (METAL); ELECTRIC CURRENT MEASUREMENT; ELECTRIC DRIVES; ELECTRIC FAULT CURRENTS; ELECTRIC MACHINERY; FAILURE ANALYSIS; FREQUENCY CONVERTERS; GEARS; INDUCTION MOTORS; OPTICAL FREQUENCY CONVERSION; POWER CONVERTERS; POWER ELECTRONICS; ROTORS; ROTORS (WINDINGS); STATORS; TESTING;

EID: 77956748800     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/DEMPED.2003.1234559     Document Type: Conference Paper
Times cited : (9)

References (13)
  • 5
    • 0035396689 scopus 로고    scopus 로고
    • Current Signature Analysis to Detect Induction Motor Faults
    • July/August
    • Thomson W T., Fenger M., "Current Signature Analysis to Detect Induction Motor Faults", IEEE Industry Applications Mag., Vol. 7, No. 4 July/August 2001, pp. 26-34
    • (2001) IEEE Industry Applications Mag. , vol.7 , Issue.4 , pp. 26-34
    • Thomson, W.T.1    Fenger, M.2
  • 6
    • 28744439549 scopus 로고    scopus 로고
    • Cause and Analysis of Stator and Rotor Failures in Three-Phase Squirrel-Cage Induction Motors
    • vol.
    • Bonnett A. H., Soukup G. C., "Cause and Analysis of Stator and Rotor Failures in Three-Phase Squirrel-Cage Induction Motors", IEEE Trans. on Indust. Applic., vol.
    • IEEE Trans. on Indust. Applic.
    • Bonnett, A.H.1    Soukup, G.C.2
  • 8
    • 84947260132 scopus 로고    scopus 로고
    • Rotor Cage Fault Diagnosis in Operating Three-Phase Induction Motors, Under the Presence of Time-Varying Loads
    • Cruz S.M.A., Marques Carsodo A.J., "Rotor Cage Fault Diagnosis in Operating Three-Phase Induction Motors, Under the Presence of Time-Varying Loads", EPE 2001, Graz.
    • EPE 2001, Graz
    • Cruz, S.M.A.1    Marques Carsodo, A.J.2
  • 9
    • 84947203517 scopus 로고    scopus 로고
    • The Advanced Method of Rotor Failure Detection in Large Induction Motors
    • Lazarević Z., Petrović D., "The Advanced Method of Rotor Failure Detection in Large Induction Motors", CIGRE 2000, 11-203
    • CIGRE 2000 , pp. 11-203
    • Lazarević, Z.1    Petrović, D.2
  • 11
    • 0003196050 scopus 로고    scopus 로고
    • A Review of On-Line Condition Monitoring Techniques for Three-Phase Squirrel-Cage Motors - Past Present and Future
    • Thomson W. T., "A Review of On-Line Condition Monitoring Techniques for Three-Phase Squirrel-Cage Motors - Past Present and Future", IEEE SDEMPED '99, Spain, Sept. 1999., pp. 3-18.
    • IEEE SDEMPED '99, Spain, Sept. 1999 , pp. 3-18
    • Thomson, W.T.1
  • 12
    • 0024121951 scopus 로고
    • Noninvasive Detection of Broken Rotor Bars in Operating Induction Motors
    • December
    • Klinman G. B., Koegl R. A., "Noninvasive Detection of Broken Rotor Bars in Operating Induction Motors", IEEE Transactions on Energy Conversion, Vol. 3, No. 4, December 1988, pp. 873-879.
    • (1988) IEEE Transactions on Energy Conversion , vol.3 , Issue.4 , pp. 873-879
    • Klinman, G.B.1    Koegl, R.A.2
  • 13
    • 0031099505 scopus 로고    scopus 로고
    • Direct Torque Control, Induction Motor Vector Control Without an Encoder
    • March/April
    • Nash N. J., "Direct Torque Control, Induction Motor Vector Control Without an Encoder" IEEE Transactions on Industry Applications, Vol. 33, No. 2, March/April 1997.
    • (1997) IEEE Transactions on Industry Applications , vol.33 , Issue.2
    • Nash, N.J.1