메뉴 건너뛰기




Volumn 52, Issue 3, 2010, Pages 1170-1171

Twelve-week posttreatment follow-up predicts a sustained virological response to pegylated interferon and ribavirin therapy

Author keywords

[No Author keywords available]

Indexed keywords

PEGINTERFERON ALPHA2A; RIBAVIRIN; VIRUS RNA; ALPHA INTERFERON; ALPHA2A INTERFERON; ALPHA2B INTERFERON; ANTIVIRUS AGENT; MACROGOL DERIVATIVE; PEGINTERFERON ALPHA2B; RECOMBINANT PROTEIN;

EID: 77956625537     PISSN: 02709139     EISSN: 15273350     Source Type: Journal    
DOI: 10.1002/hep.23685     Document Type: Letter
Times cited : (9)

References (4)
  • 1
    • 77950597305 scopus 로고    scopus 로고
    • Twelve weeks post-treatment follow-up is as relevant as 24 weeks to determine the sustained virologic response in patients with hepatitis C virus receiving pegylated interferon and ribavirin
    • Martinot-Peignoux M, Stern C, Maylin S, et al. Twelve weeks post-treatment follow-up is as relevant as 24 weeks to determine the sustained virologic response in patients with hepatitis C virus receiving pegylated interferon and ribavirin. HEPATOLOGY 2010;51.
    • (2010) Hepatology , pp. 51
    • Martinot-Peignoux, M.1    Stern, C.2    Maylin, S.3
  • 2
    • 72249083270 scopus 로고    scopus 로고
    • Randomized study of peginterferon-alpha2a plus ribavirin vs peginterferon-alpha2b plus ribavirin in chronic hepatitis C
    • Rumi MG, Aghemo A, Prati GM, D'Ambrosio R, Donato MF, Soffredini R, et al. Randomized study of peginterferon-alpha2a plus ribavirin vs peginterferon-alpha2b plus ribavirin in chronic hepatitis C. Gastroenterology 2010;138:108-115.
    • (2010) Gastroenterology , vol.138 , pp. 108-115
    • Rumi, M.G.1    Aghemo, A.2    Prati, G.M.3    D'Ambrosio, R.4    Donato, M.F.5    Soffredini, R.6
  • 3
    • 0032947751 scopus 로고    scopus 로고
    • Second generation of the automated Cobas Amplicor HCV assay improves sensitivity of hepatitis C virus RNA detection and yields results that are more clinically relevant
    • Doglio A, Laffont C, Caroli-Bosc FX, Rochet P, Lefebvre J. Second generation of the automated Cobas Amplicor HCV assay improves sensitivity of hepatitis C virus RNA detection and yields results that are more clinically relevant. J Clin Microbiol 1999;37:1567-1569. (Pubitemid 29187836)
    • (1999) Journal of Clinical Microbiology , vol.37 , Issue.5 , pp. 1567-1569
    • Doglio, A.1    Laffont, C.2    Caroli-Bosc, F.X.3    Rochet, P.4    Lefebvre, J.-C.5
  • 4
    • 0032915574 scopus 로고    scopus 로고
    • Quantification of hepatitis C virus by TaqMan PCR: Comparison with HCV amplicor monitor assay
    • DOI 10.1002/(SICI)1096-9071(199906)58:2<121::AID-JMV4>3.0.CO;2-4
    • Kawai S, Yokosuka O, Kanda T, Imazeki F, Maru Y, Saisho H. Quantification of hepatitis C virus by TaqMan PCR: comparison with HCV Amplicor Monitor assay. J Med Virol 1999;58:121-126. (Pubitemid 29226853)
    • (1999) Journal of Medical Virology , vol.58 , Issue.2 , pp. 121-126
    • Kawai, S.1    Yokosuka, O.2    Kanda, T.3    Imazeki, F.4    Maru, Y.5    Saisho, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.